Loading...
HomeMy WebLinkAbout020-1439-12-000 (2)Wisconsin Department of Commerce PRIVATE SEWAGE SYSTEM k­oUFRY. St. Croix Safety and Building Division INSPECTION REPORT Sanitary Permit o: GENERAL INFORMATION (ATTACH TO PERMIT) 633886 Slate Plan ID No Personal information you provide may be used for secondary purposes [Privacy Law, s 15 04 (1)(m)) Permit Holders Name' City Village Township Parcel Tax No Duane & Dana Jansen I TOWN OF HUDSON 1 020-1439-12-000 TANK INFORMATION TYPE MANUFACTURER CAPACITY Septic FX�S�in ies�� 000 Dosing 04. b./ lfl Aemlitfl- l1 Holding TANK SETBACK INFORMATION TANK TO PIT WELL BLDG. Vent to Air Intake ROAD Septic rX ;s Dosing Aeration Holding PUMP/SIPHON INFORMATION Al,,,A 011;tmr 237(o Manufacturer �7 C_C,.,e- (e f- Demand GPM Model Number T4 t 4,v TDH Li o0 Fricti oss _25 System Head TDH F ZZ' 3 Forcemain Len h3 t Diq.Z „ Dist to Well , SOIL ABSORPTION SYSTEM (otH C ELEVATION DATA STATION BS HI FS ELEV Benchmark It-iZb 11I.)l 9l0•�5 AIL B f cwa�' oz.z3 Bldg. Sewer l SVHt Inlet SVHt Outlet Dt Inlet Dt Bottom fin, � 87.3 z Hr/Man de De, ipe r �p•7 ilD�•y� Bot. System -� 10.5 I Oo . -r oz•N T'(o i•31 Io3• 6� 3.8 j&7 31 5 . 1 D .77 03. 0 •T (o (P.7 1 1 BED/TRENCH DIMENSIONS Width r Length ,� No Of Trenches PIT DIMENSIONS No. Of Pits Inside Dia Liquid Depth SETBACK INFORMATION SYSTEM TO ` /'t7V /L BLDG JI WELL LAKEISTREAM LEACHING CHAMBEROR UNIT Manufacturer /' •) 1 r ►Lr4 Y-O Ty p 01 System -r' Z C9r Jam' q ' __ Model Number E-L ;I�LS DISTRIBUTION SYSTEM i L" HeaderfManifold I Distnbution , x Hole Size 3 ' • x Hole Spacng Vent to Air Intake � Length_ _ Dia Length Dia Spacing G b ✓V�- SOIL COVER x Pressure Systems Only xx Mound Or At -Grade Systems Only Depth Over Bed/Trench Center y1 ' / { — h , Depth Over Bed/Trench Edges \ ` / I ` xx Depth of Topsoil xx Seeded/Sodded xx Mulched es ) Na Yes No COMMENTS: (Include code discrepencies, persons present, etc) Location: 794 SUMAC TRIL 1•t,, y 1 ) Alt BM Description - of 2.) Bldg sewer length = -amount of cover=lam Inspection #1: Inspection #2. —Vq_A+5 1eh/S vti lur s) n s 1-d os7 'et'c let , b. l'� e�va. 1 rz.Q 1-br.J ,rH lk cf,u 4W'LC A4S Plan revision Rfor ad do ❑Yes XNo y �/ Z I /') Use other side for additional informah n �' 'i G eL_e�....� !O SBO-6710 (R 3l97) Date Insepetors Signature Con No J /7n_. I,l in- '7.AaI ex 1 /lit SYS 1. Se dis as 2 All D Industry1400E ServWashington Counts tit (nn� g V 1400 E Washington Ave Ave —.. P.O. Box 7162 Swulary Pemut Numher uo he tillM in h5 Cn ) AUG 10 2021 MadlsBn, WI 53707-7162 6 33 8& St,mitApplicatio Mate TransactionNmn6cr n ePe In accordanc w1 >rd$d S(Dex ..ubmlvcron of this funs to t roprr.LLeg cn II e PW'FS-082100251-1 IS required p a 5anitar\ pCmnt Note Application Illlln5 tar SlallVKrK TS are >n flI — the Deplmnunt of Salery and Pmkssmnal Scrvlccs. Personal mfoovatlolt you provide ntm tf- r secondarx PrO ect Address (ddifTcreta than madmg address) IFses In accordancewuh the Pnvdcv Law, s 15 (A Ifni). . Slats 7-p Sumac Tmd I. A lication Information - Plense Print All information Property Owners Nmne Duane X Dana Jansen Parcel a n20-1479-I b0(x) Properts Ow ner's Standing Address Property Locatwn '94 Sumac Trail (iovl Lot NW 'a Nh 4l Section 2S Car State �— > 121p Hudson, WI Ctnic Phone Number C4016 - j Wide one) 129N 1t In 1'. orr If.T eof Building yP R(check all that apply) Lot = ® I or 2I anuls Dwcllmg- '.umber of Bedlm+nu � 12 Subdixnslon Name ❑ Public/Commercial Indigo Ponds - Descnhe I se _ ; 6IucA u ❑ City of ❑ State Owned - Descnhe Use —_... -. ❑Village of CSSI Numher ® Townof Iludwn 111. Tv eof Permit• Check onh tine box on line A. Com lete line B if a livable A ❑New System ®12epla;uncnl St.tent ❑ TrcdtmcnL l loldmg Tank Replacentcru ()th ❑ other Modl ficanon Id1"tun Fig Sx sicm (explain) 'crmd Number and Date Issued t. B. ❑ Permit Rencssal ❑ Permit Revision ❑ ( hinge of ❑ I'snna frmhfcr to New Before I xpimtion Plumber Owner S 1021 IV. Type of POWTS Sxstem/Coin oneril ice: Check all that appIN ❑ Nan-Pressurued In -(,round 1' curved In-l;n>w ❑ A14,radc ❑ Mound > 24 in of sunable soil ❑ Mound < 1_4 In of suitable soil ' ❑ Holding Tank ❑ Other Dupcndl (onigmem (explain) ❑ Pretreatment Llevicc lexplwn) I V. Dispersal/Treatment Area Information: Iksign Flow (gpd) Design Soil Appl1-91 t _ Dispersal Area Required isfl Dispersal Area Pmpused 1st) w System I Ievatum 450 Ratdgpdsq t+13 tJi I038' I023'. 10056' it 7 VI. Tank Info Cana, inr dOallons T pof 1 Po(�O1L-1 y New ianka Innung IenAs (iaotalllnnS Slartufaeauer 1;nlis — septicorlfoldmplank 1000 1000 1 Wieser Concrete ® ❑ ❑ ❑ l esmg Chamber 600 600 1 Concrete _Wieser V 11, Responsibility Statement- I, the undersigned, assume responsibdrh shown a for installation of the PONN IS n the attached plans. Plumtx:r s Namc (Pnnq Plumb - gm rc MP'MPRS Number Business Phore NumMs i V John Schmitt 7 lcvfi�/% �' 1'_77no 71i460-4ix6 Plumber s Address (street, C jiN. Shac. / Ip C ode l 586 Valley View Bail. Somerset. WI 54025 Vlll. County/Department Use Only Approved ❑ in, Perna Fee[' 6ws. inn Agcn�ignat re El nen Re--- or Dental $ .7�J�- �qZI/ 1\. Conditions Approv iR"Vmre+rr43"prtRal3> Q�n@s i�Q.— 0✓ EM OWNER: V'�°`tYr01..I'C—'9�r� � d�l+�•�x tic tank, effluent filter and ersal cell must be serviced / maintained % er management plan provided by plumber. T% Vim^^ 16 ids 6 1—_ hn '' V hly(,lt1p � for the •yerem and •umn the ('n^ , j{h ,�nyuPe not .Fhin tl i. 1 m he(,in we � as per applicable cod /ordlnan L.� .\L— V• (L� 6x 1 5) �Wn (rye �/�1/rde S Wlat n /na?Ce f . SYSTEM PLOT PLAN Jansen 3 Bedroom Replacement Dralnfeld Devgo now 4`0 GPD AUach Jes,V flop wIwhlwns for Project Address 791 Sumae Trail _ o commercaI plans y Bid 1 Symbol (K) BM Uc.e lac 56 n,5 �r�' O i Yqa: Malenal. :�ii 6+ Slaiward BM DesMoi T^- of .epi iar� aew -�„P Scale 1" = 40' Tables J84 N 3 8 384 30 5 1 0 <0 50 Sp BM2 S mool BM Elevation 1G2 23 4 C 1 a. P „ ---M •, � i — 841 Desu.pfor Top of =one. ele s ewak 81 Vie muse $lope Graoienl of 7e1Ptl Area Well <ymbol Of applicable) Noles See CSiA foe compk>le Oi Two ball valves installed to on old teas or new cells Provide instructions on management plan $ - Pre ure ary - — J — ' 7 7 -. - •,- UBIIZaLn BF -- --'�i--'-W-i,�`, Existing Ice valves Well i 01- - f -' --- 41 Valves . _i 73 B3 ■ g 71 T1 --- t, Existing 3 Bedroom Garage House ■ I Driveway 82 Existing ' 000/60C SepGdDose tank { T 1-3'x44' Quick 4 trench El =94 35' T2-3'x44' Quick 4 trench El =95 95' CXbT�1 ��rf T3-3'x44' Quick 4 trench El =98 05' U oq ' T4- 3'x45 EZ Flow trench El = 100 056' TS- 3'x45' EZ Flow trench El = 10 2 30' T6- 3'x45' EZ Flow trend El = 1C3 80' / • Borings by Thomas Schmitt ■ Bonngs by David Steel i. NOTE Maintain 50 Setback from well to drainf eld r, pP . A�,C August 9, 2021 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES:2023-08-09 Plan Review: PWTS-082100251-1 JOHN SCHMITT 586 Valley View Trail Somerset WI 54025 SITE: Duane and Dana Jansen 794 Sumac Trail St. Croix County Town of Hudson NW Y4 - NE Y4 -S25 —T29N— R19W FOR: DIVISION OF INDUSTRY SERVICES 10541 N RANCH RD HAYWARD WI 5043-W2 Contact Through Relay hnP/Idyp6.. 90 /prograrnsrmdusby-servioes YII/N.N93COntlrl.gOv Tony Ever* - Governor Dawn Cr4o - Seeretacv CONDITIONALLY APPROVED DEPi' OF SAFETY AND PROFESSIONAL SERVICES DIVISION OF INDUSTRY SERVICES SEE COKRESPONDENCE Description: Individual Site Design as allowed by Table 3 Bedroom In -Ground Pressure —450 GPD 383.22-1 — Replacement - 100" to limiting factor— Pressure Distribution Component Manual — Ver. Effluent Filter - Maintenance required 2.0, SBD-10706-P (N.01/01, R. 10/12) The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This system is to be constructed and located in accordance with the enclosed approved plans and with any component manual(s) referenced above. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06, stats. The following conditions shall be met during construction or installation and prior to occupancy or use: Reminders This approval recognizes the submitted plans as an Individual Site Design that does not conform to the approved "In -Ground Soil Absorption Component Manual, SBD-10705-P (N.03/01, R 10/12)". That is, the component manual does not allow the installation of in -ground systems on slopes >25%. This proposal has the cells on a 26.7% slope. There is an existing dwelling on the property served by a failing septic system which needs to be replaced. There is no way to avoid installing the POWTS in a steeply sloping area. The installer shall follow the plan directives laid out in the approved plan. The installer is responsible for installing this system in a safe and responsible manner to maintain the health and safety of personnel and equipment. The installer is responsible for ensuring the installation shall prevent seepage and breakout of wastewater moving laterally downslope of the cell. a Verify and adjust for uniform distal head pressure at each lateral to ensure equal distribution. • Two ball valves are being installed on force mains to both systems (the old and the new). Provide instruction in the management plan about how to operate these valves and at what times they will be turned. These valves must be accessible and protected from freezing. In addition, valves can greatly impact head loss. Be sure the pump installed operates within it's designed specifications after installation. • Ensure the existing septic tank is watertight, structurally sound and baffles are in place. Any changes made to the tank must be approved by the manufacturer. • A sanitary permit must be obtained from the county where this project is located in accordance with the requirements of Sec. 145.19, Wis. Stats. • Inspection of the private sewage system installation is required. Arrangements for inspection shall be made with the designated county official in accordance with the provisions of Sec. 145.20(2)(d), Wis. Stats. • A state approved effluent filter is required. Maintenance information must be given to the owner of the tank explaining that periodic cleaning of the filter is required. • A copy of the approved plans, specifications and this letter shall be on -site during construction and open to inspection by authorized representatives of the Department which may include local inspectors. Owner Responsibilities The current owner, and each subsequent owner, shall receive a copy of this letter. Owners shall also receive a copy of the appropriate operation and maintenance manual(s) and be responsible for ensuring that POWTS is operated and maintained in accordance with this chapter and the approved management plan under s. SPS 383.54(1). • In the event this soil absorption system or any of its component parts malfunctions so as to create a health hazard, the property owner must follow the contingency plan as described in the approved plans. • The owner is responsible for submitting a maintenance verification report acceptable to the county for maintenance tracking purposes. Reports shall be submitted at intervals appropriate for the component(s) utilized in the POWTS. In granting this approval the Division of Industry Services reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. The above left addressee shall provide a copy of this letter and the POWTS management plan to the owner and any others who are responsible for the installation, operation or maintenance of the POWTS. Sincerely, Cecel /? CeCe (Elizabeth) Rudnicki Wastewater Specialist/POWTS Plan Reviewer, Division of Industry Services (608)400-3186 elizabeth.rudnicki(@wisconsin.gov IN -GROUND PRESSURE CONVENTIONAL COMPONENT DESIGN INDEX AND TITLE PAGE Project Name: Jansen 3 Bedroom Septic System Owners Name: Duane & Dana Jansen Owner's Address 794 Sumac Trail WI54016 Legal Description: NWI/4, NE1/4, 525, T29N, R19W Township Hudson County: St. Subdivision Name: Indigo Ponds Lot Number: 12 Block Number Parcel I.D. Number 020-1439-12-000 Plan Transaction No. COIVDIHONALLP APPROVED DEPT OF SAFETY AND PROFESSIONAL SERVICES DIVISION OF INDUSTRY SERVICES Page 1 Index and title Page 2 Individual Site Design Page 3 Plot Plan Page 4 Septic & Dose Tank Specifications Page 5 Effluent Filter Information Page 6 Dose Tank Cross section Page 7 Pump Curve & Specificatins Page 8 System Sizing & Cross Section Page 9 EZ Flow Information Page 10 Pressure Distribution Network Page 11 Distribution Network Specifications Diagram Page 12 Existing Tank Certification Page 13 Management and contingency plan Page 14 Sanitary System Ownership/Address Form Page 15 Warranty Deed Page 16 CSM or Plat Attachment 1 Soil Evaluation Report Cep tea: SEE CORRESPONDENCE Designer: John Schmitt Licnese Number: MPRS 223760 Date: 7/15/2021 ,,,, Jf�j Phone Number: 715-760-0486 Signature: Z7% 1/L�/I/ (n-6round Soil Absorption Component Manual Version 2.0 SBD-10705-P (N. 01/01) Pressure distribution Component Manual Version 2.0 SBD-10706-P IN 01/01) Page 1 INDIVIDUAL SITE DESIGN JANSEN 3 BEDROOM INGROUND PRESSURE REPLACEMENT SOIL ABSORPTION AREA EXISTING POWTS DESCRIPTION: The existing soil absorption area consist of 3 Infiltrator Quick 4 trenches that are dosed. The trenches have failed as evidenced by effluent seeping out around the observation pipes when the pump cycles. PROPOSED POWTS DESCRIPTION: The existing soil absorption area is on a slope of greater than 25%. The proposed replacement soil absorption area will lie on a 26.7% slope. Due to the location of the well and a drainage easement on the property, this the best option available. The new cells will be installed with approximately 48 inches of cover on them. The depth of cover along with pressure distribution will keep the effluent from leaking out Each lateral will be identical other than the elevation, which will be dealt with by using ball valves to make all the squirt heights equal. The trenches will be installed by shelving along the hillside to make the installation safer. The back fill will be done with a track skid steer with greater stability than most machines Page 2 SYSTEM PLOT PLAN Jansen 3 Bedroom Replacement Drainfield Protect Address: 794 Sumac Trail am Symbol: A BM Elevation-96.85' BM Description: Top of septic lank finer cow BM2 Symbol: Q BM Elevation. 102.23' BM Description Top of concrete sidewalk at the house Slope Gradient of Tested Area: (26 7%) Well Symbol (it applicable) Notes. See CSM for complete lot Design Fkav: 450 GPO Attach design Mow calwlahons for commercial plans. Pipe Materials I ASTM Standard Tables 384.30-3 8 384.30-5 4" SCH 40 PVC pipe ASTM- D2W5 4" 3034 PVC Pipe ASTM-D3034 C, s Two ball valves installed to on old cells or new cells. Provide instructions on management plan. ------- Dfe rdi/ 86 ualizatin - Existing 107 --'- valves ---- ---- . Well 107• -- ------ V_aly-e� _ 105'�-- 7%E 3 WEI BM2 2 T1 Existing 3 Bedroom Garage House Driveway B2 BMt Existing 1000/600 SeptiGDose tank T1-3'x44' Quick 4 trench EI.=94.35' T2-3'x44' Quick 4 trench E1.=95.95' r T3-3'x44' Quick 4 trench EI.=98.05' T4- 3'x45' EZ Flow trench El.= 100,56' T5- 3'x45' EZ Flow trench El.= 102.30' T6- Tx45' EZ Flow trench El.= 103.80' 0 Borings by Thomas Schmitt ■ Borings by David Steel NOTE: Maintain 50' Setback from well to drainfield WLP1000/600-MR TANK SPECIFICATIONS n F DIMENSIONS: � o WALL 3' n a 4" CAST- -SEAL 4" CAST -A -SEAL BOTTOM: 3" COVER: 5' --- MANHOLE: 24' I.D. PRECAST CONCRETE RISER o ---- -- ----------� HEIGHT: 55' I I II II J I I '" LENGTH: 12-6 a w WIDTH: 7'-0" a q)`111' _BELOW INLET: 42" t ,- .TI LIQUID LEVEL: 36'oI QINflGHT: 14,970 LBS.IT 1i' 1 INLET AND OUTLET:t FILTER OR,1 1 4" CAST -A -SEAL BOOT OR EQUAL GASKET m o 0 BAFFLE JHI It ,I �I , INLET AND OUTLET BAFFLE AND FILTER: Itr ------_—---�---- --� WISCONSIN, SEE DETAIL /10 o o (OTHER STATES SEE CHART) W o N LIQUID CAPACITY: 27.88 GAL AN (SEPTIC) TOP HEW 16.76 GAL/IN (PUMP) C x Lo LOADING DESIGN: 8'-0' UNSATURATED SOILco C TANK CAN BE USED AS: 67 I SEPTIC/SEPTIC, SEPTIC/PUMP, ;k OR SEPTIC/SIPHON a o -4" VENT COVER: MIX DESIGN /8 (NO FIBER) W o co TANK: MIX DESIGN /1O (STRUCTURAL FIBER) W x N CUSTOMIZED TANKS: - ___ - FOR CUSTOM TANKS CONTACT WIESER CONCRETE } INLET - _ OUTLET �e �v p Z jj 1 Q I � REVIEWED BY $ n PUMP PAD REVIEW DATE a 0- DRAWINGS SUBMITTED N SIDE VIEW FOR APPROVAL APPROVED BY: SHEET N0. APPROVAL DATE: OF WKS ARE MANUFACTURED TO MEET OR EXCEED ASTM C-1227 REQUIREMENTS PRODUCTS NEEDED BY: / a Do 10 a paL �.qx, 7 Zabel PL-525 Effluent Filter PI -525 Filter The PL-525 Filter is rated for 10,000 GPD (gallons per day) making it one of the largest filters in its class. It has 525 linear feet of 1/16" filtration slots. Like the Polvlok PL-122, the Polylok PL-525 has an automatic shutoff ball installed with every filter. When the filter is removed for cleaning, the ball will float up and temporarily shut off the system so the effluent won't leave the tank. feature, • Rated for 10,000 GPD (gallons per day). • 525 linear feet of 1/16" filtration • Accepts 4" and 6" SCIID 40 pipe. • Built in gas deflector. • Automatic shutoff ball when filter is removed. • Alarm accessibility. • Accepts PVC extension handle. I'l -525 Intita Ila tit n Ideal for residential and commercial waste flows up to 10,000 gallons per day (GPD). 1. Locate the outlet of the septic tank. 1/16" Filtration Slots 10,000 GPD r-t 2. Remove the tank cover and pump tank if necessary. Accepts 3. Glue the filter housing to the 4" or 6" outlet pipe. If St'Hn an0 pipe the filter is not centered under the access opening use a Polylok Extend & Lok or piece of pipe to center filter. 4 Insert the PL-525 filter into its housing. 5. Replace and secure the septic tank cover. 1'I -SP Maintenance. The PL-525 Effluent Filters will operate efficiently for several years under normal conditions before requiring cleaning. It is recommended that the filler be cleaned every time the tank is pumped, or at least every three years. if the installed filter contains an optional alarm, the owner will be notified by an alarm when the filter needs servicing. Servicing should be done by a certified septic tank pumper or installer. 1. Locate the outlet of the septic tank. 2. Remove tank cover and pump tank if necessary. 3. Do not use plumbing when filter is removed. 4. Pull PL-525 cartridge out of the housing. 5. Hose off filter over the septic tank. Make sure all solids fall back into septic tank. 6. Insert the filter cartridge back into the housing making sum the filter is properly aligned and completely inserted. 7. Replace and secure septic tank cover. t-- Alarm Swatch (Optional) Accepts 1' PVC ,tension Handle Rated for 10,000 GPD 55 Linear Ft. of 1/16' Filtration Slots Certified to NSF/ANSI Standard 46 Deflector aGas Automatic Shut -Off Ball uw doors ui �I.Ivi %. ni., Polylok, ZaW- At Best filters accept the SmartFilterM switch and alarm. Easily installs into existing tanks Polylok. Inc. 3 Fairfield Blvd. Wallingford, C-r 06492 Toll Free: 877.765.9565 Fax: 203.284.8514 www.polylok.com Page 5 PAGE 5OF6 SEPTIC / PUMP TANK SPECIFICATIONS (No Scale) 4'O Pant F.pe >10 n tam Buildng Electncal must comply wnh 12" Min. or 2 0 ft above SPS 316 and NEC 300 Established Flood Elevelwn WeetneTrout EHend manhole near as necessary fNp�ll Approved Juntlwn Bas Approved LorAvg Manhole Cap IMPORTANT: vOnt Cep wth warring Label Alai l 1bpcao Anchor tank(s) as necessary c0r'd'° pursuant to SPS383.43(B)(g) 4•Minor20ftabove Established Flood Elevator, ItYP�I) 1 Finished G'ede CAPACITIES @ 16.76 gal/in z 1 a Depth (In) Volume (gal) A 18 301.68 B 2.0 33.60 [C] 5 83.8 D 11 1 184.36 *Pump Tank Liquid Level = 36 in Force Main Diameter = 2 in Force Main Length = 75 ft Force Main Void Volume = i2.23 gal j e T * H P e oa A LAW" 11 [y] Pump b_on Block 3'Approved Bedding Matenal sari Tank [C] Total Dose Volume (TDV) = 74.33 gal/dose `(5X total lateral void volume S TDV S 0.2X design flow) + (force main draklback volume) MIN. PUMP DISCHARGE RATE = 23.76 gpm Quick Dawnnen 16'MH Oyi Approved Jowls with Approved Ape 3 fl orao Si Ground (tvpol) 1 PUMP -OFF ELEVATION = 88.24 ft INSIDE BOTTOM ELEVATION = 87.32 ft Vertical Head = 16.48 ft + i Supply Head = 2.5 ft yy L 1.03 a/ + F Friction Loss = ft 1� + Fitting Loss" = .75 ft (min. suppy head x 0 3) = TOTAL DYNAMIC HEAD = 20.86 ft PUMP TANK. SEPTIC TANli Volume = 600 gal Total Volume = 1000 gal Manufacture Wieser Concrete Manufacturer(s): Wieser Concrete Pump Manufacturer. Zoeller Install approved effluent filter at the septic tank outlet Pump Model: 151 Or larqer 1seesttedtedwinnow".) immediately upstream of the pump tank inlet. Controls/Alarm Manufacturer: S.J.Electro Filter Manufacturer: Polylok Controls/Alarm Model: 101 525 Filter Model: NEW Float switches contalnina mercury are prohibited. obi - PUMP PERFORMANCE CURVE MODEL 151/1521153 MEN ■■WNI'�U,� ME Lim No ME utv 0 N m rY 7w, 260 24f Row rf .UU oi4sos4 CONSULT FACTORY FOR SPECIAL APPLICATIONS Turned dosing panels available Electrical altemators. for duplex systems are available and supplied with an alarm Variable level control switches are available for controlling single phase systems Double piggyback variable level float switdres are available for variable level long and short cycle controls Sear Owlk-Box available for outdoor installations - See FM1420 Over 130'F (54'C) special quotation required 1511i2"153 SeneS 15MMS3 MODELS I Comm sewcbw Modal yoMYpe Mode I Amp bueN N151 115 1 Non 6.0 1 2a3 BN151 115 1 Auk7 6c VKkWed _ 2cr3- E151 230 1 Non 32 t 2a3 BE151 230 1 Auto 32 hduded 2w3 N152 115 1 1 2m3 8N152 115 f j kouL 2a3 2 1 1 3 1 2 1Y1xJudN a3 n&ftB BN153 115 1 Wduded 2a3 E1373r1 1 2or3 BE/53 230 t krJalee 2v3 Sc•iEC'IVN CJIDc i Single pggyback variable level float swbch or double piggyback variable level float swft&. Reler to FMO477. 2. See FMO712 for coned model of Electrical Alternator E-Pak 3. Variable level control svntch IO-0743 used as acontrol achvaw. speofy duplex (3) or (4) Mat system. a, CAUTION TOTAL DYNAMIC HEADIFLOW PER MINUTE EFFLUENT AND DEWATERING MODEL 151 152 153 Foci: 14 o,i. tdan Gal. lxwa oa ue1Y 5 15 5[ 169 e9 Xi n 291 10 311 45 in 61 231 70 265 15 46 N 1M 53 mt 61 Mt 20 61 29 110 M 167 52 197 25 76 16 61 7r 1» 42 150 30 a1 23 67 33 i$ 35 107 _ - - n e5 W 122 1, 42 Slxld 14xd 30t 191m1 38t 01 brit "111134n 014 Models 1521153 ?vr 'Easy assembly" 0p 6d4tlrPYVe ntl Mrded t OPTIONAL PUMP STAND P N 10-2421 Reduces potential dogging by debris Replaces rocks or Docks under the pump Made of durable, nonoonosive ABS Raises pump 2' oil bottom of basin Provides the ability to raise intake by adding sections of 1 %; or 2' PVC piping Attaches securely to pump Accommodates sump. dewatering and effluent applications NOTE: Make slse Bost is five from obstruction. RESERVE POWERED DESIGN For unusual conditions a reserve safety factor 1s engineered into the design of every Zoeller pump. ® Copyright 2010 Zoeller Co. All rights reserved. Page 7 IN -GROUND PRESSURE DISPERSAL AREA Stepped Elevation Trenches with EZ1203HP Bundles 3-ft Trench (down -sizing credit) min 12" (Hacal) SOIL COVER 12' mn trench depth MwmO TYPICAL TRENCH CROSS SECTION VIEW (No Scale) Highest Trench Lowest Trench (as applicable) System Elevations = 103.8 ft, 102.3 ft; 100.56 ft; ft; ft Provide minimum 3 It separation between trenches. Lateral Invert = 104.3 ft; 102.8 ft; 101.06 ft; ft; ft Elevations TYPICAL TRENCH (Show force main, manifold, and flush valve locations on plan view.) PLAN VIEW 1.5 ^0Schdl40 otee.b.PWashcdlbenabMd atpnchmt»Mean Iwounft 10 ft (NO Scale) PVC Lateral observation Pipe (typical) Observation (NP A) I I see M�e�c� eec c suscc cscc�cca I' g= 45 It ------ ----- � (typical) INSTALL PER TRENCH: 4 10-ft bundles @ 50 fe EISA/unit = 200 + 1 5-ft bundles @ 25 IF EISA/unit = 25 �A=3.0 ft Oyrwcal) EZ1203H Bundle (typical) ft' (mfd by Infiltrator Systems, Inc.) Install pursuant to manufacturer's instnlctions ft' = Proposed EISA per trench = 225 ft' Required Infiltration Area = 643 ft2 x 3 trenches = Proposed Total EISA = 675 tY Installation Instructions for EZflow Systems in Wisconsin Wisconsin Department of Commerce, Safety and Buildings Division, has reviewed the specifications and/or plans for this product and determined it to be in compliance with chapters Comm 82 through 84, Wisconsin Admin. Code, and Chapters 145 and 160, Wisconsin Statutes. All sites must meet the Site & Sod Conditions & Locations & Isolation distances as noted in local regulations, The approved products are 1203H (3-12' bundles with pipe in center bundle in 5' or 10' lengths) and 1203HP (3-12' bundles with pipe in each bundle in 5' or 10' lengths. A single pipe bundle contains a four inch perforated pipe sur- rounded by EPS aggregate and is held together with poly- ehtylene netting. A single aggregate bundle contains aggregate only and is held together with polyethylene netting. Materials and Equipment Needed • EZflow Bundles • EZflow Geotextile Fabnc • EZflow Intemal Pipe Couplers • Pipe for Header and Inlet • Backhoe/Excavator Installation Instructions The instructions for installation of EZflow products are given below. This product must be installed in accordance with state rules defined in chapters Comm 82 through 84, Wisconsin Ad- ministrative Code, and Chapters 145 and 160, Wisconsin Stat- utes, as well as the local health department's current design manual. 1. After the local health department has determined sizing, configuration, and layout for the EZflow systems, stake or mark with paint the location of trenches and lines. Be careful to set correct tan., invert pipe, header line or dis- tribution box and trench bottom elevations before instal- lation of pipe bundles. 2. Remove plastic EZflow shipping bags prior to placing bundles in the trench(es). Remove any plastic bags in the trench before system is covered. 3. This product must have geotextile fabnc that meets re- quirements of s. Comm 84.30 (6) (g), Ws. Adm. Code, installed directly on top of the product and extending down along the sides of the product to a point at least six inches from the bottom of product. 4 When installed In a trench, the trench should be dug to a width of 36 inches. This not only saves labor in excava- tion, but also provides better load -bearing capacity after backfilling is complete. t*EZflown ►y INFILTRATOR 5. The Absorption area (SF) necessary for a given site shall be sized based on maximum daily sewage flow (GPD) and the Permeability for the site. If certain criteria is met, the EISA sizing can be used in Wsconsin, resulting in a 40% smaller drainfield. 6. Place EZflow bundles) in the EZflow configuration ap- proved by system design permit specified for the parbcu- tar site. The top or center -most bundles containing pipe are joined end to end with an internal pipe coupler. Any additional aggregate only bundles that may be required, • should be butted against the other aggregate -only bun - dies and do not require any type of connection. 7. The top of each GEO cylinder contains a fitter fabric pre - manufactured in between the netting and aggregate. The fabric is inserted to prevent soil intrusion. The installer shall make sure the the GEO is positioned upward and is in contact with the fabric contained in the adjacent cylin- der before backfilling. 8. The EZflow Drasnfield Systems should be installed in a level trench In all directions (both across and along the trench bottom) and should follow the contour of the ground surface elevation (uniform depth), with all continuous adjoining 10-foot cylindrical bundles placed end to end, with central bundle distribution pipe interconnected, without any dams, stepdowns or other water stops. 9. The trench top shall be graded such that water will not pond. Backfill should be seeded or sodded immediately after completion to reduce erosion. 10. EZflow EPS bundles are flexible and can fit ,n curved trenches as may be necessary to avoid trees, boulders, or other obstacles. 11_EPS aggregate is lighter than water, therefore, it might be expected that natiral buoyancy forces would tend to cause EZflow assemblies to float out of ground when bonding occurs. Field experience has shown, however, that this is not a problem when systems have a minimum of 6' of soil cover as recommended by manufacturer. 1203H-GEO n",r^%tile Material Page 9 PRESSURE DISTRIBUTION NETWORK, CELLS T4-T6) : 1. Distribution pipe sizing • Soil Absorption Area • Lateral per area: 3 • Lateral spacing: 7.00' • Lateral length: 45' • Lateral size: 1 1/2" • Orifice size: 3/16" • Orifices per lateral: 12 • Lateral discharge rate: 7.92 qpm • Distribution network discharge rate: 23.76 qpm 3 laterals x 12 orifices/lateral x 0.66gal/orfice = 23.76 gpm 2. Manifold • Location: Center • Length 7.00' )N • Diameter 2" • Friction loss: 14' x 1.270ft/100ft = 0.18 ft 3. Force main: • Diameter: 2" • Length: 75.00ft • Flow rate: 23.76 qpm • Friction loss: 75' x 1.27ft/100ft = 0.95 ft 4. Total dynamic head: µaa, / Frly-tin LOSS /I -- . J0 -p f.03 • Minimum supply pressure: 3.25 ft • Vertical lift: 16,48 ft • Friction loss (forcemain) 0.95 ft • Friction loss (manifold) 0.18 ft • Total dynamic head: 20.86 ft Ball valves will be used to equalize the pressure between the laterals. Page 10 DISTRIBUTION NETWORK SPECIFICATIONS (No Scale) Laterals to be level Schiff 40 PVC Lateral 0 = 1.5 in FLUSH VALVE DETAIL (typical) (No Scale) Orifice in — Valve Box Center of Threaded Cap (insulation optional) for Head Testing (optional) \ \ r Shield orifices for t ) \ gravelless applications Ball Valve I \ (optional) Orifices equally spaced: \ _ [[c-h-e7ck a) OR b) below] a) }�, along bottom of lateral ' \ bl io t f lateral Flush Valve "0 Schdl40 PVC Force Main (dyer pipe / (slope to pump tank optional) for drain -back) YrALV� I=Ck �GUAL/Zi/t:t I` KC SSt,7 l�L' Lateral Length (P) = 45 It Number of Orifices per Lateral = 12 Orifice Discharge Rate = .66 gpm Number of Laterals = 3 a ng opo with every 5 th hole Assembly - Lateral Discharge Rate = 7.92 gpm facing down (typical - see detail) Last Orifice Orifice Spacing (X) = 45 in (typical) (typical) TOTAL DISCHARGE RATE = 23.76 GPM LATERAL INVERT ELEVATION = 104,31 102' & / 1 01.5G Odfice Diameter= •188 in (typical) (typical) First 04W OBSERVATION PIPE DETAIL (No Scale) Screw -Type or-,i.:�,. Slip Cap (loose) W Finished Grade (mulched & seeded) 4"0 PVC Pipe ` i ;;. Topsoil Cover Top of pipe to terminate (min. 1 foot) at or above finished grade (4) 1/4"-1Iz" X 6" Slots - 30 apart Anchoring Device Infiltration Surface (typical) - �--- x END MANIFOLD z 0 Check CONNECTION applicable box. Mangold First Orifice (riser pipe optional) (typical) i-- X--}--X/2 - X/2-- it X ltyW�q (typical) CENTER MANIFOLD Mpeiopti ❑ CONNECTION (riser pipe optional) S1 . ( ROI\ ( of V.I) Zo.NI\G UFFI( 11. ilIIFK 1 I ION STVI ENIEVI FOR t I IIAZ.lk I IU\ OF I' \Is I I\(; sf.vi I( 'I k\h(ti) I111N U It, l:lllt\ Ill,tl I I;,IA. I : I , I),LIuI I!'.i iAI.11'1L' .ihUk , I I I 1 1 ul iIAIIL ',In1, hlr,int � .�I'l III the I„i tt�t lll,' IC. tlCil u•. �tli Ull it dt uti•. ,. .- •. �CCut,i; 1-I t+1+n � A. R.utcr ' ' �', . I,tAAIl kit tit (liltA CI�unn A11,�i,nan poll nt.l-irruun I crruft th,u I h,I� tound Ihr I,u11.1.t It, the hr.l ttl ntv "'I'll% Iic1�_C, 1AId L011it)t"llt !0 Ijl. 111, of 1)'ti =L,4 inn I: tOIL%I 111TV,1111I Ito hl lun,!IkI 1'1L 11IUhcl�\ \101 I1:. CI11 ILIIL , I!l1hi1:llI,'1 ,11 112" i.i I)Id LIIU l,l.k ,4.L11 il1111, d l,ol 1)(14111 �v'toll �klll❑CV 411c , �111�nIyInt,ur �ttlllnlC nr Iru,dll oI 11u1r .I tl il� (,111JCII\ ( 11111'IU�IItlll P(:1,11) ( llllLl,I, 11�� \1xlo,I.IUICI III l,llt't11'.I t, I.1n6 1 1 11,,tkn \t � ,'.I nn. 1111111CC, WILT 11 I I C-I1 II, L I NCLI PIIII-111Cf til, n,Itu!;I IP[Ilit A,IILCi „vt<- ITulcl C« II ALIIIII)CI l %IP MIT" Mill Its hC :oII1j1ICIcd h\ iLdltl Ctl It1tlllll-ki1 (I)Clll of .I.I CtA .II1,1 PII1lC..it'11.11 till A ILI" ( 11a1)lw jI Il ,tlld 1 141 1111_ �`k IIt nihlll '1(JttJC11 01 111Ci11CLl dIS11ONC1 (\IZ 1 1" LLoll,III \ t I I 1 L l 1 1.i 1, t l lI di, I I�il _'O12 PAg: l: In -Ground Pressure Management Plan IMPORTANT: PAGE 6OF6 The owner of this in -ground pressure system shall be responsible for its perpetual operation and maintenance pursuant to requirements of SPS 382-384, Wisc. Admin. Code. Pursuant to SPS 383,52 (2), Wisc. Admin. Code, this system shall be considered a human health hazard if not maintained in accordance with this approved management plan. Furthermore, all inspection and maintenance activities shall be performed by a registered POWTS Maintalner in accordance with SPS 383.52 (3), Wisc. Admin. Code. Maximum Dispersal Area Operating Limits: Design Flow = 450 gpd; BOD5 5 220 mgL"; TSS 5150 mgL"; FOG 5 30 mgL" Inspection Checklist INSPECT EVERY 3 YEARS o type of use o age of system o nuisance factors (i.e. odors, user complaints, etc.) o mechanical malfunction (i.e., pumps, valves, switches, floats, etc.) o material fatigue (i.e., leaks, breaks, corrosion, etc.) c solids volume in anaerobic treatment tank(s) and any distribution appurtenance(s) (i.e., distribution / drop boxes) c neglect or improper use (i.e., exceeding design capacities, prohibited activities, etc.) c extent of ponding in distribution cell prior to dosing dosing irregularities (i.e., pump re -cycling, float switch settings, etc.) o electrical components (i.e.. wiring, connections, switches, controls, timers, alarms, etc.) o distribution lateral or lateral orifice plugging (measure lateral distal pressure — compare to design specification) o surface discharge of effluent or sewage back-up into structure served Maintenance Checklist MAINTAIN EVERY 3 YEARS (or when necessary) o Seotic and dose tank(s) shall be pumped by a certified septage servicing operator licensed under s. 281.48 Wis. Stats. when the volume of solids In the tank(s) exceeds one-third (1/3) the liquid volume of the tank(s) or as required by local ordinance. Disposal of contents shall be pursuant to NR 113, Wisc. Admin. Code. o Effluent flKerls) shall be inspected every 3 years and shall be cleaned when necessary to remove any accumulated solids according to manufacturer's specifications. A servicing period will always be greater than 12 months. c Distribution laterals shall be flushed once every 3 years or when necessary. System maintenance reports shall be submitted to the proper local government unit in accordance with SPS 383.55 Wisc. Admin. Code. Report any component failure or malfunction to: Name of individual or company: Local government unit: Local government unit address: Phone: Phone: IF41M Any defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1), Wisc. Admin. Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383, Wisc. Admin. Code. No product for chemical or physical restoration of the POWTS may be used unless approved by the department in accordance with SPS 384, Wisc. Admin. Code. Contingency Plan In the event that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant to a plan submitted to the appropriate agency for review and approval. A failed in -ground dispersal component may be abandoned and replaced by a code -complying dispersal component in a pre -determined area of suitable soils. System Abandonment If use of this POWTS is discontinued, it shall be abandoned in accordance with SPS 383.33, Wisc. Admin. Code. Page 13