HomeMy WebLinkAbout018-2019-46-000Wisconsin Department or Commerce PRIVATE SEWAGE SYSTEM
Safety and Building Division
INSPECTION REPORT
GENERAL INFORMATION (ATTACH TO PERMIT)
Personal information you provide may be used for secondary purposes [Privacy Law, s.15.04 (1)(m)].
Permit Holders Name: City Village Township
Rollinq Hills Farm Owners Associatiorn I TOWN OF HAMMON
CST BM Elev: Insp. By Elev: BM Description
I o6e . 2 � ®ed ,�
TANK INFORMATION ELEVATION DATA
TYPE
MANUFACTUREF
KK ,LC.
CAPACITY
Septic
Dosing
C
' L G y.�(- Lr•J a�+ a� l
W7
7
I [_� U
Aeration
•;acr
Z Sir,�c1L i
TANK SETBACK INFORMATION
TANK TO
P/L
WELL
BLDG.
Ventto Airintake
ROAD
Septic
Dosing
Z-7
/V
of
Na
Aeration
Holding
PUMPISIPHON INFORMATION Per 01t, ir, 75.g2
Manufacturer
G bu I J�
Demand
GPM
Tqj
Model Number
(9
6q
TDH
Lif�
Friction Loy
1
System HgadC L
'1 J l
T H • ��Ft
Forcemain
Length 8 t Dia. r .
Distto well AA
SOIL ABSORPTION SYSTEM
I,..,ly St. Croix
Tax No:
018-2019-46-000
ioe/Mao No:
b8.75 If
17,124�6j
9 e."ZQ
Z
STATION
5 B�L
107.
1
J FS
l
'E� g
Benchmark
Q�
O•c('�P
.�'
y�
f�.Z93
Alt. BM
Bldg. Sewer
owa�„
r
�.
I •i
St/Ht Inlet
SVHt Outlet
Dt Inlet
Dt Bottom
I3
rO ba '
Header/Man.
-7 -7
'
Dist. Pipe
few
Bot. System
3.
Final Grade
St Dgyer
WOW
BED/TRENCH
DIMENSIONS
Width )n•'),
C
Len th
1 H
,
tie.OEi Ches q f%4
(-/
PIT DIMENSIONS
No. Of Pits
Inside Dia.
Liquid Depth
SETBACK
SYSTEM TO
JPIL
JBLDG
IWELL
LAKE/STR
LEAC NG
Ma rer:
INFORMATION
Type Of System
J
/1
AA
V
C AM R OR
IT
octal NurMer
DISTRIBUTION SYSTEM
_
Header/Manifold , r
�) t I
-1
Distribution s , ' t `
Pipe(s)��(� t?�
(9 0 -•
x Hole Size „
x Hole Spacing `
�'
Vent to Air Intake
'1'1 rvi Ii
-z•�
Length Dia
Length •V Cis Spacing I
1
SOIL COVER x Pressure Systems Only xx Mound Or At -Grade Systems Only rg, )') u IiIi
n a
BedRrerlcf(Center
J
Depth Over `�
Bed/Trench Edges 7) Z
xx Depth of ��
Topsoil I '2
m Seeded/Sodded
i'�I Yes ❑ No
xx Mulched
$'Yes rr No
`O
COMMENTS: (include code discrepancies, persons present, etc.)
Location: 740 161ST STcL 0�,�5 4 Ck 4',h`j
1.) Alt BMIDescription - yq j -� L i �
2.) Bldg sewer length = C por 4mvri� / 5.P7 C1-
- amount of cover = l,2VLF' / Q9 t yts yCC4-1 tg+q
Plan revision Required? ❑ Yes No
Use other side for additional informatio .
SBD-6710 (R.3/97)
Inspection
s#1.:2`sf`Z,O I� Inspection #2:
3i.��P•( b(a� L w pAJ&)
(� Ib K l Doi S
Date Insepctor' igna ure Cen. No.
�U1
—=% rF-11 rF—
SflVV-ao11— 01-1 S
Safety and Buildings Division
County/
St.Croix
75 -
I AUG 27 2019
201 W. Washington Ave., P.O. Box 7162
Sanitary Permit Number (to be filled in by Co.)
sf ;•,_�
Madison, W 707 16
•/ /�/7
5r.. r.rcix Coun[y
-- eYlTtlt Applimion
Sate Trmemetian Number
061901466-C
In accordance with SPS 35321(2), Wis. Adm. Code, submission of this form to the appropriate govenmntd eit
Address (jdff ing address)
is required prior to obtaining a sanitary permit. Note: Application forms for state-owned POWTS are submitted to
the Department of Safety and Professional Se ws. Personal information you provide may be used for secondary
purposes in accordance with the Privacy Law, a. 15.
L A tioa foformation - Please Print A
Property Owner's Name
Parcel a
Rolling Hills Farm Owners Association Inc
018-2019-401:000
Property Owner's Mailing Address
Property Location dj, R 1. 17.
3435 Labore Rd.STE 150
Gott. Lot ray 6
A SW '/., Section 29
City, State
ZiPCode Phone
Number
Vadnais Heights Mn
29 (c le One)
T Ni R 77 F orrt4
11. Type of Building (check all that ap Lot
#
Subdivision Name
❑ 1 or 2 Family Dwelling -Number of 12
t, Z.
3, apWA Block
Rolling Hills Farm
❑ Public/Commerctat - Describe Use
❑City of
❑ Sate Owned Describe Use/ / CSM
❑ Village of
Ig Town of 1lalnmorld -
Number
S �
ID. T
it only one box on line A. Complete line B if applicable)
iQ New System
Replacement System
❑ Tremment/Holding Tank Replacement Only
❑ Other Modification to Existing System (explain)
B.
❑ permit Renewal
❑ Permit Revision
❑ Change of Plumber
❑ Permit Transfer tc New
List Previous Permit Number and Date Issued
Before Expiation
Owner
TV. Type of POWTS m/Com Chwk aY that a
❑ Non -Pressurized hec oumd ❑ Pressurized hrGround ❑ At )❑ Mound>_ 24 m. of suitable soil ❑ <24 in of suitable soil
❑ Holding Tadr ❑ Dispersal Compoumt (explaw) Pretreatment Devi« (explain)
V. Dispersis VI'ra ant Ara Iaforma ' R r
Deign Flow (gpd) Design Sod Appl Rme(MM
Aspensel wnlrr� (sf)
Duspersal Meer s0
%i
System Elevation
1800 1.6
1000 1'2101
1128
1464:.28'106j, .��
VL Tank Info
Capacity in
Gallons
Tout
Gallons
N of
Units
mmufachmr
Sim Tec Filters
p
,2
a
g
g p
$$
2
New Task.
Fyimag Tads
Septic or Folding Task
o°ongChamber
1250
1250
WipaserConcrete
x
VD. Reaponsibi&y Statemeot- L lie madereigned, ante Si far . m of the POWTS Aamne on the attached plain
Plmlices Name (Print)
's Si
. MP/MPRS Number
Business Phone Number
Keith Knudtson
,
648443
651470-1737
Plumber's Addrea (Street, City, Stele, Zip Code)
927 150th St. Roberts Wi 54023
VUL County/Department Use Only
pproved
❑ D'
Permit Fee
i
fw �6
Date a
Issu ing Sigoanne
`
13
van Rcason for
/
IX. Cond' ea sons for Dsapproval
BCvl. 3 Geik
ep is nka ,I r r
ttLMl) _
�,�r„ic I wai ull �vaJf,:§1ia:7i: e'Sn t�r1)fVK_t�f— fwJ
0
- s per-tarayaman' plan p to IIt16H'4M Nlu,nbp;.
2. All ae!ba k ncUrA nhA Pn�il lu Tr„ tidf €a n
Y r b.
per ttppkillbll C161 4J`&"AiMf 4 o d5'
Attach to complete plans for the system and subddl b the Comy only on paper Bel lei 7 Mx
SBD-6398 (IL 11/11)
1
San&ary Slte Plan
i Fob^: `7yme Pe'pertfss,�LC
4ing.0411s :Farm C tjot 2
,iidi`'a' 46,4 Part oj, the 3W1/4
Town of 1 mmO,, YSt. Croix County
rS SSgs N87°08'43"E 180.52'a�
<O 6r8F Page 2af9�y
\°
so �0l
NSgssreR9
fro,: Sr
0� 75r5g40"C ` 8M ELEV.
N 1075.8E
• WELL
DWF = 600 gpd Hoot 1-14 0
Bw/septic
FH8744 LOT 48 �.
21,781 SQ. FT. 4" Sch. 40 PVC
Z "" . WELL
DWF = 600 gpd
161 t St FH4742 LOT 47
21.781 SQ, FT.
• WELL
740 DWF = 600 gpd
it 15
6 LOT Q4. 8FT8121,7S
C35-39.Vq 243.89.
I II
45
1072.48'
Hoot H-B00
Bfo/Sepiw
Sch 4040 PVC ,
in lr
Hoot "-am V
Blo/Septic
Bch. 40 PVC
Proposed Wieser Concrete �P"
WLP1250-MR w/ Duplex Pump
w/ Sumach STF-100 Filters
P1'82082
Top of Wood Hub q
Elm - 1000'
Is==1073.64' `
of pipe - 1067.64' J�
0 30 50
Graphic Inch —p' li') I
OUTLOT 2
42.71 ACRES
1,860,369 SQ. FT.
DWF of 1800 gala. /1.60 = 1126 sq. 8- /88. = 141 8.N
Lots 46-48
Typical of each lot will be 4• Sch. 40 PVC Bldg. Sewer
4" Sch. 40 PVC or Astm D-3034 PVC Conveyance Pipe.
8 Proposed Duplex 2" Sch. 40 PVC F.M,'s
1[1 PTB 2084
op of Wood Hub
:;A
ofAnt Elev.-1069,53'
B2-L46 1067.28'
1�1065.28'
1064.28'
l066 ,2
1 1062,28'
OAD02
U
Site is an open slope
w/a few small trees.
Proposed 6.0' x 141' Mound Dispersal Cell
located along the 1084.28 contour w/a
System Elev. of 1065.1 V
August 15, 2019
CONDITIONAL APPROVAL
PLAN APPROVAL EXPIRES: 2021-08-15
Plan Review: PWTS-081901486-C
KEITH E STONER
23220 Woodcreek Rd
Siren WI 54872
SITE: 1111141gmbjWWW"6 0.
740-744 161st St.
Town of Hammond
Saint Croix County
Total Amount: $325.00
DIVISION OF INDUSTRY SERVICES
2331 SAN LUIS PL
GREEN BAY WI 54304-5211
Contact Through Relay
http:lldsps.YA.gov/pWranrAridustry-serAoes
www.wisconsin.gov
Tony Evers - Governor
Dawn Crim - Secretary
Pressure Distribution Component Manual — Ver 2.0,
SBD-107606-P (N.01/01, R 10/12)
Mound Component Manual — Ver. 2.0, SBD-10691-P
(NA1/01, R 10/12)
Descr4o0on: 1800 GPD (12 Bedrooms — New Construction - Predeannent)
Maintenance Required
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes
and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This system is to be
constructed and located in accordance with the enclosed approved plans and with any component manual(s)
referenced above. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance
with all code requirements.
No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06,
stats.
The following conditions shall be met during construction or installation and prior to occupancy or use:
• SPS 383.54(I)(e) The management plan for a POWTS shall specifically address the servicing mechanics of an
aerobic or anaerobic treatment tank or a holding tank where either of the following conditions exist:
1. The bottom of the tank is located more than 15 feet below the elevation where the servicing pad is located.
2. The bottom of the tank is located more than 150 feet horizontally from where the servicing tad is located.
• Preserve dispersal area prior and during construction to avoid disturbance, compaction and use of the site.
• With new construction; it is recommended not to activate the pump in the dose tank until the tanks are
pumped prior to homeowner occupancy.
• Wastewater generated from contractors cleaning of equipment and tools and/or left over construction
products shall not be discharged into the drains discharging to the private onsite wastewater treatment system
(POWTS). Waste generated shall be properly disposed of on -site or off site.
• Any tall grasses, leaves and shrubs shall be cut short and removed prior to tilling the surface for installation to
prevent matting under the dispersal area. All loose organic material to be removed from mound area.
• Divert surface water from POWTS Area.
• Prior to construction of the dispersal area, check the moisture content of the soil to a depth of 8 inches.
Smearing and compacting of wet soil will result in reducing the infiltration capacity of the soil. Proper soil
moisture content can be determined by rolling a soil sample between the hands. If it rolls into a 1/4- inch wire,
the site is too wet to prepare. If it crumbles, site preparation can proceed. If the site is too wet to prepare, do not
proceed until it dries.
• All piping shall conform to SPS Table 384.30-3 and SPS Table 384.30-5
• Insulate building sewer beyond 30 feet per SPS 382.30 (11)(c)
• Well setbacks to meet chs. NR 811 & 812
• Tank Installation to follow all manufacture's recommendations.
• SPS 383.54(I)(e) The management plan for a POWTS shall specifically address the servicing mechanics of an
aerobic or anaerobic treatment tank or a holding tank where either of the following conditions exist:
1. The bottom of the tank is located more than 15 feet below the elevation where the servicing pad is located.
2. The bottom of the tank is located more than 150 feet horizontally from where the servicing pad is located.
• Verify property line(s) prior to installation.
• Pump Floats to be set and verified per approved plan. Any changes may result in pump resmng to meet
TDH and GPM Specifications.
• Areas that are occupied with rock fragments, tree roots, stumps and boulders reduce the amount of soil
available for proper treatment. If no other site is available, trees in the basal area of the mound must be cut off
at ground level. A larger fill area is necessary when any of the above conditions are encountered, to provide
sufficient infiltrative area.
Owner Responsibilities
• The current owner, and each subsequent owner, shall receive a copy of this letter including instructions relating
to proper use and maintenance of the system. Owners shall receive a copy of the appropriate operation and
maintenance manual and/or owner's manual for the POWTS described in this approval SPS 383.54(1).
• In the event this soil absorption system or any of its component parts malfunctions so as to create a health
hazard, the property owner must follow the contingency plan as described in the approved plans.
A copy of the approved plans, specifications and this letter shall be on -site during construction and open to
inspection by authorized representatives of the Department, which may include local inspectors. All permits
required by the state or the local municipality shall be obtained prior to commencement of
construction/installation/operation.
In granting this approval the Division of Industry Services reserves the right to require changes or additions should
conditions arise making them necessary for code compliance. As per state stats I01. 12(2), nothing in this review
shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address
on this letterhead.
The above left addressee shall provide a copy of this letter and the POWTS management plan to the owner and any
others who are responsible for the installation, operation or maintenance of the POWTS.
Sincerely,
�/nc�,e n 7/.aw✓.tA o�
Tim Vander Leest
Private Sewage Plan Reviewer, Division of Industry Services
(920)I92-2214 , Mon- Fri, 6:00 a.m. - 3:30 p.m.
tim.vandericest@wi.gov
Index and Title Sheet
Project Name: Rolling Hills Farm Shared Sanitary System for Lots 46-48 Ur
Property Owner: Tyme Properties LLC
Address: 3435 Labore Rd.
Vadnais Heights MN 55110 t., t —t
Legal Description: Part of the SW 'A
Section 29T29N-R17W
Township: Hammond County: St. Croix
Subdivision Name: Rolling Hills Farm Outlot 2 Lots: Sanitary System Serving Lots 46-47 and 48
Comp. #/Parcel ID: 018-201946-000 — 018-2019-48-000
CONTENTS
Page: I Plan Narrative
Page: 2 Plot Plan
Page: 3 Mound Plan View and Cross Section
Page: 4 Lateral Layout
Page: 5 Dose Chamber Cross -Section
Page: 6 Pump Curve
Page: 7 a+b Duplex Pump Panel Specifications
Page: 8 Hoot Systems H-600A Tank Specs. and Hoot Service and Inspection Form
Page: 9 Management and Contingency Plan
Attachments: Soil and Site Evaluation Reports, Sample ATU Servicing Agreement and Hoot
Systems LLC Product Approval with maintenance requirements.
Mound Component Manual Used = Version 2.0 SBD-10691-P (N.01/01R. 10/12)
Pressure Distribution Component Manual Version 2.0 SBD-10706-P (N 01/01 R. 10/12)
"�tUUtHt11lIIi
Designer: Keith E. StoROi�ONNN� License # Designer 157-007
Signature: at 7-18-19 Phone # (715) 653-2324
W5.
(J'
Sankary Site Plan
\\�U
For; Tyme Properties„4LC
Rolling Hills Farm OuClot 2
Lots 46-48 Part of the SW114
o
Sec. 29 T29N-R17W
o
Town of Hammond - St. Croix County
Z \
'34 N75°58401E23261 BM ELEV.
'1
�
1075.88
• WELLSp
" t
DWF = 600 gpd
Hoot H-e00
1
Biolsepdc p
, Am
W FN# 744 LOT 48
�
21,761 $Q. FT. 4" Soh. 40 PVCit
\wj
072.80' Nyd
O_
9.77
34'D2 M123'
wp
WW
• WELL
1072.48
DWF = 600 gpd
Hoot H-600
Bolseptic
St. I'M742 LOT 47
1161�t
4" Sch, 40 PVC
21,781 SQ. FT.
• WELL r.
740 Hoot H-600
DWF = 600 gpd Blo/Sept
1
LOT 48 4"6oh PVC
1064.3
21,781 SO. FT.
Proposed Wieser Concrete
3919W243-89 WLP1250-MRw/Duplex Pumps
w/ Simtech STF-100 Filters
OT 45
06. N 7008ATE 160.52'
b�
7S�0 S6rtQ' Page 2 of 9 h�
T F 0
NSyS6 �g9 S� 000, moo, �O`1O
7g$7
0 3D 80
b
1 lnM - 1r 0f .
q� 5
PIN 2082
Top ofWoud Hub 'R
Elev 1061.69' n
OUTLOT 2
42.71 ACRES
Is =1073.B4' 1,860,359 SO. FT.
of pipe = 1067.64' 4f
DWF of 1800 gals. /1.60 = 1125 sq. ft. /8ft. = 141 ft.N
Lots 46-48
Typical of each lot will be 4" Sch. 40 PVC Bldg. Sewer
4" Sch. 40 PVC or Astm D-3034 PVC Conveyance Pipe.
t Proposed Duplex 2" Sch. 40 PVC F.M.'s
tri PT# 2084
Top of Wood Hub
Top of Wood Hub w Elev. = 1068.53'
B2-L48 Elev.=1068.28 Bi-L48 O 1067.28'
1 1 1065.28'
1064.28'
B3-L48 11062
1066.34' I •� 1062.28'
--..
Site is an open slope
w/a few small trees.
Proposed 8.0' x 141' Mound Dispersal Cell
located along the 1 D64.28 contour w/a
System Elev. of 1065.1 V
Mound Plan View
L
Mound component Dimensions
A 8.1Y E 20.5 "
B 1 1' F
D 10" G 6"
1128 (ft sq.) Dispersal Cell Area
12.76 (MxVft) Li— Loading Bsr[
Page 3 of-9
H 12" K 920'
1 L 159.40'
J 4.78' W 26.21'
3 ((t•) Basal Area Available
14.1 (ft) 1110 B Obs. Pipe Placement
Mound Cross Section View
Aggregate Dispersal Area
i)� �� — i as • _ �
Cell
Elevation
Shading Key
® Topsoil Cap
® Subsoil Cap
ASTM C33 Sand
® Tilled Layer
® Aare8ate
11 % Site Slope
observation Pipe to be constricted of 4" diam.
pipe w/ water tight cap, a minimum 6" slot
anchored with 3/8" rebar or a water closet collar.
Detail of .
Typical Dispersal Cell
4 A
G
_IH
OL65
1 Invert
Lateral
Invert
(lt) Contour Elevation
%tile Fabric
Cover
Page 4 of 9
Center Connection Duplex Manifold
Lateral Layout Diagram
ft. X "I t.94 ft.
P F P
Note: F.M. attached to Laterals and Force Main of PVC Sch. 40
center of the manifold. per SPS Table 384.30-5
S 5%
ft� 1 — -.94 ft.—
Turn-up w/ball valve or clean
out plug
Number of Laterals
Lateral Diameter
Lateral Length (P)
Lateral Spacing (S)
Lateral Flow Rate
1/2 Cell Flow Rate
System Flow Rate
Total Dynamic Head
X X Holes equally spaced on
bottom of lateral
Duplex Force Main Note: Forcemains coming into the center of cell, 1 st
hole approx. 1.25' from the manifolds maintaining
14 the 3.00' hole spacing. Northwest manifold + F.M.
.25 ft. feed north 1/2 of cell and same for the southeast F.M.
2 per F.M. +manifold.
1 1/2
68.08
4.00
12.96
25.92
51.84
14.54
in.
fL
M
orifice
ft.
in.
ft.
Lateral Turn -up Detail
in.
Orfice Diameter
ft.
Orifice Spacing (X)
ft.
Orifices per Lateral
gpm
Orifice Density
gpm
Manifold Length
gpm
Manifold Diameter
ft
Forcemain Diameter
and Length
5/32 or 0.156
2.96
24
11.75
4.00
1.5
2"/80' per F.M.
Finished Grade Threaded Cleanout Plug or Ball
6" to R" diameter Lawn Sprinkler Box � Valve
� V
Note: Lateral ends at last orifice where variable
length to cleanout begins.
Long Sweep 90 or Two 45' Bends Same
Diameter as Lateral
Distribution Lateral
Page 5 of 9
Duplex Pump DoseTank Component Cross Section
Approved Manhole Covers With Warning Labels
and Locking Device / 4" Min. Above Final Grade
Weather Proof Junction Box
Electric per NEC 300 dt SPS
4" Sch. 40 Vent 316.012 WAC
> or = to 12"
Above Final Grade n
Note: SJE Rhombus Type 122Duplex I I I L Alternate Outlet Location
Demand Dose f W/A roved 4" Sleeve
Top of inlet=1060.34' 1 11 1 1 1 Force Main Diam. = 2 "
or Anti Siphon Device
Note: Pump switch and alarm to be A uplex Force Mains
wired to separate circuits. r ��
B pump Off Elev. 1057.67
WLP1250-MR Gallon C Duplex Pumps
Tank Mfr. Wiesert Concrete
L r ----'ll Dose Tank Elev. 1056.84'
Vertical Difference Between Pump Off and Distribution Pipe = 7.94' Per 1/2
Minimum Required Supply Pressure ...................................... = 4_55 of cell
80' FT. of Force Main x 1.94 Friction Factor/100FT.... = 1.55' per dose
Note: Maximum dose per Pressure Loss Through Filter ................... _ .50'
F.M. or 1/2 cell equals 180 gals. Total Dynamic Head ............. _..... = 14.54' • 55
Min. dose per 1/2 cell = 62.63 gals.
Number of Doses...— 965 Per Day Gal. Per Day/ #of Doses = 121.OlGal. (Duplex
Volume of Backflow.......................................................... _... _... = 13.04 Gal. PumpsAltemaling
Total Dose Volume..................................................................... = 134.05Gal. between 112 of
cell)
Pump Tank Capacity 1260.07 Gallons Dimensions Inches Gallons
Pump Tank Volune 26_81 Gal/loch A 30 804.30 Note: Tank to have
B 2 53.62 two outlets.
Pump Mfr. Goulds C 5 134.05 Note: Force main
Pump Model EP04 D 10 268. 00 lengths should be
Minimum Discharge Rate = 25.92 GPM per pump nearly the same
length.
Alarm Mfr. S.J.E. Rhombus Total— 47.00 1260.07
Alarm Model Tank Alert I
Bed Tank per SPS. 383.45(5)
N Anchor Tank as necessary to negate buoyant forces per SPS 383.43(8xg).
ewate r
METERS FEEL
10
9 31
8
2!
7
x
U 6 21
2 5
0 1'
J 4
H
Q
3 11
2
1
0
Pace 6 of 9
__. -____
I
_.�...__ SGPM
t—_.
!
t
I
1
i
i
I
1
I 3
--
--
-?--- -
-
---
- a-
EPOS -- '
!
I
0�
10 ZO 30 40 W "I'M
0 2 4
WT7-T--A-kl
10 12
Order
Minimum
Float
Cord
Discharge
Minimum
Minimum
Mhrimum
Maxhnum
Shipping
Number
RP
V.W
Amps
Crcuit
Phase
SVvI"
On Level
OffLevel
Basel
solids
Weight
Break.
styleConnection
Diameter
Size
lbs.kg
EP0411
.4
115
12
20
1
No Switch
10'
1W
Manual
Manual
15"
Y."
20/9.1
EP0411A
Piggyback/
Wide -Angle.
10,
12'
6.
21 /9.5
EMN11F
Nolug/
20'
Manual
Manual
20/9.1
EP0411AC
Piggyback/
Wide -Angle
20,
12"
6'
21 /9.5
EP0412
230
6
f0
Plug t
Switch
Sv
10,
Manual
Manual
20/9.1
EP0412F
Plus /
No Switch
20'
Manual
Manual
20 / 9.1
EP0511F
.5
11S
13
20
No
20
Manual
Manual
22/10
EP0511AC
Piggyback /
Wide -Angle
20'
12"
6-
23 / 10.4
EP0512F
230
6.5
10
No Plug
Swi
20-1-Manual
Manual
22/10
PAGE 3
Single phase, duplex alternating pump control with override. Fria 7 a+D of 9
The Model 122 control panel is designed to alternately control two 120, 208, or 240 VAC single phase pumps in water and sewage
installations. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override
control should either pump fail. If an alarm condition occurs, an alarm switch activates the audiovisual alarm system. Common
applications include pump chambers, sump pump basins, irrigation systems and lift stations.
1. Enclosure measures 10 X 10 X 6 inches (25A X 25A X 15.24 cm).
Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized
thermoplastic with removable mounting feet for outdoor or indoor use).
Note: Options selected may increase enclosure size and change component
layout.
2. Magnetic Motor Contactors control pumps by switching electrical lines.
3. HOA Switches for manual pump control (mounted on circuit board).
4. Control Circuit Board provides pump control and ahemation.
5. Green pump Run Indicator Lights (mounted on circuit board).
6. Circuit Breakers (optional) provide pump disconnect and branch circuit
protection.
7. Ground Lugs
8. Float Status Indicator Lights (mounted on circuit board).
9. Control and Alarm Power Indicator Lights (mounted on circuit board)
10. Auxiliary Alarm Contact, form C (mounted on circuit board).
NOTE: Schematic is located inside the panel on enclosure cover.
STANDARD ALARM PACKAGE
11. Red Alarm Beacon provides 360' visual check of alarm condition.
Note: NEMA 1 style utilizes a door mounted indicator in lieu of a beacon.
12. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel
rating).
Note: NEMA 1 style utilizes an internally mounted buzzer in lieu of hom.
13. Exterior Alarm TesUNormal/Silence Switch allows hom and light to be tested
and hom to be silenced in an alarm condition. Alarm automatically resets once
alarm condition is cleared.
14. Horn Silence Relay (mounted on circuit board).
NOTE: other options available.
Entire control system (panel and switches) is UL Listed to meet and/or
exceed industry safety standards
AF Dual safety certification for the United States and Canada
AF Standard package includes three 20' SJE SignalMaster® control
switches
AF Complete with step-by-step installation instructions
Ar Five-year limited warranty
SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.
SEE PRICE BOOK FOR LIST PRICE.
Model Shown 1221 W114X6A
C®us
LISTED
Rh us.
PO Box 1708, Detroit Lakes, MN 56502
1-888-DIAL-SJE•1-218-847-1317
1-218-847-4617 Fax
email: customer service@sjerhombus.com
www.slerhombus.com
122 C
MODEL 12Tno
ALARM PACKAG
0 = select options or alarm package T T
= alarm package (includes tesdnornallsilence switch, fuse, red light, & ham)
ENCLOSURE RATING r
I = Indoor, NEMA 1 (metal)
= Weatherproof, NEMA 4X (engineered thermoplastic)
STARTING DEVICE
B1 = magnetic motor contactor 120/20a/240V
9 = magnetic motor contactor 120V only
PUMP FULL LOAD AMPS
0 = 0-7 FLA
1 = 7-15 FLA
2 = 15-20 FLA
3 = 20-30 FLA
PUMP DISCONNECTS
0 = no pump disconnect
4 = circuit breaker 120V (select STARTING DEVICE option 9 above)
120208240V (select STARTING DEVICE option 1 above)
2215
FLOAT SWITCH APPLICATION
H or L = pump down or pump up (select 17 option)
X = no floats
OPTIONS LiSfMbelow
6A
vv\��
ENCLOSURE UPSIZE - If you selected one or more of the * options, or two ** options,
a one-time enclosure upsize fee would apply.
cone ossmuvrnmt
IA Red beacon onhr I no audio
(must select 'O' for alarm package)
Q 1 C Horn only / no visual
(must select 17' for alarm package)
** 3A Alarm flasher
O * 30 Manual alarm reset
o * 4A Redundant off
(select Obtain 41) if (bats included)
Q 48 Red redundant oft indicator & alarm
(must salad Option 4A also)
Q 4D Redundant off float
(must select 4A option) (select 17 option)
(] * 5A Thermal wtou9heal sensor auto reset
(for pumps wMermal switch leads)
* 5E Sea[ failure coact & red indicator (2 wire)
(� 6A Auxiliary alarm contact, form C
(included as standard)
* 8A Elapsed time meter
(] * 8C Event (cycle) counter
Q * 9_A Pump overload
specify amperage after number 9 followed by leder'A'.
Example: 912A = 12 amp pump.
*� 0-25 FLA
* 25-30 FLA
10E Lockable latch -NEMA 4X
t0E Lockable Latch - NEMA 1
* 1 OF U"Ing arrestor (select pump drevd breaker)
k"�
COOS
DESCfePTgN
** 10K
Anti -condensation heater
11 C
NEMA 1 alarm panel
0
110
NEMA 4X alarm panel
F--J*
14B
Main disconnect (rotary style mounted through door, nori-ly H)
(must select Wcvil breaker)
*
0-20 FLA (total of both pumps)
*
20-60 FLA (total of both pumps)
16A
10' cord in lieu of 20' (per float)
16B
15' oord in lieu of 20' (per floa0
Q
16C
30' cord in lieu of 20' (per float)
Q
18D
4T cord in lieu of 20' (per float)
17A
SJE SignalMaster• I pipe damp 0 (per Hoar)
17B
SJE SignalMastei- I externally weighted • (per float)
Q
17C
Sensor Foal• l intemally weighted ♦ (per float)
Q
17D
Sensor Fooal' I externally weighted A (per float)
17E
Sensor Float` Mini / pipe camp ♦ (per Hoar)
0
17F
Sensor Float' Mini / externally weighted A (per goat)
0
17J
Sensor Floats l pipe damp ♦(per float)
0
19B
Lead lag selector switch
Q
19F
Fouts float to separate alarm hnclion from lag
19T
TOA (TestlOH/Aulomatic) switches and pump nun lights
through door mounted
19U
HOA (Hand/Of0Aulomatic) switches and pump run Lights
through door mounted
19X
Door mounted pump run indicator
Mechanicaayactrvated A Memuryactivated
JM/ArLG
MODEL 122� W 9 0 T
Alarm Package
Endosure Rating
Starting Device
Pump Full Load Amps
Pump Disconnect
Float Switch Application
Options: Auxiliary alarm contact, form C,
Elapsed time meter, event (cycle) counter,
SJE SigmiMastefO / pipe clamp
6A 8AC 17A
OSJE-Rhvhidu =14
0.
A,
0
p
3174}"
rr=-11 Fr
1111 V ��
4" CAS
o2A
LL r-JL
41"
t
40"
TOP VIEW
r 4" CAS
POLYLOK 12" ACCESS LID (TYP)
�Z SET RISER (TYP)
TANKS ARE MANUFACTURED TO MEET OR EXCEED ASTM C-1227 REQUIREMENTS
600 GPD GRAVITY DISCHARGE SYSTEM
H-600 A
H-600 A
TANK SPECIFICATIONS
DIMENSIONS:
WALL: 3"
BOTTOM: 3"
a
COVER: 4'
8
MANHOLE: 12' & 24' I.D. PLASTIC RISER
HEIGHT: 70" O.D.
S
'm
LENGTH 106" O.D.
g
WIDTH: 74 1/2" O.D.
BELOW INLET: 57° O.D.
`o
LIQUID LEVEL: 51°
WEIGHT: 11,135 LBS.
Lu x
W
INLET AND OUTLET:
!. §
4" CAST -A -SEAL (CAS) BOOT OR EQUAL
® N
COVER: MIX DESIGN #8 (NO FIBER)
't
CO
TANK: MIX DESIGN #9 (SMALL FIBER)
=z
CUSTOMIZED TANKS:
N
FOR CUSTOM TANKS CONTACT WIESER CONCRETE
r�
W� I
DO
W DO
0
a
z
g Q
U
$ a
DRAWINGS SUBMITTED = w
FOR APPROVAL
APPROVED BY: SHEET NO.
APPROVAL DATE: g
PRODUCTS NEEDED BY:
Hoot Service and Inspection Form
This testing and reporting shall be completed, signed and dated after each inspection. One
copy shall be retained by the maintenance company. The second copy is sent to the local
permitting authority and the third copy is sent to the system owner along with an invoice for
services by the maintenance company.
1. Actual Date of Visit:
2. System Inspection of Owner:
Address:
City, St., Zip:
Inspected Items:
Operational Inoperative Not Applicable
Aerator. .............. ...... ............
Aeration Plumbing .................
C
0
0
Air Filter .................................
0
Effluent Pump (if applicable)
Chlorinator .............................
o
0
OK System Light ....................
0
Alarm., ...................................
o
0
D-Box ..............................
o
0
Air Filter must be cleaned each service visit. Operation of effluent disposal system must be made
each visit (if pumped). A system with greater than 70% Settleable Solids in the aeration chamber
must be pumped to avoid solids leaving the tank for the drainfield.
3. Repairs to system (list all components replaced):
4. Tests Required and Results:
Test
BOD (Grab)
TSS (Grab)
Fecal Coliform
5.Comments
Required Results Test Method
I1
1
Signature of Inspector: Installer 11 or WW Lic #
Private Onsite Wastewater Treatment System Mound
Management Plan
Pursuant to SPS 383.54 Wis. Adm. Code each Private Onsite Wastewater Treatment
System (POWTS) Shall Include information and procedures for maintaining the system
within the parameters of SPS 383 and 384, and the conditions of approval by the
department, agent, or governmental unit. The approved plans and permits for the system
will be filed with the county zoning or health department.
This management plan complics with SPS 383.54, Wis Adm. Code, the Mound
Component Manual for Private Onsite Wastewater Treatment Systems (Version 2.0)
SBD-10691-P (N.01/01) R. 10/12 and the Pressure Distribution Component Manual
(Version 2.0) SBD-10706-P (N 01-01) R. 10/12
Table 1: System Design Specifications
Sanitary Permit Number
Number of Bedrooms
12
Design Flow GPD
1800
Soil Absorption Component Size . ft.
1000 (Pretreated Effluent
Trash Tank Capacity Gal.
400
Pump Chamber Capacity Gal.
1250 gallons
Type of Wastewater
I Pretreated Domestic
Pre -Treatment Unit installed per structure
HOOT SYSTEMS H 600 A
Table 2: Soil Absorption Component — Limits of Reliable Operation
Septic Tank Component
Soil Absorption Component
Design Flow -Peak GPD)
600 per structure
1800
Max. Influent Particle size
NA
<_ 1A Inch
Maximum BOD 5 (mg/1)
NA
<_ 30 mg/1
Maximum TSS (mg/1)
NA
s 30mg/ 1
Maximum FOG
NA
NA
Table 3: Maintenance Schedule
Septic Tank
Inspect and/or service once every 3 years
Dose Tank In- Line Filter
Should inspect once a year and clean every 3 years
Pump Chamber
Inspect once every 3 years
Soil Abso lion Com t
Flush laterals every 18 months.
HCOT SYSTEMS H-6W A
Service every 6 months for first 2 years. Then annually
there after per maintenance agreement. See attached.
Page 9 of 9 a, b + c
Septic Tank
The septic tank shall be maintained by an individual certified to service septic tanks under sec.
281.48, Stats. The contents of the septic tank shall be disposed of in accordance with NR 113,
W is. Adm. Code (Servicing Septic or Holding Tanks, Pumping Chambers, Grease Interceptors,
Seepage Beds, Seepage Pits, Seepage Trenches, Privies, or Portable Restrooms).
The operating condition of the septic tank and outlet fiber shall be assessed at least once every 3
years by inspection. The outlet filter shall be cleaned as necessary to ensure proper operation.
The filter cartridge should not be removed unless provisions are made to retain solids in the tank
that may slough off the filter when removed from its enclosure. If the filter is equipped with an
alarm, the filter shall be serviced if the alarm is activated continuously. Intermittent filter alarms
may indicate surge flows or an impending continuous alarm. The septic tank shall have its
contents removed when the volume of scum and sludge in the tank exceeds 1/3 the liquid volume
of the tank. If the contents of the tank are not removed at the time of an assessment, maintenance
personnel shall advise the owner of when the next service needs to be performed to maintain less
than maximum scum and sludge accumulation in the tank.
Ptunp Chamber
The pump chamber also requires monitoring once every three years or the time of problem,
complaint or failure. Inspection should include checking the dose rate, volume and frequency.
Warning: The dose chamber may fill due to flow continuing during pump malfunction or power
outages. One large dose when the power comes on or when the pump is repaired may cause the
dispersal system to have problems. In this situation, the pump chamber should be pumped by a
licensed pumper before pump cycling begins or other measures shall be used to dose the
component with only the proper amount of influent. This may include manual operation of the
pump controls until such time the pump chamber has reached its normal level.
Note: A Simtech STF-100 effluent filter will be installed in the dose tank for each
force main to provide the filtering of the effluent to the dispersal cell.
Septic tank and Pump chamber risers, access risers and covers should be inspected for water
tightness and soundness. Access openings used for service and assessment shall be sealed
watertight upon the completion of service. Any opening deemed unsound, defective, or subject to
failure must be replaced. Exposed access openings greater than 8-inches in diameter shall be
secured by an effective locking device to prevent accidental or unauthorized entry to the tank
Warning: No one should enter a septic or other treatment or holding tank for any reason without
being in full compliance with OSHA standards for entering a confined space. The atmosphere
within the septic or other treatment or holding tank may contain lethal gases, and rescue of a
person from the interior of the tank may be difficult or impossible.
Tank abandonment shall be accordance with SPS 383.33, Wis Adm. Code when the tank is no
longer used as a POWTS component -
Page 9 of 9 a, b + c
Soil Absorption Component
The soil absorption component serving this structure is designed to accept domestic wastewater
from a residential facility. The limits of operation of this component are shown in Table 2.
The longevity of a soil absorption component depends greatly on proper and timely maintenance,
and system use within or below the limits of reliable operation. Good water conservation
practices by all occupants and the installation of water conserving plumbing fixtures are key
factors in extending the useful life of this component.
The soil absorption component's operation must he assessed by inspection at least once every 3
years. Lateral turn ups are provided at the ends of the laterals for the purpose of flushing the lines
of any solids. Flushing these lines should be done every 18 months. The inspection shall include
recording levels of ponding, if any, in the observation pipes, and visual inspection for any
evidence of surface discharge from the component. On steeply sloping sites, areas of erosion
should be identified and reported to the owner for repair. The surface discharge of domestic
wastewater or sewage from the system is prohibited and considered a human health hazard.
Traffic around or over the soil absorption component should be avoided particularly during
winter months. The compaction or removal of snow cover over the component may lead to
hydraulic failure by freezing. This type of failure is usually temporary, but is difficult or
impossible to repair until weather conditions improve. In general, soil compaction over this
component will reduce diffusion of oxygen into the soil and dispersal cell, which may lead to
more intense, and earlier, clogging of the soil.
Planting of deep rooted trees and shrubs directly over or within 10 feet of the component should
he avoided since root intrusion into the component may obstruct wastewater flow.
Continaency Plan
In the case of septic or dose tank component damage, measures shall be taken to repair or replace
the tanks to there original operating condition. Problems with the pretreatment unit should be
addressed to the POWTS Maintainer. Bi-annual/ annual inspections should prevent any complete
failure. Should failure of the distribution cell component happen, the system shall be inspected to
determine the cause of failure, effluent quality testing and wastewater flows. Steps taken to repair
or replace the dispersal cell may involve the removal of a bio-mat which would require cleaning
or replacement of the distribution network as well as replacing the aggregate system and clogged
portions of the sand fill.
Component Owners Contact List
Keith Knudtson
Plumber/ATU Maintainer
(651) 470-1737
St. Croix County Zoning
(715) 386-4680
Wieser Concrete Products
Maiden Rock WI
(800) 336-3416
Septic Pumper
Powers Sanitation
(715) 249-5738
HOOT SYSTEMS LLC
H-600 A
888) 878-4668
Page 9 of9ab+c
f
�inoonn/n
Department of Comrrlenm
Division of SAO and Buildings
P A
SOIL EVALUATION REPORT #1862
in accordance with Comm 85. WG, Adm. Code Page 1 of 3 _
Steels Sol Service
Attach complete site plan on paper not less than 8'% x 11 inches in sote. Plan must
County St Cl
include, but not limited to: vertical and horizontal reference point (BM), direction and
percent slope, scale or dimensions, north arrow, and location and distance to nearest road.
Parcel I.D_
Please print all informad
-
Personal information You pwioe may be used br ( vary Lan, s. 1504 (1) (m)).
R
O
Property Owner
RIro
Property Location
Rolling Hills Of Hammond C.
Govt Lot na NWt/4, SW1M, S29, T29N, R17W
Property Owners Mailing Add
So-
Lot 4
BlOclli
Subd. Name or CSAits
400 2ntl
no
1 Rollin Hills Farm ^
city ZP GR
❑ City ❑ Vdlage Z Twm Noorep Road
gg
Hudson WI 54016 386-0230
Hammond 160Th St
M New Construction Use: idential / Number of bedrooms 4 Code derived design flow rate 6W GPD
Replacement ❑ Public or commercial - Descntle_ na
Parent material Silty sediment and underlying reddish sandy loam fill Flood plain elevation, N applicable no ft.
General comments Mound design, system elevation 100.4811 based on confolw ire elevation 99.401L hiiwman 13 inches of
and recommendations: ASTM C-33 Mound sand.
E.
g
N Pit Ground surface elev. 100.10 ft. Depth to lanlvg factor 62 in. Soil Appecalon Rate
Horizon
Depth
lo.
Dominant Color
Munsel
Redox Description
Qu. Sz. Cont. Color
j Texture
Structure
Gr. Sz. Sh.
Consistam
Boundary
Roots
GPD_A_ l'
-EI1n
-Eea2
1
0-21
10vr3/2
clone
I
2msbk
mfr
CS
21'
.6
.8
2
21r40
1""/4
cache
old
2msbk
mfr
gw
1vf
A
.6
3
40-50
10yr4/4
none
Is
2msbk
mvfr
gw
1vf
.7
1.6
4
SG-62
10yr5/8
rgne
Is
OS9
I mfr
Cs
no
.7
1.6
5
62-80
10vr5/8
c2d 7.5yr5/6
sill
am
ml
cs
no
.0
.2
6
BD-90
710 gley+c2�d-IyrS/67.
sc
om
mfr
no
no
.0
.0
Boring a ❑ Bormg -
® pit Ground surface elev. 100.10 _ ft. Depth to Inning factor 37 In. Soil Appiuial Rile
Horizon
Depth
in.
Dominant Color
Munsd
Redox Description
Qu. Sz Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consislism
Boundary
Raab
GPD/R
'Eftat
'01112
1
0-12
10yr3/2
clone
sil
2msbk mfr
Cs
if
.6
.8
-25
10yr l/4
none
Sid
2msbk
mfr
CS
lvf
.4
.6-37
5WV4
none
sl
om
no
gw
no
.2
.6
4-3V74-84
1005/8
CM 7.5yr5/6
ski
om
fro
no
re
.0
.0
I
cmiuem e1 = r ? ,1u < z2o mg/L and TSS >30 < 1 W mg/L ' Effluent a2 = BODs < 30 m & and TSS < 30 mg/L
CST Name (Please Prim) Signature' - CST Number
David J. Steel 248956
Address Steers Soil Service Date Evaluation Conducted Telephwne Number
994 200th St. Bakhvin, WI 54002 5/5/2006 715-760-0347
mnow(Kwm)
Property Owner Rolhng Hills Of Hammond LLC Parcel ID i Pending_.
Page 2 of 3
Boring 9
❑Boring _
® Ps Ground surface elev. 97.60.— R Depth to Imtitirg factor 23 _ in. Sd MI*gin Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Ou. Sz. Cont- Color
Texture
Stmdure
Gr. Sz- Sh.
Consistence
Boundary
Rods
GPDW
'ER1
'EI/2
1
0-10
10yr3/1
none
skit
2mSbk
mfr
CS
lvf
.6
.8
2
10-18
10yr4/4
rode
Sid
sd
2nlsblt
mfr
CS
na
.4
.6
3
18-23
SOyr4/4
—none —
2msbk
rnfr
gw
na
.4
.6
4
23-55
10yr5/8
map 7.5yr5/6
sit
Om
na
na
na
0
.2
ng
Boring s Bo"
Pit Grouts surface elev. R Depth to Innitirg tailor ki. Application Rals
Horizon
Depth
in.
Daninanl Color
Munsell
Redoz Description
Qu. Sz. Copt Color
Texture
Structure
Gr. Sz Sh.
nsisterrce
Boundary
Rods
GPDIIR
-EM
I
i
Boring 0 Boring
J Pit Ground surface elev. ft. Depth to limiting factor in- Sill Application Rate
Horizon Depth
in.
Dominant Color
Munsell
Redox Description
Qu. Sz. Gont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPDIR'
'Efls1
'Etf{2
Effluent s1 = BOD? 30 - 220 mg/L and TSS >30 < 150 mg/L ' Effluent a2 = BODS <_90 nV& and TSS 1-90 MgA-
T'he Deparunent of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
need mistaial in an alternate formal, please contact the deparunent at 608-266-3151 or M 606-264-8777.
sa6r3" ( vM) skids Sol sadx
r
STEEL'S SOIL SERVICE
David J. Steel Rolling Hills Of Hammond LLC 994 20e St.
CST-POWTSM NWl/4,SWl/4,S29,128N,R17W Baldwin, W154002
Lic. #248956 Town of Hammond, St Croix Co. Direct 715-760-0347
Rolling Hills Farm Lot 45 Fax 715-684-3449
This soil evaluation was conducted to satisfy a zoning requirement, it may or may not be suitable for your use.
The location of this test may or may not be as shown, as permanent lot Imes were not established at the
time the soil test was conducted.
Legend
P = 40'
♦ = Benchmark Ele. 100.00 ft
Top of 3/4" pvc pipe
• = Alt Benchmark Ele. 99.65 ft
Top of 3/4" pvc pipe
❑ = Borings
Boring Elevations
Bl = 100.10 ft
B2= 100.10 ft
B3 = 97.60 It
B4 = 0.00 ft
N
3of3
v
%p/win SOIL EVALUATION REPORT #1861
Deparbnenl of Commerce in accordance with Comm 85, Wis. Ad, Code Page 1 of 3
Division of Safety and Buildings Skits sod
County
AttachcompleteSib plan on paper not less than 8'r4 x 11 inches in size. Plan must St. Crobt
include, but not limited to: vertical and horizontal reference point (BM), direction and —
percent slope, scale or dimensions, north arrow, and location and distance to nearest road. Parcel I.D.
Please print all r R
-/• (/
PeraarW irdormaion YOU Pohde may be used for _ (Privacy taw, s_ 15.04(1) (m)).
Rolling Hills Of Hammt n _ CA - �QQ_6Gwt. Lai na NWim. swim, S29, T20K R17W
Property Owners Mrirrg Add s '0 - Lo1 i Blodt • subd. Nama or GSIa"
400 2rd st V�- N� 46 no Rolling Hills Farm
City Coda.p\ r L] Csyy vaaga ® Town Neared RoadC.ode.p\� r L] city ❑ Ysaps ® Town Nsarad Road
Hudson 5��6 5-388-0230 Hammond 160Th St
New Construction Dse: ® I I Number of bedrooms 4 Coda derived design flow tale 600 GPD
Replacement ❑ Pubic or commercial - Describe: na
Parent material Sft sedkrtard and�reddishbam iFlood plain elevation, if appicable .. n9 ft.
General comments Mound design, system elevation 101.05ft based on contour line elevation 99.45ft. Minimum 19 inches of
and recommendelipw: ASTM C-33 Mound sand.
❑
Borrge El Bill l
® PH Ground surface elev. 100.55 ft. Depth to limiting factor 17 in. Soil Application Raft
Horl
Depth
in.
DormantColor ReclM Descriptom
Murlself Qu. Sz Cont. Color
Taidlee
Structure
Gr. Sz. Sh.
Corawaterioil
Boundary
Roots
C44W
'an
•E�a
1
0-8
10yr3/2
none
I
2nisbk
I mfr
a
if
.6
.8
2
3
8-17
5yt4/4
Role
Sid
2MSbk
rr*
a
is
lvf
.4
.6
17-36
10111r5/8
t2d 7.5yr5/6
Sid
an
na
na
•0
.0
4
36-120
Will
none.
Is
asp
col
rla
na
.7
1.6
2]
Boring e ❑ Boring
® Pd Ground surface elev. 1W.55 it Depth to limiting factor 17 in. Soy Application Ri is
Horton
Depth
n.
Dominant Color Reddy Description
Munsell Qu. Sz. Cont. Cola
TeMure
Stnrcrure
Gr. Sz. Sh.
Cores
I
Boundary
Roob
GPD)R
'Flit
'EM
1
0-6
10yr3/2
none
I
2msbk
111f1'
Ill
is
is
if
na
.6
A
.8
.6
2
8-17
SW4/4
noire
sd
2msbk
3
17-36
101115/8
f2d 7.5yr5/6
Sr
am
na
is
its
.0
.2
4
WIN
10111/6
� flf 7.5yr5/6
is
clap
rm*
no
to
.7
1.6
- trmbrr e1 = BOD 5> 30 < 220 m9ti _ • Eftiralt e2 = BODs < 30 mgA- and 1 SS < 3tr mWL
CST Name (Please Print) " "Signature' CST Number
David J. Steel _ 248956
Address Steers Sal Service Data Evaluation Concluded Telephone Number
994 2001h St. Baldwin, WI 54002 5/5/2006 715-760-0347
Property Owner Rolling Hills Of Hammond LLC. Parcel ID a _ Pending _ Page 2 of 3
Boring
Win
® p p Ground surface elev. _ _ 97.55 _ R. Depth to limiting factor _ 18_ in. Sail Application Rate
Horizon
Depth
in.
Dormant Color
Munsell
Redox Description
Qu. Sz. Cont. Color
Texture
Structure
Gr. Sz Sh.
Consistence
Boundary
Roofs
GPDAP
-Eaa1
'EIM
1
0-8
10yr3/2
none
I
2msbk
mfr
cs
if
.6
.8
2
618
10yr4/4
none
sd
2msbk
mfr
gw
na
.q
.6
3
18 56
10yr5/8
f2d 7.Syr5/6
is
ON
mvfr
fs
no
.7
L6
q
56 80
10yr6/6
t2d 7.Syr5/6
Is
am
ar&
na
rta
.7
1.6
i
Ibliaon M has 7.Syr5/6 smtlhg in IL
Boring a L Ong
Pk Ground surface elev. ft Depth to gniting factor in. 't AW*MMon Rals
Horizon Depth
in.
Dominant Color Redox ()ascription
Munsell Qu. Sz. Cont. Color i
Texture
Structure
Gr. Sz Sh.
Consistence
Boundary
Rods
GPDff
❑ Bong / __j Boring
--, pitGround surface elay. fL Depth fe IYaftlr 9 factor in. Sail Application Rose
Horizon
Depth
in.
Dominant Color . Redox Description
Munsell Qu. Sz. Cont. Color
Texkxe
Shudure
Gr. Sz Sh.
0onsislioncet
Boundary
Roots
GPDM
TIM
-EW2
Effluent at = B0135> 30 < 220 ng& and TSS >30 < 150 m & ' Effluent art - BOOS < 30 mglL and TSS -c30 rtg&
The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
need material in an alternate fortnat, please contact the department al 608-266.3151 or TTY 608-264-8777.
sa"]"(R.07M) SRd's so Seim
4
STEEL'S SOIL SERVICE
David J. Steel Rolling Hills Of Hammond LLC 994 20e St
CST-POWTSM NWl/4,SWl/4,S29,T28NR17W Baldwin, W154002
Lic. #248956 Town of Hammond, St Croix Co. Direct 715-760-0347
Rolling Hills Farm Lot 46 Fax 715-684-3449
This soil evaluation was conducted to satisfy a zoning requirement, it may or may not be suitable for your use.
The location of this test may or may not be as shown, as permanent lot lines were not established at the
time the soil test was conducted
/
Legend
1" = 40'
♦ = Benchmark Ele. 100.00 It
Top of 3/4" pvc pipe
• = Alt Benchmark Ele. 99.75 It
Top of 3/4" pvc pipe
❑ = Borings
Boring Elevations
Bl = 100.55 ft
B2 = 100.55 ft
B3 = 97.55 ft
84 = 0.00 ft
3of3
I
eyaeH••a• S
/
it § a l,
_ ng
qA
qQ
9�
%
g 9>v
•4:4 . � '
g .
�y.r
�k
wig
a
,
— ,__ .....,�...... � •-■fit--,uTNRi3-;m`z-----
1 •--- I � I i� I I
re
v Visconan
Department of Commerce
Division of Safety and Buildings
SOIL EVALUATION REPORT PJL"#188t
in accordance with Comm 85, Wis. Adm. Code Page 1 of 3
Steers Soil Service
Attach complete site Ian on paper not less than 8% x 11 inches in size. Plan must
P P P Pe
County
St. Croix
include, but not limited to: vertical and horizontal reference point (BM), direction and
slope, scale or dimensions, north arrow, and location and distance to nearest road.
Parcel I.D. _�-
percent
.100
Please print all inform
Re id Dat
purpo Personal information you provide may be used for se (Privacy Law, s. 15.04 (1) (m)).
�
Mb�
Property Owner `
Property Location
Rolling Hills Of Hammon
Govt. Lot na NW1/4, SW1/4, S29, T29N, R17W
Property Owner's Mailing Add ss A,
lot*
Block #
Subd. Name or CSM#
400 2nd at \S�- �N�
46
na
Rolling Hills Farm
city to Zip C�(or�O\ one r
❑ City ❑ Village E Town Nearest Road
Hudson 5A.6 5 386-0230
Hammond I 160Th St
New Construction Use: ential / Number of bedrooms 4 Code derived design flow rate 600 GPD
r- Replacement i Public or commercial -Describe: na
Parent material Silty sediment and underlying reddish sandy loam till Flood plain elevation, if applicable na ft.
General comments Mound design, system elevation 101.05ft based on contour line elevation 99.45ft. Minimum 19 inches of
and recommendations: ASTM C-33 Mound sand.
❑
Boring #� Boring
Pit Ground surface elev. 100.55 ft. Depth to limiting factor 17 in. Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Cu. Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/ff
-Enst
-Eff#2
1
0-8
10yr3/2
none
I
2msbk
mfr
cs
if
.6
.8
2
8-17
5yr4/4
none
sid
2msbk
mfr
cs
1vf
.4
.6
3
17-36
10yr5/8
c2d 7.5yr5/6
ski
om
na
CS
na
.0
.0
4
-26-120
10yr6/6
none
Is
osg
ml
na
na
.7
1.6
21
Boring # C Boring
FC Pit Ground surface elev. 100.55 ft. Depth to limiting factor 17 in. Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Qu. Sz. Cont. Color
Texture Structure ConsistenceBoundary
Gr. Sz. Sh.
Roots
GPD/fe
•Ee#f
-Effs2
1
0-8
10yr3/2
none
I
2msbk
mfr
cs
ifF.6
.82
8-17
5yr4/4
none
sd
2msbk
mfr
cs
na
.63
17-36
10yr5/8
f2d 7.5yr5/6
sit
om
na
Is
na
.2
4
36-120
10yr6/6
flf 7.5yr5/6
Is
osg
mvfr
na
na
1.6
_ L - t_ wenr sz = uuu51 ou mgrc ana i as a.av ngrL
CST Name (Please Prim) �"" ""Signature: CST Number
David J. Steel Cc- 248956
Address Steel's Soil Service Date Evaluation Conducted Telephone Number
994 200th St. Baldwin, WI 54002 5/5/2006 715-760-0347
SRD 030 (a 47M)
Property Owner Rolling Hills Of Hammond LLC. Parcel ID # Pending Page 2 of 3
Boring # ❑ Boring
❑'. pit Ground surface elev. 97.55 ft. Depth to limiting factor 18 in. Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description Texture
Cu. Sz. Cont. Color
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPDM
•Eff#1
*Eff#2
1
0-8
10yr3/2
none
I
2msbk
mfr
a
if
.6
.8
2
8-18
10yr4/4
none
scl
2msbk
mfr
gw
na
.4
.6
3
18-56
10yr5/8
f2d 7.5yr5/6
Is
osg
rn*
CS
na
.7
1.6
4
56 80
10yr6/6
c2d 7.5yr5/6
Is
osg
mvfr
na
na
7
1.6
Horizon #4 has 7.5yr515 staining in it.
❑ Boring# ❑ Boring
❑ Pit Ground surface elev. ft. Depth to limiting factor in. Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Cu. Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/fp
'Elf#1
'Elf#2
❑ Boring # ❑ Boring
pit Ground surface elev. ft. Depth to limiting factor in. Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Qu. Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPDflP
•E1f#1
'E1182
Effluent #1 = BOD? 30 < 220 mg/L and TSS >30 < 150 mg/L ' Effluent #2 = BODs -S 30 mg/L and TSS -30 mg/L
The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
need material in an alternate format, please contact the department at 608-266-3151 or TTY 608-264-8777.
s111>4330(rt01i00) sexes soa smite
3of3
STEEL'S SOIL SERVICE
David J. Steel Rolling Hills Of Hammond LLC 994 200' St.
CST-POWTSM NWl/4,SWl/4,S29,T28N,R17W Baldwin, W154002
Lic. #248956 Town of Hammond, St Croix Co. Direct 715-760-0347
Rolling Hills Farm Lot 46 Fax 715-684-3449
This soil evaluation was conducted to satisfy a zoning requirement, it may or may not be suitable for your use.
The location of this test may or may not be as shown, as permanent lot lines were not established at the
time the soil test was conducted.
Legend
1" = 40'
♦ = Benchmark Ele. 100.00 ft
Top of 3/4" pvc pipe
• = Alt Benchmark Ele. 99.75 ft
Top of 3/4" pvc pipe
❑ = Borings
Boring Elevations
Bl = 100.55 ft
B2 = 100.55 ft
B3 = 97.55 ft
B4 = 0.00 ft