032-2132-10-100
Wisconsin Department of Commerce PRIVATE SEWAGE SYSTEM County: St. Croix Safety and Building Division , • INSPECTION REPORT Sanitary Permit No: 408292 0 GENERAL INFORMATION (ATTACH TO PERMIT) State Plan ID No: Personal information you provide may be used for secondary purposes [Privacy Law, s.15.04 (1)(m)]. Permit Holder's Name: City Village X Township Parcel Tax No: Peterson, Robert I Somerset Township 032- 2132 -10 -100 CST BM Elev: Insp. BM Elev: Description: DD -o /od , I BM ?Vc ,tea- T 3 TANK INFORMATION ELEVATIO ATA TYPE MANUFACTURER CAPACITY STATION BS HI FS ELEV. Septic 1 � Benchmark -II Dosing Alt. BM ST Aeration Bldg. Sewer Holding St/Ht Inlet 133 TANK SETBACK INFORMATION St/Ht Outlet t N TANK TO P/L WELL BLDG. Vent to Air Intake ROAD Dt Inlet Septic I D047 / 2 -3 3 D Dt Bottom ! �� osing / Header /Man. (j . /O Aeration Dist. Pipe Z y q°/• ��- Holding Bot. System / Z '1 ' A ' ^ + Final Grade PUMP /SIPHON INFORMATION C .v /0/ , S Manufacturer Demand St Cover GPM Model Number r I f S 3 /5, TDH Lift Friction Loss rV System TD Ft r .) �.v Jr N A j1 l Forcemain Length I Dia. DistAo / Well Z SOIL ABSORPTION SYSTEM I --� ; B ENSI NCH Width 5 Length No. Of Trenches PITT DIMENSIONS No. Of Pits Inside Dia. Liquid Depth DIMENSIONS SETBACK SYSTEM TO P/L BLDG IWELL LAKE /STREAM LEACHING Ma�fact INFORMATION T e Of System: y CHAMBER f W I' L"T ay S-�nn / � ZJ / WA Model Number: DISTRIBUTION SYSTEM J Header /Ma Distribution x Hole Size x Hole Spacing Ven Air Intake Length Dia Length Dia acing SOIL COVER x Pressure Systems Only xx Mound Or At - Grade Systems Only j Depth Over Depth Over xx Depth of xx Seeded /Sodded Edges soil xx Mulched Bedfrrench Center Bed/Trench Edg Top ❑ Yes No Yes [ No COMMENTS: (Include code discrepencies, persons present, etc.) Inspection #1:/_/w/ Inspection #2: / ! Location: 858 174th Ave Somerset, WI 54025 (NW 114 SE 1/4 f1 TT30N R19W) Rocky Ridge Estates Lot 2 Parcel No: 01.3 1.) Alt BM Description = �/ �0Z 0 A4d 1t.�" Aa,-K r I C GJ�`frb — /'t,uo /`' - 2.) Bldg sewer length = 23 / ry l gt" �¢ ,Q,ffin 4" aw�B ayp� ) C , - amount of cover = to I/ _ Plan revision Required? Yes No to ZL( D Use other side for additional information. J — - - - - -__ ----- - - - - -— L -- - - -- -- -_ _ J SBD -6710 (R.3/97) Date Insepctor's Signature Cert. No. — -- sigij aad C 7 sin 201 W. w agon Ate-. P . O. Box n62 Madison. wI 53707 Via 7162 / y O/ S Oe anment of Commerce S sao Nutea Sanitary Permit Application in accord wLh Carom 2331. Wis. Adm. Cade. personal WO M FMMO O Cbeac f Bavidon be used fur t Sme Plan LD. Number L � - rAm PrW AN Iafar wdm iaroa Nun*= # 0. 1q, i JID A PiapettycwntesName JUL 3 0 2002 0'32- ;, O'x CU Of La ce°on pnopeny 0wmes Maft Adder n. OF Jr — � — ;t• Sl/ N. yip Code Phone Number Lot a Block Numb" City. State p� Subdivision Nadw CSM Num ber t ' 0 - sqo) at BSS (deem an dad apply) > OVRIMM or 2 Fam2Y Dwdit — Number of Bedroama O PobtidCaaamteteial— Describe Use - S Neat Road ❑ Stow oarned IQ. Type of Peradt: (Ci* � me boat on Not A (m�baft afire for haun l use). Complete iae B if ) R *am 3 o RWkcement of 6 (1 Addition. to Fa c use A- ZO Tank Dme Iswed B. ❑ Check if S� permit pte+►rou* � Permit Number IV. of l ( � atbmae is for internal 44 ia- cnewad 21❑ Mound 48 ❑ Saud Floor 50 ❑ Commucoed Wedand ❑ pt ed k4konnd 41 ❑ Took 4s ❑ paw 51 Drip UM 4s ❑ At�ade 46 ❑ Aerobic T eat Usk 11 - 30 o V. De Am Anew gM Apphpdioa � Percolation Rate Elevation Desipn `S4d' proposed 1 ,03 , s Prefab Sir s1 P lastic VVL Tank Info Capdmy m . Total Number RI&CIU �/ d CRaas Qanoas Cialloas ltca► Bxkft 1 0C 4 t. � 3a� Septic of l3ol" TW* 7C nosias Cbeniber (o OII. 8tatemteat ass�te far haaWl tioa of the pown dawn on the attadwed OWN - A�/11D'RS Number Business Pfroae Num / her Plus Name 0`404 Z Z plumbs s Address (Str & City. SI'm 2'Z vae ss Permit eiocmdes tiro®dwaar Date ifaatal Agent Stautps) AWwvW O Dl:approved Soxclarge Fee) _ e O owns � lrwd A&«sc canaltdnos of Ap t►Reasoas for Disapproval dKCaS X4-1 Ss �" Who As doe ,,, °'o� '., pow a d k em =a a CRTI 'A()R (R 0S /01) I PLOT PLAN PROJECT Robert Peterson' ADDRESS 1745 85th St. New Richmond Wi 54017 NW 1/4 SE 1 /4S 1 /T 30 /R 19 TOWN Somerset COUNTY ST. CROIX MPRS Shaun Bird 226900 DATE 7/26/02 4 BEDROOM CONVENTIONAL M IN -GR`O PRESSURE CONVENTIONAL LIFT HOLDING TANK MOUND SEPTIC TANK SIZE 1260 LIFT TANK SIZE DOSE TANK SIZE HOLDING TANK SIZE LOAD RATE •4 ABSORPTION AREA 1586 # of chambe 51 k BENCHMARK V.R.P. Top of V Pipe ASSUME ELEVATION 100' Filter Zabel A -100 ❑ BOR6 WELL Same as Benchmark NATION . S� D j SYSTEM ELEVATION $��y / d Z Vent >6„ Standard Infiltrator Plans Designed Using �e� Leaching Chamber Conventional Powts 7 a of Cover 12" with 31.1 ft2 of Area Manual Version 2.0 6' Long G � Grade at System Elevation a� 34" U h,• o B -1 10' r, 50' Vents 3 -3' X 107' Cells with >3' Spacing 5' B -3 21' 12% Slope 1 ' B -2 f ,� r /VA. 611 ! M?- B -5 3 20% Pro 4 130' Slope Bedroom House 1 . B -4 r 10' Vents 84" / A t Q J�0!✓ 250' B. . Alt. B.M. 174th Ave II PLOT PLAN PROJECT Robert Peterson' ADDRESS 1745 85th St. New Richmond Wi 54017 NW 1/4 SE 1/4S 1 /T 30 /R 19 TOWN Somerset COUNTY ST. CROIX MPRS Shaun Bird 226900 DATE 7/26/02 BEDROOM 4 CONVENTIONAL XXX IN -GRO PRESSURE CONVENTIONAL LIFT HOLDING TANK MOUND SEPTIC TANK SIZE 1260 LIFT TANK SIZE DOSE TANK SIZE HOLDING TANK SIZE LOAD RATE .4 ABSORPTION AREA 1586 # of chambers 51 BENCHMARK V.R.P. Top of 1" Pipe ASSUME ELEVATION 100' Filter Zabel A -100 ❑ BOR HO WELL Same as Benchmark SYSTEM ELEVATION , ®7 Vent � � s: � la >6„ Standard Infiltrator Plans Designed Using of Co Leaching Chamber Conventional Powts -3 Cover with 31.1 ft2 of Area Manual Version 2.0 ' 12" �'✓ 6' Long 34" Grade at System Elevation a� Uw o �, B -1 10' 50' Vents 3 -3' X 107' Cells with >3' Spacing 5' B -3 21' 12% Slope 1 ' B -2 B -5 3 20% Pro 4 130' Slope Bedroom House 1 T B -4 10' Vents 84 , r l,DC7 �wL d'r � ��✓ \ y.c,, n � ` � -t. 250' B. Alt. B.M. IF 174th Ave Wisconsin Department of Commerce SOI D SITE EVALUATION f ` Division of Safety and Buildings Page of Bdreau of Integrated Services in or&h6e `with s `AHR 83.09, Wis. Adm. Code Attach not less than Ian site complete on paper t2 x 11 inc l County p p p p �dirt Ian mus t`�� f include, but not limited to. vertical and horizontal refe.s2nce poihtdAe); �tion and Croi� percent slope, scale or dimensions, north arrow, #rtitl location and distance to nearest road. Parcel I.D. # i. 032- 2 Oa 6- /D APPLICANT INFORMATION - Please i all in Ftll4n. l Reviewed by Date UN7 Personal information you provide may be used for second l pafpostt�5 15.04'O j (tyi)). �� C� Sg Pro erty Owneer P' erty Location SJ 0 0, Pe APIfC� /7 ovt. Lot 60 1/4 S 1 /4,S / T _7C) ,N,R ! / for) W Property Owner's Mailing Address Lo # Block# Su d. Name or CSM# 17S`' l AS � Cit � / Nearest Road A l State Zip Code Phone Number ive 1? t / 01O'� UUI S 617 ( .76 - ) 2Vb,fY75„ El city El villa © Town fsr Ul ® New Construction Use: Residential / Number of bedrooms Addition to existing building ❑ Replacement ❑ Public or commercial - Describe: Code derived daily flow 600 gpd Recommended design loading rate ' 7 bed, gpd /ft • trench, gpd /ft Absorption area required Soo bed, ft ) 00 trench, ft Maximum design loading rate o • s g g bed, gpd /fi trench, gpolft Recommended infiltration surface elevation(s) 9q • ft (as referred to site plan benchmark) Additional design /site considerations Parent material G/1 c im / T l I & 27 a ir De Q M err" ZO , Flood plain elevation, if applicable 1 114 ft S = Suitable for system Conventional Mound In- Ground Pressure AT -Grade System in Fill Holding Tank U = Unsuitable for system [J s El U ® S El u ®s ❑ u ®s ❑ u ❑ S S U ❑ S 91 U SOIL DESCRIPTION REPORT Boris # Horizon Depth Dominant Color Mottles Structure GPD /ft Boring Texture Consistence Boundary Roots in. Munsell Ou. Sz. Cont. Color Gr. Sz. Sh. Bed Trench f I o-s oY ja msm r�v�� c w 2m • y .3' ?,27 /o S� msb m���� c w ! m s y .•S Ground 3 el v Depth to limiting facto >in. Remarks: JJ ,AI Boring # I - me Jr C w y s 2 -32 10 rR z / z Jr�sb yna�'i c w 1 m . q , . s' Ground elev. © ft. Depth to limiting fa t qr in. Remarks: CST ame (Please Print) Aignature Telephone No. frQ 7 a01e 71 5 - ZV7 - 320-? Address V �k �e Date CST Nu T 7 Y/ I y - z2 9f' 23 )3�' k. PROPERTY OWNER g (L S Jf // �` ' 9 e�( Ilso`SOIL DESCRIPTION REPORT page �Z of PARCEL I.D.# 0,? 2 .200 d- 1V Lo r Boring # Horizon Depth Dominant Color Mottles Texture Structure Consistence Boundary Roots 2 in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. Bed ,Trench ®YR/z Cw 21 c Ground Cog S r 5 z- /m u , 1 3 I " ft- Depth to limiting !7 ,j'L,, L" factQF/ Remarks: Boring # -� /aiR 3z S4 m1'bk cw 21n a v -T 6-18 1011 :z /Y ,4 1h vf, c w 3 mc- 1 t4 Ground I l . ft .� , ;v Depth to limiting f�t� in. Remarks: Horizon Depth Dominant Color Mottles Structure GPD /ft Texture Consistence Boundary Roots in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. Bed , Trench Boring # Mub- CIO 3 I -70 7, S�' /c� y /3 /v/� L li Jr►�� 1 , y . �" Ground � ft Depth to limiting ' c�or E n ' Remarks: Boring # Ground elev. ft. ' Depth to limiting factor in. Remarks: SBD -8330 (R. 07/96) ' i f i e�dff 404- C r/ /om, D! 'IC4 m C � fen st $ oLtNi lest G4V` f conhei X 03• Li LO i ' 1 t 4 ' 4 , I — . i i } , 7 i I " 1 , i , t a i 1 i i I i t i } .� --_._ (t � �. . M. — � � { � °T• ! / a - 1' - - _ , mot � � _1 J -- _.ti— _._.._.. _.. + - � —� _ —' , , i i ' d e' .. 3• _ '7•r ✓. a ✓ {. }{� •; �.,.• 4 r. ✓ + •. r., . • .,{r ✓ :. r, t ° dr!;�1HSip, XK ✓ i t' r: ✓ : �♦ • 4 �. y '.e • • ,. e ✓ • ' 4♦ SSA. Mp r .t ° ✓6 ;✓ ;: ,ter• .. :�,. PY dt ',; ! r Y ♦ ,1 � • ' ^R .� 'T iii A.7 1II1'''' • 1 {. f �:'. {' ✓i ,rL y ti: }. ✓ ✓. • 1 Y ✓ } f7 ✓ +t t Y:' : is ✓r ¢ ,r z Maintenance and Contingency Plan for a Septic System Maintenance Plan 1. Septic Tank is to be pumped once every 3 years. 2. Effluent filter is to be cleaned once a year. Please note: a larger filter is being installed in order to extend the maintenance interval of the filter. 3. Once every 3 years, cells are to be inspected via the inspections pipes at the ends of the cells. 4. Owner agrees to limit greases, garbage, and water conditioner discharge into the system. 5. The owner agrees to save this plan. 6. Do not plant trees nor park nor drive over system. 7. Watershed is to be diverted away from system. 8. Discharge into system is not exceed those required as per Comm. 83 Contingency Plan 1. If system fails, determine cause of failure, use alternate area and install new system or install system at a lower elevation. 2. Replace any other failing components as needed. Plumber: Shaun Bird 715 - 246 -4516 St. Croix County Zoning 715 - 386 -4680 Pumper Tom Mondor 715 - 246 -5148 Shaun Bird #226900 r FROM P C COL Lt3UP BL 1 NC ! NH N 715 549 5911 Jan. 03 2002 36: 013PM P2 ROM COUNTY SIa''rf AINTENANCE AGREEMENT AND I . CERTIFICATION FORM l Owner/Buyer so rt I Mailing Address S Property Addrts FS lication retlui Plait h Departracnt for new construction) City/3tata ,1�e-W 6 4 P Identification Number el 5 g j O , fp — L . 0 LF.C�;AL DESCM MN Property Location - V, ;L._ I. 7 D N -RA- Town of �os,Yr.s,c Snbdiviaion .c7 Lot # . z Certified Survey so # volume 7 , Page # 26 Wttmaq Deed # -- Volume Page it y 0 Spec houss O y" gj Lot lines identifiable M yes S+ E mwrow use jW o! , c ooetid result is itr pceaoaiure.fsilu0e to hamlle wastes. Proper rwtiAteaaace eon at pmon 4 svfw unk sooner, if needed by a lieeesod pumper. Whit you plat into the system oaa d%d 60 fimotiaa '0e UP& tank 41 in dw waste disposal system. MW Ply agree to su � � �St. ZODW Depafaent a mbficatiou torm, eiVW by dw owner and by a MMW •l�*ikpkmbcc. a 1loensedpontpervc 6friag9W(I)-tbeon -site wastewaterdinxmisystem is in paper 4mratin on and ,or (2) and pusapitag (if taecessary), the septic tads is Ieas than 1/3 NU of studes. Uwe, the mrdeaiVA4 read the above agroe to maintain the private sewage d4ml system with the standards sat forth. basi n, a: sot i6a Depaitiment flee Depart�t of Nature! Resource, State of Wiscotasita. Cer itkation Ming that rout septic has been mt�st completed and mt awd to tie St. Croix County Zoamg Office wido 30 days of ttm dues year M don date. 77 o&D �� SIGNATUM OF DATE I (we) certify i alt sametaunet totM true to the beet of my (our) kuowtedge. I (we) am (ace) lira ownor( :) of due Party described , by virtue of `i, sty recorded in Registor of Dccds Ofrwc, SIGNAIUREf OF AP DATE Any i4mnatis & flat b naffs - repeat *ay t(eg�t in the sanitary permit being revoked by the ?.owing Deparaneat. •••••• •« Include wits, this a lweation: a gum nty; ' d frog, the Register of feeds otnoc a copy tit M*410%lrvey map if reference is made in the warranty deed Vol 1624PAGC 80 6207 STATE BAR OF WISCONSIN FORM 3 -1998 KATHI...EEN H • WALSH RESTER OF DEEDS Document Number QUIT CLAIM DEED ST.;CROIX CO., WI RECENED FOR RECORD Russell D. Peterson, quit - claims to Robert J. Peterson and Diann M. Peterson, U-25 -2441 9:44 AM husband and wife, as survivorship marital property, the following described real estate in St. Croix County, State of Wisconsin: 01J3 1IM DEED EXEMPT 4 8 Lot 2, Rocky Ridge Estates in the Town of Somerset, St. Croix County, Wisconsin. C CE ER�<,COA.Y FEE: FEE: AND ; FEE: A parcel of land located in part of the Northwest Quarter of the Southeast Quarter RECORDING FEE: 14.04 of Section 1, Township 30 North, Range 19 West, Town of Somerset, St. Croix' 1 County, Wisconsin described as follows: Commencing at the North Quarter Corner of said Section 1; thence, on an assumed bearing along the north/south Quarter line of said Section 1, South 00 degrees 09 minutes 52 seconds West a distance of 3146.65 feet, this being the southwest Name in Area Name and Return Address corner of Let 1 of a Certified Survey Map recorded in Volume 7, page 2020 in the Register of Deeds Office in said County; thence, along the south line of last said Ronald L. Siler Lot 1, South 89 degrees 52 minutes 09 seconds East a distance of 42.84 feet to the VAN DYK, O'BOYLE & SILER, S.C. point of beginning of the parcel to be described; thence, continuing along last said Post Office Box 118 south line, South 89 degrees 52 minutes 09 seconds East a distance of 479.08 feet New Richmond, WI 54017 to the southeast corner of last said Lot 1; thence, South 00 degrees 09 minutes 05 seconds West a distance of 141.85 feet to the northerly right -of -way of a proposed 6y `� 3 2-�G► _�� p Town Road; thence, along said right -of -way, North 76 degrees 31 minutes 05 Parcel Identification Number (PIN) seconds West a distance of 118.91 feet; thence, continuing along said right -of -way This is not homestead property. along the arc of a curve, concave to the south, a distance of 53.40 feet, said curve has a radius of 233.00 feet and a chord that bears North 83 degrees 05 minutes 01.5 seconds West a distance of 53.28 feet;.thence, continuing along said right -of -way, North 89 degrees 38 minutes 58 seconds West a distance of 259.00 feet; thence, continuing along the northeasterly right -of -way of said road, North 43 degrees 24 minutes 21 seconds West a distance of 75.01 feet to the easterly right -of -way of 85' Street (a Town Road); thence, along last said right -of -way, North 00 degrees 23 minutes 42 seconds East a distance of 52.73 feet to the point of beginning. Dated this ? _ day of- Merek, 2001. Y _ *Russell D. Peterson * * AUTHENTICATION ACKNOWLEDGMENT Signature(s) STATE OF V49eONSTN 0 )SS. County ) authenticated this day of , 20 P rsonally came before me this _Z 6 t day of ,2114 / the above named to me known tp be the person(s) zvho c Sing * instrument and acknowledge the same. TITLE: MEMBER STATE BAR OF WISCONSIN (If not, authorized by § 706.06, Wis. Stats.) WAS DRAFTED BY Notary Public , Sta e o Wisconsin THIS INSTRUMENT Ronald W Si Commission s permanent. (If not, state expiration date: 20—iyx.) VAN DYK, O'BOYLE & SILER, S.C.Hlww+r�� P.O. Box 118 WESLEY H MILLER New Richmond, WI 54017 NOTARY PUBLIC • STATE OF (Signatures may be authenticated or acknowledge. Both are not necessary.) MINNESOTA My Commission Expires Jan. 31,20b *Names of persons signing in any capacity should be typed or printed below their signatures QUIT CLAIM DEED STATE BAR OF WISCONSIN FORM No. 3 -1998 INFORMA'i cON PROFESSh JA'_S COMPANY FOND DU LAC, WI 800 -055 -2021 Yap 162 PAGL X80 STATE BAR OF WISCONSIN FORM 3 -1999 KATHLEEN H. ?� H REGISTER OF DEEDS ST, ra�I Co., WI Russell D. Peterson, quit- claims to Robert J. Peterson a n, nd Diann M. Peterson, RECEIVED FOR RECORD husband and wile, as survivorship marital property, the following described 04 - 25-8001 9:00 AM real estate in St. Croix County, State of Wisconsin: QUIT CLAIM DEED Lot 2, Rocky Ridge Estates in the Town ofSomerset, St. Croix County, Wisconsin. COPY CERT T M PY fEE: A AND COPY rFF: CERT A parcel of land located in part of the Northwest Quarter of the Southeast Quarter T1'rAMSEER. ecion 1, Township 30 North, Range of St 19 West, Town ofSomerset, St. Croix P A SM. rNG FEE: 10.00 A&ESr 1 County, Wisconsin i! consin described as follows: Commencing at the North Quarter Cornerofsaid Section 1; thence, on an assumed bearing along the north/south Quarter line of said Section 1, South 00 degrees 09 minutes 52 seconds West a distance of 3146.65 feet, this being the southwest Fdress a corner of Lot 1 of a Certified Survey Map recorded in Volume 7, page 2020 in the urn Address Register of Deeds Office in said County; thence, along the south line of last said o Lot I, South 89 degrees 52 minutes 09 seconds East a distance of 42.84 feet to the OYLE &SILER, S.C. point of beginning of the parcel to be described; thence, continuing along last said south line, South 89 degrees 52 minutes 09 seconds East a distance of 479.08 feet x I I , WI 54017 to the southeast corner of last said Lot 1; thence, South 00 degrees 09 minutes 05 seconds West a distance of 141.85 feet to the northerly right -of -way of a proposed Town Road; thence, along said right -of -way, North 76 degrees 31 minutes 05 .2- /C - /e0 seconds West a distance of 118.91 feet; thence, continuing along said right -of -way Parcel Identification Number (PIN) along the arc of a curve, concave to the south, a distance of 53.40 feet, said curve This "n homestead property. has a radius of 233.00 feet and a chord that bears North 83 degrees 05 minutes 01.5 seconds West a distance of 53.28 feet; thence, continuing along said right -of -way, North 89 degrees 38 minutes 58 seconds West a distance of 259.00 feet; thence, continuing along the northeasterly right -of -way of said road, North 43 degrees 24 minutes 21 seconds West a distance of 75.01 feet to the easterly right -of -way of 85' Street (a Town Road); thence, along last said right -of -way, North 00 degrees 23 minutes 42 seconds East a distance of 52.73 feet to the point of beginning. arnr. Dated this day OfdMereh, 2001, /�� =� -" * ussell Det . Pcnon * * AUTHENTICATION ACKNOWLEDGMENT Signature(s) STATE OF w4seanN p )ss. County ) authenticated this _day of yp 1 y,, 477 rsonally came before me this Z3 " ` day of 240 -1 the above named to meknow to be the person(s) who executed the foregoing * instrument and acknowledge the same. TITLE: MEMBER STATE BAR OF WISCONSIN (Ifnot, t authorized by - §706 06, Wis. Sta[s.) THIS INSTRUMENT "'AS DRAFTED BY Notary Public, Sta D Wise nsin Ronald L. Siler Commission s permanent. (if not, state expiration date: VAN DYK, O'BOYLE & SILER, S.C. 20A.) P.O. Box 118 WESLEY H MILLER New Richmond, WI 54017 NOTARY PUBUC• STATE Of (Signatures may be authenticated or acknowtedge. Both are not necessary.) MINNESOTA 1 9 , 4 Commission Exom Jan. 31, 2001 *Names of persons signing in any capacity should be typed or printed below their signatures QUIT C'I.AIM DEED STATE uAR OF WISCONSIN FORM Na. 3. 19" INFORMATION PROFESSIONALS COMPANY FOND DU I.AC, wI 800- 655.2021 M.6C CZ 00 ! ,l£'999 :M'„6£ £2.00 s 0 / y J 1 * �, CC W C o �W / lt! ' = Z W -� Iti Cp to cv MCI =� os 3 � N� - a 3 „6£,£Z.00N 1 %4 �g I 'l ODi ,b0'L09 M a6£,£Z.00 S :,Bl£6l - -- �/ M .6�£,£Z.00 S �. 1 f � r I w 0 N O V z pE BZgON I 61- VZO , 4 �:. XP 40 3.SO,60.00N M.6£,£Z.00S I � aE1 L Al Ln ai Cb Z z OTC N / ,SC'tL* 3 „50,60.00 N — Il M „52,80.00 S = 8 � v � j M n; p I W I co �' p + I W co i N �W Wi W; I mw PLOT PLAN PROJECT Robert Pea rson " IDDRESS 1745 85th St. New Richmond Wi 54017 NW 1/4 SE 1/4S 1 /T 30 ]+V /R 19 W TOWN Somerset COUNTY ST. CROIX 7/26/02 4 MPRS Shaun Bird 226900 ,..• DATE BEDROOM CONVENTIONAL IN -GROUb PRESSURE CONVENTIONAL LIFT XXX HOLDING TANK MOUND SEPTIC TANK SIZE 1255 LIFT TANK SIZE763 DOSE TANK SIZE HOLDING TANK SIZE LOAD RATE .4 ABSORPTION AREA 1586 # of chambers 51 BENCHMARK V. P. Top of 1" PI ASSUME ELEVATION 100' Filter Zabel A -100 ❑ BOREHOLE O WELL *H. R. P. Same as Benchmark AL SYSTEM ELEVATION 98.8, 99.5,100.2- 3' Below Grade i f Standard Infiltrator Plans Designed Using Leaching Chamber Conventional Powts with 31.1 ft2 of Area Manual Version 2.0 Grade at System Elevation a 0 AL 3 -3' X 107' Cells with >3' Spacing Vents B-1 10' 12% Slope Huffcutt s Combo Tank B -3 c 15' 21' '$ Pro 4 15 B -2 Bedroom 55' House Vents 35' 20% B -5 20 Slope 130' B -4 84' 250' .e le 174th Ave NdRB Qi SEPTIC TANK & PUMP CHAMBER CROSS SECTION AND SPECIFICATIONS 4" Cl VENT PIPE 12" MIN. ABOVE GRADE WEATHERPROOF y ZS' FROM DOOR, WINDOW OR JUNCTION BOX APPROVED FRESH AIR INTAKE WITH CONDUIT MANHOLE COVER W / PADLOCK 6 FINISHED GRADE WARNING LABEL T p I vem. 4" MIN. 18" 9d C.Z. a IN. awtoa t. D. M�E ,'� is MIM. INLET WATER TIGHT SEALS GAS- �" TIGHT i '\/yjppROVED FILTER — A SEAL JOINTS WITH — ALM APPROVED PIPE APPROVED B ' ON 3' ONTO PIPE 3' — 1 — SOLID SOIL ONTO SOLID C SOIL PUMP OFF ELEV - FT. -J- OFF D 3 APPROVED BEDDING UNDER TANK CONCRETE PAD SPECIFICATIONS SEPTIC / DOSE DOSES PER DA TANK MANUFACTURER: NUMBER DO S GAL. DOSE VOLUME INCLUDING,/,Z C� TANK SIZES SEPTIC 6 J GAL. FLOWBACK: 71 S GAL. DOSE 7__� ALARM MANUFACTURER s v� C t ,G CAPACITIES: A = � � i INCHES = OI ,GAL. MODEL NUMBER: � 2 INCHES a GAL. B SWITCH TYPE: C = 1 INCHES = GAL• PUMP MANUFACTURER MODEL NUMBER: S D 2 � INCHES = /�Z GAL. SWITCH TYPE: REQUIRED DISCHARGE RATE 1 S GPM PUMP E ALARM WIRING AS PER ILHR 16.23 WAC / a— FEET VERTICAL QIFFERENCE BETWEEN PUMP OFF AND DISTRIBUTION PIPE '�'— FEET + MINIMUM NETWORK SUPPLY PRESSURE . . • • • ' ' FEET + FEET FORCEMAIN X ,2 0 FT /100FTOTALIDYNAMICAHEAD = /'FEET INTERNAL DIMENSIONS OF P TANK: LENGTH` WIDTH � : DIAMETER � LIQUID R .._._._ SIGNED: LICENSE NUMBER: 2 v J PAT E /���'� l /8s