HomeMy WebLinkAbout018-2019-78-000 (4).consm Department of Commerce PRIVATE SEWAGE SYSTEM County St. Croix
afely and Building Division
INSPECTION REPORT Sanitary Permit No:
(ATTACH TO PERMIT) 633967
GENERAL INFORMATION State Plan ID Nol
Personal information you provide may be used for secondary purposesPrivacy Law, s.15 04 (1)(m)]-�-
[Permit Holdefs Name City Village Township Parcel Tax No
Rolling Hills Farm Owners Association I TOWN OF HAMMOND 018-2019-78-000
CST BM Elev Insp BM Flew BM Descn n' Secbon/TownlRange/Map No
167.10lo ivy l 29.29.17.1278
TANK INFORMATION
TYPE
MANUFACTURER
CAPACITY
Septic
Dosing
t �� `R
7�
1 Z 5�0
Aer
H mg
TANK SETBACK INFORMATION
®�----I-
PUMP/SIPHON INFORMATION
Manufacturer
rE
Demand
yy
Model Number
TDH
Lift i.,!')
Fnct n o� \b
System Head
TDH Ft
Forcemain
Length I
-- Iti5
Dia. ❑
Dist to Well
SOIL ABSORPTION SYSTEM / , , I
ELEVATION DATA
STATION
BS
HI
FS
ELEV.
Benchmark
, �
I0�o
1
U
t1J to
Alt BM
Bldg. Sewer
NIA
SUHt Inlet
Sf/Ht Outle
t nlet
9.36-
to32.io0
Dt Bottom
1-2.
ozgry
Header/Man.
34, f
103g 32 r
Dist. Pipe
B System
.t{Z
O
L7e lap -
St c/ err
lb �vr Q
--77e
.L61p31,.-5
wn.iwte,
$..
3.zq
038
E REtICtT
ENSIGNS
Width
y
Length
No
PIT DIMENSIONS
No. Of Pits
Inside Dia
epth
SETBACK
SYSTEM TO
P/L
LDG
LAKE/STREAM
LEACHING
Ma cturer
INFORMATION
CHAMBER OR
UNIT
Type Of System
(-\ZF
/
del Number
t,M.Olc)
DISTRIBUTION SYSTEM /
Header/Manif Id \ tt
`l1
%�tp
Disinbution
p ()
I L
(
y/
x Hale
ize
fl
r/_
7(!
®
x Hole Spacing
/
Vent to Av Intake
Length Dia
Length
•� DmIL Spacing
{'
31I,(
2
a. S
SOIL COVER x Pressure Systems Only xx Mound Or At -Grade Systems Only
Depth Over
Depth Over
xx Depth of
xx SeededlSodded
xx Mulched
BedlTrench Center
Beifrrench Edges
Topsoil
—
J Yes No
'Yes 'L No
III(IMENTS: p(I I code discrepencies, perrsons presant, etc) Inspection #�. �,v� 5 °I n�' ; I Inspection #�) 1/l l
n: Noress vra�-`la�bl,[71�_wtQi (/Q.wC9tl�l�l�2E/i./nr'19te fAvGf� /.C) /. jelDP tea( il%
1.) Alt BM Description = u
2.) Bldg sewer length = /✓plir
- ""ri of cover �0V `
ftidL
Plan revision for add? _ io No �p 2/iz02-
,�,f� pte heic�e for additional info ion Fy ���_jf
4981bh6 1 �eN'-�IE!""ors Signature
�tl�jPr.r,ta'l.Pl i�t�i over su�,os (
Cart No.
N- Q
County
Safety and Buildings Division
201 W. Washington Ave., P.O. Box 7162
St. Croix
Sanitary Permit Number (to he filled in by Co )
"ct. '_
Madison, WI 63707-7162
&3396-
SEP 302021
�r�' nP g1t Application
State 'InansachonNumber
In accordance with PS I
, mission of f ul form tot a alip unit
072101727-C
(3`83
is required pnor too U& ry permit Note Application turns for state-o%vned POWI Sue submitted to
Project Address (if different than mailing address)
the Department of Sa cry and Professional Servies Personal information you pmv ide may be used for secondary
purposesin accordance with the Privacy Law, s 15 (4(I m), Stats
. / ^
Al �'(
1. Application Information - Please Print All Information
Property Owner's Name
Parcel N
Rolling Hills Farm Owners Association Inc. N Ex
018-2019-78-000
Property Owner's Mailing Address
Property Location
3435 Labore Rd. Ste 150
Gryt Lot
SW y, NW / Section 29
City, State
Zip Code
Phone Number
Vadnais Heights, Mn.
55110
(circle one)
N, R 17 Ii orQV
- _- —
11. "type of Building (check all that apply) 12
Lot N
Subdivision Name
Rolling Hills Farm
I or 2 Family Dwcllm Number of Bedrm s
�3 LAs
1 &20
Block #
c/Commercial - Use
❑ PubhDescribe
❑ City of
❑ State (honed - rescnbc. Use
❑ Village of
CSM Number
N lawn of Hammond
III. Type of Permit: (Check only one box on line A. Complete line R if applicable)
® New Svstem
❑Replacement Svstem
❑ Treatment Holding Tani: Replacement Oniv
❑ Other Modification to Lxistmg S�Stem (explain)
B.
❑ Permit Renewal
❑ Permit Revision
❑ Change of Plumber
❑ Permit "transfer to New
List Previous Permit Number and Date Issued
Before Expiration
Owner
IV. Type of POW7:S S stem/Con nent/Device: Check all that apply) .�
❑ Non -Pressurized In -Ground ❑ Pressurieed In -Ground ❑ At -Grade )U Mound> 24 in of suitable sod ❑ Mound <24 in of suitable soil
❑Holding Tank ❑ Other Dispersal Component ai) Pretreatment Dev ice(evplam) CU 4"t�1Jr
V. Dis rsallTrcatment Area Information,
Design Flow (gpd)
Design Sod Application K 1) I
Dispersal Area Required (st) Dispersal Area Proposed (sf)
System Flevatio ry f
lP^
1800
1.5 .6 11200
1200/3057
103 .50 p ,
VI. Tank Info
Capacity in
Total
p of
Manufacturer
Gallons
Gallons
Units
2 Sim tex fifers
c u
u
-
VewTaziks
_
Septic or Holding Tack
nosingCha'rber
1250
1250
1
Wieser
x
V If. Responsibility Statement- 1, the aadenigned, ruitin-44-P pAilitivfo4astallation ol the POWTS shorn on the attached plans.
Plumbers Name (Print)
Plu ignat
MPIMPRS Number
Business Phone Number
Keith Knudtson
64W36517470-1737
Plumbers Address (Street, Citv. State, Zip C .
927 150th St. Roberts,Wi. 54023
V I ll. CountyAllepartment
Ilse Only
XAPpmved
❑ Disapproved
Permit Fee
,rt''!/s/
Dat'�
Iss m Agent Signature
❑
mat
IX. Conditions Approve alesl)isappreual Z` I _20 j
SYSTEM OWNER.
Septic tank, effluent flier and t t/'Y�`/$�t.TV'D�(l-
GC+2 Uti-
dispersal cell must be serne.•d /maintained �) A �l „- . n ,�„h pS A� 1~��
as AA
as per management by
�>�t
plan proe .Jed plumber.
w���
!
26MSOAA
as Per app l icaicab!I e cod e'•UIUIIICIIC�J' aplan for thes"le into eCoaot:o on paper not kss SirBia Ii�s¢ebk t tnFer"A47`� �o P s Qoaoua ice.
N� 1043.48' DWF = \
N 600 gp
c� L.80= E
N 1040.40 yyF =
Sanitary Site Plan - $ FN# 1624
For: Rolling Hills Farm o� WE , . 7a e�
Residential Property Owners Ass. Fa FN# 162z r2-
Outlot ]-in the SW114 akd NW114
I See. 29 T29NRl7W . a
PN0'
Town of Flammond - St. Croix County 1g� .1b
I
� 70.01' C38
N �
C8 __l_r/ C7
6 N S88°19'02'NV
1 70.01' FN# 1121. ,vcu•
Proposed Proposed
BM ELEV FN# 1619 WELL DWF
1036.01 FN# 1617 p 600 GPD o
•Proposed WELL P GpD ems,
6 0 LOT m
0 40 e0 Typical of each lot will be a 4" Sch. 40 PVC Bldg, Sewer DWF 78 N
and the placement of a Hoot H-600A B&o./Septic 600 GPD m 21781 N
G°phic Sc0. (Faal) N, so Fr n, SQ7�
1 mat - so rt. N LOT
1036.501 > 19
1037.00' LOT m m
1035.00' N 20 \ N 4" PVC Bldg,
OUTLOT 1 \\` o er
(Sch 40 Typi
21 B1
29.56 ACRES Open Fallow Field Site N so Fr. 60
N Proposed Hoot �00.
1,287.641 SQ. FT. w H-600ABio./Septic
erP Proposed 8' x 150' Mound Dispersal Cell 16, 1042.62' 0�
�^ located along the 1036.50' contour wta S.E. of 1037.501 g5.
1044.50'
O 10 7.19' 3 1
6
\/1, FN#
k
LOT
16
LOT N `
17
wo
—1
m
rfl
21,761 �\
sa Fr
#2 1 Proposed 4" Sch, 40 PVC or Astm -D3034
HM Conveyance Pipe Typical
I_ Mound to ° Proosed Wieser Concrete W1250-MR Dose
Serve Lots Tank w/ Simtech STF 100 In -line Filters
H.W.L. 1027.7 18,19 + 20 Proposed Two 2° Sch,40 PVC F.M.
BM#1 = Top of Wooded Hub NW Corner of Easement #6
Con rol Pt. # 2010 Elev, = 103.7,66'
BM#2 = Top of Wooded Hub NW Corner of Easement #6 Existing Sanitary System for Lots 15-17
Contro Pt. # 2009 Elev. = 1033.90,
2„81
so er
0
t
i ;�tPAft1'AfF l T
0
/r/s
ASP
I
S /V l
nk . tita
July 27, 2021
CONDITIONAL APPROVAL
PLAN APPROVAL EXPIRES- 2023-07-27
Plan Review: PW'TS-072101727-C
KEITH E STONER
23220 Woodcreck Rd
Siren W 1 54872
DIVISION OF INDUSTRY SERVICES
2331 SAN LUIS PL
GREEN BAY VJI 54304-5211
Contact Through Relay
http'Rdsps vri.gov/programshndustry-services
ww.v.wlscons n.gov
Tony Evers - Governor
Dawn Crim - Secretary
Condrhonally
APPROVED
DEPT OF SAFETY AND PROFESSIONAL
SERVICES
DIVISION OF INDUSTRY SERVICES
SEE CORRESPONDENCE
SITE: Rolling Hills Farm Lots 18-20 Shared Sanitary System
1621 '-'lid �%c
Town of HAMMOND
St. Croix County
Total Amount: $325.00
Pressure Distribution Component Manual — Ver. 2.0,
SBD-10706-p (N.01/01, R 10/12)
Mound Component Manual— Ver. 2.0, SBD-10691-P
(N.01/01, R 10/12)
Description: 1800 GPD (/2 Bedrooms — New Construction — Pretreatment)
Maintenance Required
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes
and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This system is to be
constructed and located in accordance with the enclosed approved plans and with any component manual(s)
referenced above. The owner, as defined in chapter 101.0 1(10), Wisconsin Statutes, is responsible for compliance
with all code requirements.
No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06.
stats
The following conditions shall be met during construction or installation and prior to occupancy or use:
• The department mop require meterin;; (r ntonitu61W, of the effluent trt1r11 thn Prr,duet to eN dluatc the
of"I'TT ll wid ��m•� h ri,. 1,, �I'ti : �.; -441 U1Urnt ruJLt% I)a,artItc,
• 1 salid maintenance'sen icinS Cunh-art 1, rcyuu�:d for t4a lit, n` the .}amll. \ C7p\ ufthe unnal nanalit_s nl
c, ntta.t Milli " .0 h111IUCII nI the II Lll t P1I� I t„ n.tcm�r ,Tthe �anitai heruut hX the permit is-ume ❑cent
• Preserve dispersal area prior and during construction to avoid disturbance, compaction and use of the site.
• With new construction; it is recommended not to activate the pump in the dose tank until the tanks are
pumped prior to homeowner occupancy.
• Wastewater generated from contractors cleaning of equipment and tools and/or left over construction
products shall not be discharged into the drains discharging to the private onsite wastewater treatment system
(POWTS). Waste generated shall be properly disposed of on -site or off site.
• Any tall grasses, leaves and shrubs shall be cut short and removed prior to tilling the surface for installation to
prevent matting under the dispersal area. All loose organic material to be removed from POWTS Dispersal
Area.
• Divert surface water from all POWTS Areas.
• Prior to construction of the dispersal area, check the moisture content of the soil to a depth of 8 inches.
Smearing and compacting of wet soil will result in reducing the infiltration capacity of the soil. Proper soil
moisture content can be determined by rolling a soil sample between the hands. if it rolls into a 1 /4- inch wire,
the site is too wet to prepare. If it crumbles, site preparation can proceed. If the site is too wet to prepare, do not
proceed until it dries.
• All piping shall conform to SPS Table 384.30-3 and SPS Table 384.30-5
• Insulate building sewer beyond 30 feet per SPS 382.30 (11)(c)
• Well setbacks to meet chs. NR 811 & 812
• Tank Installation to follow all manufacture's recommendations.
• Verify property line(s) prior to installation.
• Pump Floats to be set and verified per approved plan. Any changes may result in pump resizing to meet
TDH and GPM Specifications.
Owner Responsibilities
• The current owner, and each subsequent owner, shall receive a copy of this letter including instructions relating
to proper use and maintenance of the system. Owners shall receive a copy of the appropriate operation and
maintenance manual and/or owner's manual for the POWTS described in this approval SPS 383.54(1).
• In the event this soil absorption system or any of its component parts malfunctions so as to create a health
hazard, the property owner must follow the contingency plan as described in the approved plans.
A copy of the approved plans, specifications and this letter shall be on -site during construction and open to
inspection by authorized representatives of the Department, which may include local inspectors. All permits
required by the state or the local municipality shall be obtained prior to commencement of
construction/instal lation/operation.
In granting this approval the Division of Industry Services reserves the right to require changes or additions should
conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review
shall relieve the designer of the responsibility for designing a safe building, structure, or component.
Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address
on this letterhead.
The above left addressee shall provide a copy of this letter and the POWTS management plan to the owner and any
others who are responsible for the installation, operation or maintenance of the POWTS.
Thanks,
POWTS Plan Reviewer— Wastewater Specialist
Department of Safety & Professional Services I Division of Industry Services
email: tim.vanderleesbu,wisconsin.eov
Cell: 608-516-6134
Index and Title Sheet
Project Name: Rolling Hills Farm Shared Sanitary System for Lou 18-20
Property Owner: Rolling Hills Farm Residential Property Owners Ass.
Address: 3435 Labore Rd.
Vadnais Heights MN 55110
Legal Description: Part of the SW IA and NW I/4
Section 29T29N-R17W
Township: Hammond County: St. Croix
Subdivision Name: Rolling Hills Farm Out Lot 1
Comp. #/Parcel ID: 018-2019-78-000
CONTENTS
Page: I Plan Narrative
Page: 2 Plot Plan
Page: 3 Mound Plan View and Cross Section
Page:4 Lateral Layout
Page: 5 Dose Chamber Cross -Section
Page: 6 Pump Curve
Page: 7 a I-b Duplex Pump Panel Specifications
Contlmonally
APPROVED
DEPT, OF SAFETY AND PROFESSIONAL
SERVICES
DIVISION OF INDUSTRY SERVICES
SEE CORRESPONDENCE
Lou: Sanitary System Serving Lots 18-20
Page: 8 Hoot Systems H-600A Tank Specs. and Hoot Service and inspection Form
Page: 9 Management and Contingency Plan
Attachments: Soil and Site Evaluation Reports, Sample ATU Servicing Agreement and Hoot
Systems LLC Product Approval with maintenance requirements.
Mound Component Manual Used = Version 2.0 SBD-10691-P (N.01/01R. 10/12)
Pressure Distribution Component Manual Version 2.0 SBD-10706-P (N 01/01R. 10/12)
Designer. Keith E. Stoner,
Signature: "L)te'Z-6 2021
License # Designer 157-007
Phone # (715) 653-2324
Page 1 of 9
Plan Narrative
The following shared sanitary system design discussion focuses on the proposed 12 Bedroom/
1800 gallon per day sanitary system to serve Lots 18 thnr 209t the Rolling Hills Farm
Subdivision. This plan complies with the St. Croix County Land Use and Development
Ordinances. A "Conservation Development', Rolling Hills Farm is designed for 77 lots serviced
by 22 dispersal components located on common ground. Appropriate casements and
maintenance language were required prior to final approval.
The St. Croix County subdivision ordinance requires that each buildable lot has a soil and site
evaluation completed. For these 3 lots the mound dispersal area will be located just north of
Sanitary Easement Area 6 lying westerly of Lot 20 within the common area known as Outlot 1.
The soils in this area were tested to slide the proposed system north to create a greater separation
from the natural drainage area that moves surface water down the slope near the south property
line.
A four bedroom maximum design flow has been established for each lot. The county will require
a sanitary permit for each lot prior to construction for setting the septic/treatment components
verifying the design flow for each lot. These lots will be required to set an aerobic treatment tank
with built in trash capacity that will be connected to a 4" conveyance pipe that will gravity flow
to a common duplex dose tank located at the southwest corner of Lot 20, that will alternately
distribute the highly treated effluent to a common mound dispersal system consisting of a
8.0 ft. x 150 ft. mound dispersal cell.
Sanitary Site Plan
For: Rolling Hills Farm
Residential Property Owners Ass.
Outlot I in the SW114 andNW114
See. 29 T29N-RI7W
Town of Hammond - St. Croix County
1043 48'
i N
LB.O= g
ro 1040.4 VVF =
N 600 gpd \
• VEL
r
.o�F�
d (cL FN# 1622
`'a \ /
N — — — — C7
__—
S8801 s'o2 ^w
Proposed Pro
BM ELEV FN# 1619 ,WELL .
DW
6W 9P \/ FN# 1626
WELL
1 a �E3aa0
e a�Ae2 Pa _ q/9
1624 N / �gA399M
s
/ aa26
io. WE
1ag2
LOT tP
16 NW
LOT N �N
17 cN <
F
21 7 0IT
,
1036,01 FN# 1617 600 GPD
Proposec • veu 6 FGPD LOT
c 40 80 Typical of each lot will be a 4" Sch. 40 PVC Bldg Sewer DWF 18
and the placement of a Hoot H-600A Bio./Septic 600 GPD m 2, 7.1 m 21,7.1
Graphic Sc°Y (FYYt) N SO R LOT A SO IT
1 mch - 80 It.
1036.50' � 19 In
1035.0(
OUTLOT 1
29.56 ACRES Open Fallow Field Site
1,287,641 SQ. FT. 4
Proposed 6' x 150' Mound Dispersal Cell
located along the 1036.50' contour w/a S.E. of 1037 50'
n m \ 1037 00' rn LOT 4" PVC Bldg
20 Sewer
(Sch. 40 Typicap
zi rel N
N so 5v rn Proposed Hoot 0
a H-600A Blo /Septic i
GUBYAR➢
#2 Proposed 4" Sch 40 PVC Astm -D3034
gH'j Conveyance Pipe T Typical
/ Mound to °7Tarkw/SimtechSTF
Pro
Wieser Concrete W1250-MR Dose
-/100 In -line Filters
Serve Lots
H.W.L. 1027.7 18,19 + 20 Proposed Two 2" Sch.40 PVC F.M.
BM#1 —Top of Wooded Hub NW Corner of Easement #6
Cl Pt. # 2010 Eiev. = 103. 7.66'
2, 7e1
SO rT
TOO-
P
BM#2 = Top of Wooded Hub NW Corner of Easement #6 Existing Sanitary System for Lots 15-17
Contro Pt. # 2009 Elev. = 1033.90'
49 . 9' P/L
Page 3 of 9
Mound Plan View
L
Mound component Dimensions
A '
E
F
y
1I1
KL
MI41;',,
D
G
I 5.43'
W25.8
IL(Ih
(ft sit ) Dispersal ( ell Area
3Q5'J
l It Baal Area Available
1.00
I@Pd/o Linear Loading Rate
1 15.00
tt) I; 1) B Obs Pipe Placement
Mound Cross Section View
Aggregate Dispersal Area
Finished Grade 040.00 -0
F Elm
Dispersal
602
Shading Key
9 % Site Slope
Topsoil Cap
Subsoil Cap
By AS 1'M C33 Sand
® Tilled Layer
Aggregate
Obsem ation Pipe to be constructed of 4" diam.
Sch. 40 PVC pipe w/ water tight cap, a minimum
6" slot anchored with 3/8" rebar or a water closet
collar.
Fla
G �n
La 03x(ft)
Lateral
1036.50' (ft) Contour F levation
Detail of
T}pical Dispersal Cell
I A r
-
rxtile Fabric
Cover
Center Connection Duplex Manifold
Lateral Layout Diagram
t 75 fl. x
I' P
Note: F.M. attached to
center of the manifold.
S
5°i° -->
I urn -up ') ball valve or dean
'm plug
Number of Laterals
Lateral Diameter
Lateral Length (P)
Lateral Spacing (S)
Lateral Flow Rate
1 /2 Cell Flow Rate
System Flow Rate
total Dynamic Head
U
Duplex Force Main
-' per F NI-
1 1 /2
74 25'
4.00
15.12
30.24
60.48
25 ft.
Page 4 of 9
tt.
F P
Lateral, and force Main of Pyl Sch 40
per SPI able 384 30-�
9%
F-.75 ft. ..
x Holes equally spaced on
bottom of lateral
Note: Forceful coming into the center of cell, 1st
hole approx. 1.05' from the manifolds maintaining
the 2.75' hole spacing. Northwest manifold + F.M.
feed north lit of cell and same for the southwest
F.M. + manifold
in.
Orfice Diameter
ft.
Orifice Spacing (x)
ft
Orifices per Lateral
gpm
Orifice Density
gpm
Manifold Length
gPm
Manifold Diameter
ft
Forcemain Diameter
and Length
Lateral Turn -up Detail
5/32 or 0.156
in
2.75
ft.
28
10.71
112,
on]
4.00
ft.
1.5
in.
106' per F.M.
Finished Grade Threaded Cleanout Plug or Ball
6" to 8" diameter Laa"n Sprinkler Box Vahe
� V
Note: Lateral ends at last orifice where variable
length to cleanout begins.
/ Long Sweep 90 or Iwo 45` Bends Same
Diameter as Lateral
Distribution Lateral
Page 5 of 9
Duplex Pump DoseTank Component Cross Section
Approved Manhole Covers W ith Warning Labels
and Locking Device ' 4" Min. Above Final Grade
Weather Proof Junction Box
Electric per NEC 300 R SPS
4" Sch. 40 Vent
316 012 WAC
- or = to 12"
Above Final Grade
Disconnect
Note: SJE Rhombus Type 122Duplea
Alternate Outlet Location
(Demand Dose)
W;Approved 4" Sleeve
�!
Top of inlet = - 1032.00 (Set by Installer) Simtech STF /
Porce Main Diam. -
100 Filter —/
Weep Hole or Anti Siphon Device
Note: Pump switch and alarm to be A
Duplex Force Mains
wired to separate circuits.
B
p 1029 _3
Pump Off F,lev.
WLP1250_MR Gallon C
Duplex Pumps
Lank Mfr. Wiesert Concrete
D
Dose Tank Elev. ] 03850
Vertical Difference Between Pump Ott and Distribution Pipe = 8.6T
Minimum Required Supply Pressure ......................................
_
= 4.55
106' FT. of Force Main x 226 Friction Factor; I OOFT....
= 2.40'
Note: Maximum dose per Pressure Loss Through Filter ....._._..........
- 50'
_�._,
1.12 cell 180 gallons. Fatal D) namic Head ..................
16.12'
Min. dose per I r2 cell - 68.31 gals.
Number of Doses...- 5.74 Per Day Gal. Per Dati! ttof Doses = 156.77Gal. (Duplex
Volume of Backfloii ......._.............. ......................................
= 17.28 Gal.
Pumps.4lternating
Total Dose Volume..-_._...................._..................._......._......
174.05 Gal.
between 122 of
cell)
PumpPant. Ca acity 1-'53.16
p Gallons
Dimensions
Inches Gallons
Pump Tank Volune 34.81 Gal/Inch
�-
1
19 661.39
Note: Tank to have
B
2 69.62
two outlets.
Pumpr. Goulds
Mfr.
C
_
5 174.05
Note: Forcemains
Pump Model EP05
D
10 348.10
assumed to be equal
Minimum Discharge Rate = 30.24 GPM
per pump
in length.
Alarm Mfr. S.J.E. Rhombus Total -- 36.00 1253.16
Alarm Model Tank Alert
Bed Tank per SPS.383.45(5)
Anchor Tank as necessary to negate buoyant forces per SPS 383.43(8)(g).
Wastewater
Page 6 of 9
METERS, FEET
10 F-
Order
HP
Volts
Amps
Minimum
Circuit
Phase
Float
Switch
Cord
Discharg
Minimum
Minimum
Minimum
Maximum
Shipping
Number
Breaker
Style
Length
Connection
On Level
Off Level
Basin
Solids
Weight
Diameter
Size
Ibs.kg
EP0411
4
115
12
I
20
1
PluSwitch
No Switt ch
10
1 /`
Manual
Manual
15'
/."
20/91
EP0411A
Piggyback /
W,de-Angle
10,
12"
6"
21 / 9.5
-
EP0411F
PlugtU
No Swd
20'
Manual
Manual
20/91
EP0411 AC
Piggyback/
Wide -Angle
20'
12"
6"
21 / 9 5
EP0412
230
610
No lSwnch
10,
Manual
Manual
20 / 9.1
EP0412F
Plug/
No Switch
20'
Manual
Manual
20/9,1
EP0511 F
5
5
13
20
PS t
No Switch
20
Manual
Manual
i
22 • 10
EP0511 AC
Piggyback/
Wide -Angle
20'
12"
6•
231104
EP0512F
230
6 S
10
N Plug h
20
Manual
Manual
22 / 10
Single phase, duplex alternating pump control with override. Page 7 a+b of 9
The Model 122 control panel is designed to alternately control two 120, 208, or 240 VAC single phase pumps in water and sewage
installations- The alternating action equalizes pump wear In addition to the alternating pump control, this system provides override
control should either pump fail If an alarm condition occurs, an alarm switch activates the audiolvisual alarm system. Common
applications include pump chambers. sump pump basins, irrigation systems and lift stations
1. Enclosure measures 10 X 10 X 6 inches (25A X 25A X 15.24 cm)
Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized
thermoplastic with removable mounting feet for outdoor or indoor use)
Note: Options selected may increase enclosure size and change component
layout
2. Magnetic Motor Contactors control pumps by switching electrical lines
3. HOA Switches for manual pump control (mounted on circuit board).
4. Control Circuit Board provides pump control and alternation
5. Green pump Run Indicator Lights (mounted on circuit board)
6. Circuit Breakers (optional) provide pump disconnect and branch circuit
protection
7. Ground Lugs
8. Float Status Indicator Lights (mounted on circuit board)
9. Control and Alarm Power Indicator Lights (mounted on circuit board)
10. Auxiliary Alarm Contact, form C (mounted on circuit board)
NOTE: Schematic is located inside the panel on enclosure cover.
STANDARD ALARM PACKAGE
11. Red Alarm Beacon provides 360' visual check of alarm condition.
Note: NEMA 1 style utilizes a door mounted indicator in lieu of a beacon.
12. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel
rating).
Note: NEMA 1 style utilizes an internally mounted buzzer in lieu of horn
13. Exterior Alarm TestlNormallSilence Switch allows horn and light to be tested
and horn to be silenced in an alarm condition. Alarm automatically resets once
alarm condition is cleared.
14. Horn Silence Relay (mounted on circuit board)
NOTE: other options available.
Ar Entire control system (panel and switches) is UL Listed to meet and/or
exceed industry safety standards
Ar Dual safety certification for the United States and Canada
JW Standard package includes three 20' SJE SignalMaster' control
switches
■ Complete with step-by-step installation instructions
Five-year limited warranty
SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS.
SEE PRICE BOOK FOR LIST PRICE.
Model Shown 1221 W114X6A
COus
11.1370
Rh us
PO Box 1708, Detroit Lakes. MN 56502
1-888-DIAL-SJE • 1-218-847-1317
1-218-847-4617 Fax
email customer. service@sjerhombus com
www.sjerhombus.com
122 T FTTI C
MODEL 122
ALARM PACKAGE
= select options or no alarm package
t = alarm package (includes test/normal/silence switch, fuse red light, & hom)
ENCLOSURE RATING
= Indoor, NEMA 1 (metal)
E]OW = Weatherproof, NEMA 4X (engineered thermoplastic)
ERSTARTING DEVICE
1 = magnetic motor contactor 12012081240V
9 = magnetic motor contactor 120V only
PUMP FULL LOAD AMPS
= 0-7 FLA
1 = 7-15 FLA
2 = 15-20 FLA
3 = 20-30 FLA
PUMP DISCONNECTS
= no pump disconnect
4 = circuit breaker 120V (select STARTING DEVICE option 9 above)
120/208/240V (select STARTING DEVICE option 1 above)
FLOAT SWITCH APPLICATION
H or L = pump down or pump up (select 17 option)
X = no floats
OPTIONS Llsradbe/ow
ENCLOSURE UPSIZE - If you selected one or more of the * options, or two ** options,
a one-time enclosure upsize fee would apply
CODE OESCRIPTIaN
Q to Red beacon only / no audio
CODE
DESCRIPTION
(must select `0"for alarm package)
Q**
10K
Antl-condensation heater
0 1C
Hom only I no visual
Q
11C
NEMA 1 alarm panel
(must select "0'for alarm package)
11 D
NEMA 4X alarm panel
**3A
Alarm flasher
Q*
148
Main disconnect(rotary style mounted through door, non -Posed)
# 38
Manual alarm reset
(must select circuit breaker)
* 4A
Redundant off
*
0
0-20 FLA (total of both pumps)
(select Opton 4D if ffoats mduded)
*
20-60 FLA (total of both pumps)
Q 4B
Red redundantoff Indicator 8 alarm
Q
16A
10' cortl in lieu m20' (per flcat)
(must select Option 4A also)
16B
15' cord in heu of 20' (per float)
4D
Redundant off float
Q
16C
30' cord in lieu of 20' (perfloat)
(must selecr 4A optron) (select 17 option)
0
16D
40' cord in lieu of 20' (pertinat)
* 5A
Thermal cutout/heat sensor auto reset
17A
SJE SignalMastery f pipe damp 0 (per float)
(for pumps w/thermal switch leads)
Q
17B
SJE SlgnalMastera / externally weighted 0 (per float)
* 5E
Seal failure arcurt 8 red indicator (2 wire)
Q
17C
Sensor Float" / internally weighted ♦ (per float)
m 6A
Auxiliary alarm contad, torte C
0
17D
Sensor Float' / externally weighted ♦ (per float)
(included as standard)
0
17E
Sensor Float' Mini! pipe clamp A (per float)
Q * 8A
Elapsed time meter
Q
17F
Sensor Floatr Mini I externally weighted ♦ (per float)
Q * 8C
Event (cycle) counter
Q
17J
Sensor Float^ / pipe damp A (per float)
0 * 9_A
Pump overload
Q
19B
Lead lag selector switch
specify amperage after number 9 followed by letter "A"
0
19F
Fourth float to separate alarm function from lag
Example 912A = 12 amp pump
19T
TOA (Test/Off/Automatic) switches and pump run tights
* Q
0-25 FLA
through door mounted
*
25-30 FI A
0
19U
HOA (Hand/Off/Automabc) switches and pump run lights
10E
Lockable latch - NEMA 4X
through door mounted
t0E
Lockable latch - NEMA 1
Q
19X
Door mounted pump run indicator
* 1DF
Lightning arrestor (select pump cuuut breaker)
0 Mechanically -activated ♦ Mercury -activated
if addibmwi feRhw" are required, Celt the factory fora quote on an Engineered Custom control panel.
n w ■�r�•
r
. ^r,MODEL 122F17] W 9 0 T
Alarm Package
Enclosure Rating
Starting Device
Pump Full Load Amps
Pump Disconnect
Float Switch Application
Options: Auxiliary alarm contact, form C,
Elapsed time meter, event (cycle) counter,
SJE SigralMastee f pipe clamp
6A SAC 17A
bSJF-Rhrrnbus 0k14
Page 8 of 9
4" CAS -
a
INLET
0
n
u�
Im
31 }"
744"
"—
Iill _
41" 40"
TOP VIEW
SIDE VIEW
4" CAS
POLYLOK 12" ACCESS LID (TYP)
IZ SET RISER (TYP)
OUTLET
a
TANKS ARE MANUFACTURED TO MEET OR EXCEED ASTM C-1227 REQUIREMENTS
EK SCOM at'`. A!r ?,
4'^!
600 GPD GRAVITY DISCHARGE SYSTEM
H-600 A
H-600 A
TANK SPECIFICATIONS
DIMENSIONS:
WALL: 3"
BOTTOM: 3"
s
0
w
N
s
o
COVER: 4"
MANHOLE: 12" & 24" I.D. PLASTIC RISER
HEIGHT: 70" O.D.
o
LENGTH 106" O.D.
m
op
WIDTH: 74 1/2" O.D.
BELOW INLET: 57" O.D.
a
LIQUID LEVEL: 51"
W
WEIGHT 11,135 LBS.
n
W
INLET AND OUTLET:
4" CAST -A -SEAL (CAS) BOOT OR EQUAL
�' Y
C
COVER: MIX DESIGN M8 (NO FIBER)
C
TANK: MIX DESIGN #9 (SMALL FIBER)
z 00
� o
CUSTOMIZED TANKS:
`s N
FOR CUSTOM TANKS CONTACT WIESER CONCRETE
r->
W 2
m � O
W�00
0
a �
co ¢
o z
Z
m ¢
¢ U
o F
o D_
DRAWINGS SUBMITTED tO w
N
FOR APPROVAL =
APPROVED BY: SHEET NO
APPROVAL DATE:
PRODUCTS NEEDED BY: /OF 1
Page 8bof9
Hoot Service and Inspection Form
This testing and reporting shall be completed, signed and dated after each inspection. One
copy shall be retained by the maintenance company. The second copy is sent to the local
permitting authority and the third copy is sent to the system owner along with an invoice for
services by the maintenance company.
1 Actual Date of Visit-
2 System Inspection of Owner:
Address:
City, St., Zip:
Inspected Items:
Aerator .......... . ........ ........ .
Aeration Plumbing ................
Air Filter ...............................
Effluent Pump (if applicable).....
Chlorinator _....
OK System Light ....................
Alarm..................................
D-Box ........
Operational Inoperative Not Applicable
J
l
C1 I l
J
i J
Air Filter must be cleaned each service visit Operation of effluent disposal system must be made
each visit (if pumped). A system with greater than 70% Settleable Solids in the aeration chamber
must be pumped to avoid solids leaving the tank for the drainfield.
3. Repairs to system (list all components replaced):
4. Tests Required and Results:
Test
BOD (Grab)
TSS (Grab)
Fecal Coliform
Required Results Test Method
Signature of Inspector: Installer 11 or WW Lic #
Private Onsite Wastewater Treatment System Mound
Management Plan
Pursuant to SPS 383.54 Wis. Adm. Code each Private Onsite Wastewater Treatment
Svstem (POWTS) Shall Include information and procedures for maintaining the system
within the parameters of SPS 383 and 384, and the conditions of approN al by the
department. agent, or governmental unit. The approved plans and permits for the system
will be filed with the county zoning or health department.
This management plan complies with SPS 381.54. Wis Adm. Code. the Mound
Component Manual for Private Onsite Wastewater Treatment Systems (Version 2.0)
SBD-10691-P (N.OI/01) R. 10/12 and the Pressure Distribution Component Manual
(Version 2.0) SBD-10706-P (N 01-01) R. 10/12
Table 1: System Design Specifications
SanitaryPermit Number
Number of Bedrooms - -
12
Flow, (GPD)
1800
-Design
Soil Absorption Component Size (sic. 11.)
1200 (Pretreated Effluent)
Trash Tank Capacity Gal.
Pump Chamber Capacity Gal.
400 gal.
1250 gallons
_
_Type of Wastewater
Pretreated Domestic
_
Pre -Treatment Knit installed per structure
HOOT SYSTEMS H-600 A
Table 2: Soil Absorption Component— Limits of Reliable Operation
-
Septic Tank Component
Soil Absorption Component
Desien Flow -Peak (GPD)
600 per structure
1800
Max. Influent Particle size
NA
:51/8 Inch
Maximum BOD 5 (mgrl)
NA
<_ 30 m /1
g
Maximum TSS Imgil)
-
NA
--
< 30me� 1
-
Maximum FOG
NA ---
NA —
Table 3: Maintenance Schedule
Se tic Tani rtnspect and, or service once every 3 years
Dose "tank In- Line Filter Should inspect once a year and clean every 3 vears
Pump Chamber Inspect once every 3 years
Soil Absor tion Component Plush laterals every 18 months.
HOOT SYSTEMS II-600 A I Service every- 6 months for first 2 years. Then annually
j there after per maintenance agreement. See attached_
Page 9of'9a.b`r c
Septic Tank
The septic tank shall be maintained by an individual certified to service septic tanks under sec.
281_48, Stats. The contents of the septic tank shall be disposed of in accordance with NR 113,
Wis. Adm. Code (Servicing Septic or Holding Tanks. Pumping Chambers, Grease Interceptors,
Seepage Reds, Seepage Pits, Seepage Trenches, Privies, or Portable Restrooms).
The operating condition of the septic tank and outlet filter shall be assessed at least once every 3
years by inspection. The outlet filter shall be cleaned as necessary to ensure proper operation.
The filter cartridge should not be removed unless provisions are made to retain solids in the tank
that may slough off the filter when removed from its enclosure. If the filter is equipped with an
alarm, the filter shall be serviced if the alarm is activated continuously. Intermittent filter alanns
may indicate surge flows or an impending continuous alarm. The septic tank shall have its
contents removed when the volume of scum and sludge in the tank exceeds 1 /3 the liquid volume
of the tank. If the contents of the tank are not removed at the time of an assessment, maintenance
personnel shall advise the owner of when the nest service needs to be performed to maintain less
than maximum scum and sludge accumulation in the tank.
Pump Chamber
I he pump chamber also requires monitoring once even three years or the time of problem,
complaint or failure. Inspection should include checking the dose rate, volume and frequency.
Warning: The dose chamber may till due to flow continuing during pump malfunction or power
outages. One large dose when the power comes on or when the pump is repaired may cause the
dispersal system to have problems. In this situation, the pump chamber should be pumped by a
licensed pumper before pump cycling begins or other measures shall be used to dose the
component with only the proper amount of influent. This may include manual operation of the
pump controls until such time the pump chamber has reached its normal level.
Note: A Simtech STF-100 effluent filter will be installed in the dose tank for each
force main to provide the filtering of the effluent to the dispersal cell.
Septic tank and Pump chamber risers, access risers and covers should be inspected for water
tightness and soundness. Access openings used for service and assessment shall be sealed
watertight upon the completion of sery ice. Any opening deemed unsound, defective, or subject to
failure must be replaced. Exposed access openings greater than 8-inches in diameter shall be
secured by an effective locking device to prevent accidental or unauthorized entry to the tank
Warning: No one should enter a septic or other treatment or holding tank for any reason w ithout
being in full compliance with OSHA standards for entering a confined space. The atmosphere
within the septic or other treatment or holding tank may contain lethal gases, and rescue of a
person from the interior of the tank may he difficult or impossible.
I ank abandonment shall be accordance with SPS 383.33, Wis Adm. Code when the tank is no
longer used as a POWTS component.
Page 9 of 9 a, b + c
Soil Absorption Component
The soil absorption component serving this structure is designed to accept domestic wastewater
from a residential facility. The limits of operation of this component are shown in Table 2.
The longevity of a soil absorption component depends greatly on proper and timely maintenance,
and system use within or below the limits of reliable operation. Good water conservation
practices by all occupants and the installation of water conserving plumbing fixtures are key
factors in extending the useful life of this component.
The soil absorption component's operation must be assessed by inspection at least once every 3
years. Lateral turn ups are provided at the ends of the laterals for the purpose of flushing the lines
of any solids. Flushing these lines should be done every 18 months. 'The inspection shall include
recording levels of ponding, if any. in the observation pipes, and visual inspection for any
evidence of surface discharge from the component. On steeply sloping sites, areas of erosion
should he identified and reported to the owner for repair. The surface discharge of domestic
wastewater or sewage from the system is prohibited and considered a human health hazard.
Traffic around or over the soil absorption component should he avoided particularly during
winter months. The compaction or removal of snow cover over the component may lead to
hydraulic failure by freezing. This type of failure is usually temporap, but is difficult or
impossible to repair until weather conditions improve. In general, soil compaction over this
component will reduce diffusion of oxygen into the soil and dispersal cefl, which may lead to
more intense, and earlier. clogging of the soil.
Planting of deep rooted trees and shrubs directly over or within 10 feet of the component should
be avoided since root intrusion into the component may obstruct wastewater flow.
Contingency Plan
In the case of septic or dose tank component damage, measures shall he taken to repair or replace
the tanks to there original operating condition. Problems with the pretreatment unit should be
addressed to the POW 'fS Maintainer. Bi-annuall annual inspections should prevent any complete
failure. Should failure of the distribution cell component happen; the system shall be inspected to
determine the cause of -failure, effluent quality testing and wastewater flows. Steps taken to repair
or replace the dispersal cell may involve the removal of a bio-mat which would require cleaning
or replacement of the distribution network as well as replacing the aggregate system and clogged
portions of the sand fill.
Component Owners Contact List
Keith Knudtson Plumber/ATU Maintainer
St. Croix Countv Lon n
(651) 470-1737
(715) 386-4680
Wieser Concrete Products
_
Maiden Rock W1
(800) 336-3416
Septic Pumper
Powers Sanitation
(715) 249-5738
ROOT SYSTEMS LLC I1-600 A
(888) 878-4668
Page 9 of9 a, b + c
Wiscorm Department of Safety and Professional Services
aynsionaindustry S SOIL EVALUATION REPORT
in accordance with SPS 395, Wis. Adm. Code
#3637
Page 1 of 3
Keith Stoner CST
Attach complete site an on
p paper not less than 8'f x 11 inches in size. Plan must
County
Croix
include, but not limited to: vertical and horizontal reference point(BM), dirdirectionSt.
and
-- - - ----- -—_ _
percent slope, scale or dimensions, north arrow, and location and distance to nearest road.
Parcel I.D.
please print gill intonnatlon.
018-2019-78-000
--- — -- -- - -
Personal information you prwMe may he used for secondary f+urpases (Prnaq Law. s. / $.06 (t) (m))
Reviewed By Date
Property Owner
Property Location I'rt h - Sr YY- S t_''I I , t t� tiq r ; 4
R.H.F. Residential Property Owners Ass.
-- - -
Govt. Lot NEl/4, NW1/4, S29, T29N, R17W
ropeny nets Mailirg Address
3435-Labore Rd, Ste 150
- -
Lot # Block # Subd. Name or CSM#
18 - 20 Rolling Hills Farm Outlet 1
__
City State Zip Code Phone Number
❑ City ❑ Village ® Town Nearest Road
Vadnais Heights i MN 1 55110 1
Hammond I 75Th Ave
® New Construction Use: ® Residential / Number of bedrooms 1Code derived design flow rate 1800 GPD
-
❑ Replacement ❑ Public or commercial - Describe: _
Parent material Loess_over Bedrock Re_sidium
Flood plain elevation, if applicable NA_ ft.
_
General comments Easement 6 for Lots 18,19 * 20 - Propose a 8 x 150' mound dispersal cell located along the 1036.50 contour with a system
and recommendations: elevation = 1037.50'. Upsbpe mound contour staked onsite.
ITI Boring # ❑ Boring
-
® Pit Ground surface elev. 1035.1S ft. Depth to limiting factor >62 in. Soil Application Rate
Horizon Depth �,, Dominant Color Redox Description 1 Texture Structure Consislenoce Boundary i Roots ;_ GPDMf
i
in. Munsell Ou. Sz. Cont. Color Gr. Sz. Sh. •Ettst 'EXJ2
i JO-12 1 10YR3/2 ! - sit 2msbk t mvfr Cs 3f-m I 0.6 0.8
- -- -' - �-
---r
2 1 12-24 10YR3/4 ! I 2msbk mvfr 1 gs 2f m 0.6 0.8
-
3 /
- _ 24-32 10YR4 3 2msbk mfr gs if-m 0.4 0.6
-a --
---
4 32-46 10YR4/4 51 gsms11 If 0.6 10
- - - ----
-------T--------�_ -
I
5 46-62 ! 10YR6/4+5J8 - Is 1 Osg ! col -1 0.7 1.6
�I-
- -- -- - --- -1— - ----� -
#5 -Bedrock Resldium
Boring # ❑ Boring
Ground
Pit _ _
surface elev. 1034.2 ft. _ _ Soil Application Rate
- _ - Depth [o Ymrtirg factor 34 in.
Horizon
Depth Dominant Color Redox Description Texture
in. Munsell
Structure
i Gonsistenc
Boundary
Roots L - GPDHt�_
Ou. Sz. Cont. Color
Gr. Sz. Sh.
•Ettp1 •EM2
1_"-4-;- 0-13 10YR3/2 - t -- -- - sit_ : 2msbk mvfr c 3f-m l 0.6 ' 0.8
�mvfr -2f-m
2 13-24 10YR3/4 - I 2msbk gs{ 0.6 O S
- -- - - --- - -
3 24-34 10YR4 3 i
_ / - d 2msbk 1 mfr gs if-m 0.4 0.6
- - --
4- 3447; 10YR4/4 c2d5YR5/8-d 2msbk mfr 1 gs if 0.4 0.6
--_ - -T -- ---
5 1 47-65 j 10YR6/4+5/8 f2d5YR5/8 Is 0 col - 0.7 1,6
-----
- - ----li __
#5 - Bedrock Re lr
omen[ s i = nw5> su < 22u mg/L and TSS >30 < 150 mg/L ' Effl t # = BODs-
30 mg/L and TSS < 30 mg/L
<
CST Name (Please Print) Signature: CST Number
Keith Stoner_ _- -- u _ 224059
Address Keith Stoner CST Date Eva loon Conducted Telephone Number
23220 Wood Creek Rd Siren, W 154872 6/17/2021 715-566-0900
Sao -"M(11 con 3)
Property Owner R.H.F.RewlearoaiPropetty_---- Parcel IDIf 018-2019-78-ON Page 2 of-3
❑ Bonng
Boring R ® Pit Grouts surface elev. 3037.2?, (t. Depth to limiting factor - 60 in. Appication Rate
hbr¢on
Depth
Dominant Color
Redox Description
Texture Structure bonsistencel
Boundary
Roots
�- - G_PDift'
in.
Munsell
Qu. Sz. Cont. Color
i Gr. Sz. Sh. '
I
_
Efllf1 •Etftt2
1 �' 0-10 30YR3/2 sil I 2msbk mvfr CS 31-m 0.6 j 0.8
2 10-18 10YR3 4 0.8
i— 1 2msbkmvfr� gs 2f-m 0 6
- -I -
18-26 � 10YR43 Imfr gs I 1 0.4--0.6
3-
ssbk
- - - - --
4
q 26�8 7,SYR4/sl 2 f m2f 1
mvfr gs 0.6 1.0
-F -- --
5 48-60 ; 7.5YR4/4 - sr fs OsgI ml gs if 0.5 1.0
_ ,
6 60f8 T 10YR5/9 c2d5YR5 8 sci m mfr 0.0 0.0
I ' � I
❑ Boring
Boring # ElPit Ground surface elev. __- _ ft. Depth to limiting factor in.
- -----
Soil Application Rater
Horizon Depth Dominant Colo
Redox Description Texture Structure Consistence) Boundary Roots ! GPD/ tr
in. Mansell
Ou. Sz. Cont. Color Gr. Sz. Sh. -Effd'1 •Effi2 _ -
i I i
i
--+--i. -_ - -- i -------T
Bourg
❑
Boring A Pit Ground surface elev. _ - _ ft Depth to limiting factor in. Soil Appication Rate
Horizon
i
Depth Dominant Color Redox Description Texture Structure Consistence
in.
Boundary Roots
F
GP_D_!h=
Munsefl Qu. Sz. Cont. Color Gr- Sz. Sh. I
'EfNt1 •EffM2
I
I i
I
� I
I
Effluent tit = Boos> 30 < 220 mgfL and TSS >30 < 150 mg�L
Effluentrig = BODs < 30 mgfL and TSS < 30 mal
Can-93Wrc ralnll,il
KNU Sraer CST
H.W.L. 1036.6
Soil Test Site Plan
For: Rolling Hills Farm
j Residential Properly Owners Ass.
Outlot I in the SWI14 and NW114
Sec. 29 T29N-Rl7W
Town ofHannnond - St. Croix County
—__
S8W19'02" W
o' tbU= y�
r 104040bwr =\-
N 600 gptl
R4 1624
d WEL 36
FN* 1622
,38
(CC7 _ LOT
-' 17
FN# 1621 •
_P,M FLEV
'
FN# 1619 WELL'
OUTLOT
1036 01
1
FN# 1617
Proposed:WELL
`= ooGPo
29.56 ACRES
rDwF
—
1,287,641 SO, FT.
I600GPD_I,
It--
o Q eo
`� 1
N -"' LOT
Mound to
1036 50'
S
�` 19
Crapnm sccie (EeeU Serve Lots
1037, 00' N LOT
m
1 �<n a eo n 18,19 + 20
1035.00'
N 20
N
_ 7
w
n
v,
Open Fallow
Field Site
a
Elevation Data
B#1 = 1035.18'
B#2 = 1034.23'
B#3 = 1037.23'
Grade a Proposed Dose Tank =
1036.98'
' = Backhoe Pit
r
H.W.L. 1027.7
i
i
n
BM
1 5�o a
BM#1 = Top of Wooded Hub NW Corner of Easement #6
Control Pt. # 2010 Elev, = 103.7 66'
BM#2 = Top of Wooded Hub NW Corner of Easement #6
Contro Pt. # 2009 Elev, = 1033 90'
LOT
18111.1
8"1.1
SU =T
LOT N
16 Nw
Nrn L
N N� 1
Ne � Cn
N
O� 21191
to so rr
Nw
1e
0 FT
91 q4
NE
,00 p3
Existing Sanitary System for Lots 15-17
4R4 6/17/21
SSttoone'r�CST# 224059
P/L
AEROBIC TREATMENT UNIT (ATU)
SERVICING AGREEMENT
This agreement is made pursuant to SPS 383.21(2Hc) 0), Wis. Adm. Code
Property Owner(s)
(Attach copy of deed if necessary)
Model:
Sanitary Wastewater Aerobic Hoot Systems LLC
Treatment Unit Hoot H-600 A Recording Area
Return To St. Croix County Community Development Dept.
As an inducement to the County of St. Croix to issue a sanitary pernut for a POWTS equipped with an aerobic treatment unit on the above
described property, we agree to do the following:
1 The owner agrees to conform to all applicable requirements of Ch. SPS.3 83, Wis. Adm. Code mlating to aerobic treatment and the
maintenance requirements for the proposed POWTS (Private Gristle Wastewater Treatment System) technology.
2. The owner agrees to maintain a contract with a licensed POWTS Maintainer for the life of the system The POWTS Maintainer will
perform periodic inspections and maintenance as required by the manufacturer and the department including, but not limited to: the blower,
electrical controls, treatment unit operation and sludge depth. These inspections are to be scheduled every 6 months for the first two years
of operation and yearly thereafter.
3. The owner agrees to contact the POWTS Maintainer immediately upon any malfunction of the treatment unit and to maintain the unit so as
to not create a human health hazard as described in s. 254.59, Stars.
4. The owner recognizes that the county department or POWTS Maintainer may make periodic inspections of the components to complete
performance monitoring of the not.
5. The owner or the owner's agent agrees to report to the department or designated agent at the completion of each inspection, maintenance or
servicing event in a manner specified by the department or designated agent within 30 calendar days from the date of inspection,
maintenance or servicing.
6. This agreement will remain in effect only until the county office responsible for the regulation of private onsite wastewater treatment
systems certifies that the property is no longer served by the aerobic treatment uniL In addition, this agreement may be cancelled by
executing and recording said certification with reference to this agreement in such manner which will permit the existence of the
certification to be determined by reference to the property.
7. This agreement shall be binding upon the owner, the heirs of the owner, and assignees of the owner. The owner shall submit this agreement
to the Register of Deeds, and the agreement shall be recorded by the Register of Deeds in a manner, which will permit the existence of the
agreement to be determined by reference to the property when: the aerobic treatment unit is installed.
(Use BLACK Ink Only)
Ownet(s) Names(s) (Print) Notarized Owner(s) Signatum(s) Subscribed and sworn to before me on this date:
Notary Public (Prim)
Notary Public (Signature)
My commission expires:
Drafted By: Keith E Stoner 23220 Woad Creek PA Siren. Wf 54872
���cnhieit,y��
DIVISION OF INDUSTRY SERVICES
Plumbing Product Revew
P.O. Box 7302
Madison, Wisconsin 53701-2658
i
TTY: contact Through Relay
t
ers�,=5v
Govemor Scott Walker Laura Gutierrez, Secretary
May 10, 2018
HOOT SYSTEMS, LLC
RON SUCHECKI
2885 HWY 14E
MAKE CHARLES LA 70607
Re: Description:
SEWAGE TREATMENT APPARATUS
Manufacturer
HOOT SYSTEMS, LLC
Product Name:
(trans id 3097849) H-SERIES HOOT
Model Number(s):
H-500-A (MAX. DWF 600 GPD)
Product File No:
20180134
The specifications and/or plans for this plumbing product have been reviewed and determined to be in compliance
with chapters SPS 382 through 384, Wisconsin Administrative Code, and Chapters 145 and 160, Wisconsin
Statutes.
The Department hereby issues an approval based on the Wisconsin Statutes and the Wisconsin Administrative
Code. This approval is valid until the end of May 2023.
This approval supersedes the approval issued on March 12, 2013 under product file number 20120398
This approval is contingent upon compliance with the following stipulation(s):
• This tank must be designed to withstand the pressures to which it will be subjected.
• The manufacturer must keep at the manufacturing plant a set of plans and specifications bearing the
department's stamp of approval. The plans and specifications must be open to inspection by an authorized
representative of the department
• This product may not receive backwash discharge from a water softener. Water softener backwash
discharge must be discharged in another method acceptable to chs. SPS 382 and 383 (formerly Comm 82
and 83), Wis. Admin. Code.
• The maximum daily wastewater flow, which may discharge through this product, is 600 gallons per day.
• When this product receives wastewater from dwellings, it will produce an effluent quality with a maximum
monthly average value for BOD5 of less than or equal to 30 mg/L, TSS of less than or equal to 30 mg/L TSS
and F.O.G. of less than 30 mg/L and fecal coliform of less than or equal to 10,000 cfu/100ml.
• Plan review for the installation of this product must be obtained from the department in accordance with SPS
382.20 (1) of the Wis. Adm. Code.
• This product must have installed a department -approved effluent filter capable of filtering particles of 1/8
inch in size or larger.
SBD-10564-E (N.10,V7) File Ref. 18013403.DOC
ST. CRO NTY SANITARY SYSTEM File#:
/ nly
OWNERSHIP/ADDRESS FORM �z�e0 7
Community Development Department will utilize this information to provide the property owner with
information regarding operation and maintenance of your new or replacement sanitary system! This
information will be provided as part of our ongoing efforts to protect public health, your well, groundwater,
surface water, property values, and county resources. Once approved, this completed form and educational
information will be sent to you by email. If you would like to view your issued sanitary permit online, you can
do so by using the Property Files Scanned weblink.
OWNER/BUYER INFORM774
- `�L
owner/Buyer Rolling Hills Farm owners assoc. OCT 01
Mailing Address 3435 Labore Rd. mmt. crox
City/State/Zip Vadnais Heights Mn. 55110 eyes,
Phone Number (required) 651-248-1664
Email Address (required) W-1-v-e-to 7 q!n Pi b t a �.o , �f. ^ .5 . c o t",
Parcel Identification Number 018-2019-7
(found on the property tax bill)
NEW SYSTEM: LEGAL DESCRIPTION
Property Location SW t/4 , NW 1/4 , Sec. 29 T 29 N R 17 W, Town of Hammond
Subdivision Plat: Rolling Hills Farm
Q.rt+ Survey p # q I Volume ,
Vlfmranty Deed #'il / f 3S� 1�_(before 2006)Volume
Number of bedrooms 12
Lot # ) 21-2-0
Page At
Page #
Spec house N yes D no Lot lines identifiable ■ yes D no
OFFICE USE ONLY
New Property Address N/A -
(Verification 'new address required from Community Development Department for new constnxtion)
(Staff Initials) (Date)
This form must be submitted with all Private Onsite Water Treatment System (POWTS) applications.
New System: Include with this form a recorded warranty deed from the Register of Deeds Office and a copy of the certified
survey map if reference is made in the warranty deed.
Community Development Department - Land Use Division
715-386-4680 St. Croix County Government Center
cdd@sccwl.aov 1101 Carmichael Road, Hudson, WI 54016
715-245-4250 Fax
www.sccwraov
AJLD
Wisconsin. of Safety and 77ozim
L— O�'�'��� #13637
Division of SOilFVei IJAM lid REPORT
ORIGINAL
0I Page 1 of 3
II I I 'n . accordance with SPS 385, Wis. Adm. Code L ST a�do� I — 939 Keith Stoner CST
Attach mplete site plan on paper not le than 8Yz x 11 inches in size. Plan must
County
St. Croix
include, not I' itr�ljpkvetbP.9t And ho ' tal reference point (BM), dnrection and
Parcel I.D.
percent {�eo®�fr�i9@91tfltlfh row, and location and distance to nearest road.
018-2019-78 000
Please prfnt aH information.
R 13y Date
Personal information you provide may be used for secondary purposes (Privacy Law, s. 15.04 (1) (m)).
/C I
Property Owner
Property Location rr{vF Sc`fY- tk, I lU il4 - tJ y
R.H.F. Residential Property Owners Ass.
Govt. Lot + NE1/4, NW 1/4, S29, T29N, R17W
Property Owners Mailing Address -
Lot #
Block It
Subd. Name or CSM#
3435 Labore Rd, Ste 150
18 - 20
Rolling Hills Farm Outlet 1
City State Zip Code Phone Number
❑ City ❑ Village ® Town Nearest Road
Vadnais Heights MN 1 55110 1
Hammond I 75Th Ave
® New Construction Use: ® Residential / Number of bedrooms 12 Code derived design flow rate 1800 GPD
_
❑ Replacement ❑ Public or commercial - Describe:
Parent material Loess over Bedrock Residium _ Flood plain elevation, it applicable _ NA ft.
General comments Easement 6 for Lots 18,19 +20 - Propose a 8 x 150' mound dispersal cel located along the 1036.50 contour with a system
and recomme ations: elevafiDn =1037.50'. Upslope mound contour staked onsite.
" l IJ:c
19A+�.CLStxQ
❑ Boring 1 -2t9 r
❑
Bo rig #
® Pit Ground surface elev. 1035.1$ ft. Depth to limiting factor >62 in. Soil Application Rate
Horizon I Depth
Dominant Color
Redoz Description
Texture
Structure
Consistence
Boundary
Roots
GPD/W
•En#1
•EM2
in.
Munsell
Ou. Sz Cont Color
Gr. Sz. Sh.
1
0-12
10YR3/2
sit
2msbk
mvfr
C5
gs
3f-m
0.6
0.8
2
12-24
10YR3/4
I
2msbk
mvfr
2f-m
0.6
0.8
3
24-32
10YR4/3
d
2msbk
mfr
gs
if-m
0.4
0.6
4
32-46
10YR4/4
sl
2f-msbk
mvfr
gs
if
0.6
1.0
5
46-62
10YR6/4+5/8
Is
Osg
ml
0.7
1.6
#5 - Bedrock Residium
❑ Baring
Boring #
® Pit Ground surface elev. 1034.2; ft. Depth to limiting factor 34 n. Soil Application Rate
Horizon
Depth
Dominant Color
ledox Description
Texture
Structure
Consists
ry
Roots
GPD/ftx
in.
Munsell
Ou. Sz. Cont. Color
Gr. Sz. Sh.
_
- Etf#1 •EB82
1
0-13
10YR3/2
-
sit
2msbk
mvfr
cs
3f-m
0.6
0.8
2
13-24
10YR3/4
I
2msbk
mvfr
gs
2f-m
0.6
0.8
3
2+34
10YR4/3
d
t 2msbk
mfr
gs
gs
if-m
0.4
0.6
4
34-47
10YR4/4
c2d5YR5 8
d
2msbk
mfr
if
0.4
0.6
5
47 65
10YR6/4+5/8
f2d5YR5/8
Is
Osg
ml
0.7
1.6
- — - #5 Bedrock Residmm--
- Ltnuent #1 = BOD? 30 < 220 mgfL and TSS >30 < 150 mgnL ' Effl t = BOD5 s30 rng/L and TSS < 30 mg/L
CST Name (Please Print) Signature: - CST Number
Keith Stoner 224059
ro
Address Keith Stoner CST Date Ev uabon Conducted Telephone Number
23220 Wood Creek Rd Siren, W 154872 6/17/2021 715-566-09M
seo-uw kamnat
Property owner R.H.F. Residential Property Parcel ID # 018-2019-78-000 page __?_of 3
Boring # ❑ Boring
® PH Ground Surface elev. 1037.23 ft. Depth to limiting factor 60 in. Soil AppYcation Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Ou. Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/RT
'Ee#1
-Ef Q
1 Ar�)
0-10
10YR3/2
sil
2msbk
mvfr
mvfr
a
gs
3f-m
2f-m
0.6
0.6
0.8
0.8
2
10-18
10YR3/4
I
2msbk
3
18-26
26-48
10YR4/3
d
2msbk
mfr
gs
2f
0.4
0.6
4
7.5YR4/4
s1
2f-msbk
mvfr
gs
2f
0.6
1.0
5
48-60
7.5YR4/4
sr fs
Osg
ml
gs
if
0.5
1.0
6
6D-68
10YR5/4
c2d5YR5/8
sd
m
mfr
0.0
0.0
❑ Boring
Boring # ❑ Pit Ground surface elev. ft. Depth to limiting factor in. Sal Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Ou. Sz. Cont. Color
Texture
Structure
I Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/f 2
'Ell#1
'Ee82
❑ Boring
Boring # ❑ Pit Ground surface elev. _ ft. Depth to limiting factor in. Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
TRFeZdox Description
Ou. Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/FP
'EM#1
'Eff#2
Effluent #1 = BOD5> 30 < 220 mg/L and TSS >30 < 150 mg/L
c /) 101
Effluent 92 = BODS 5 30 mg/L and TSS < 30 mg/L
SBD,Vffi 4RWn I) KCMh Sbg Sr
0 40 80
Crpphm�
1 inch - 80 ft.
/ H.W.L. 1036.6
Soil Test Site Plan
For: Rolling Hills Farm
Residential Properly' Owners Ass.
Outlot I in the SWI14 and NW1/4
Sec. 29 T29N-R17W
Toxin of Hammond - St. Croix Count}'
8% -- _� --
o S88"9'02''W _--
-e LbU=
1040 40 yyF =
N 60(!, tl
.� FN# 7629
"B2 FL FN# 1622
/o.
�2c P�e. �A02
# 1621.
BM ELEV ' FN# 1619 . WELL DWF tl'
103601 FN# 1617 600 GPD
OUTLOT 1 WELL F
Proposed 6 0 GPD LOT
29.56 ACRES DwF 16
1,287,641 SQ. FT. 600 GPD m 21781 m z17W
N N, so I LOT g 50 FT
to
N•
Mound to 1036 50'
Serve Lots 1037 00' N LOT
N
16,19 t 20 035,00' N 20
u,
1F u v
O21781
Open Fallow Field Site so Fr
Elevation Data
B#1 = 1035.18'
B#2 = 1034.23'
B#3 = 1037.23'
Grade (& Proposed Dose Tank = 1036.98
' = Backhoe Ph
H.W.L. 1
9% 1
F. N
AA
BM
R Nl
BM#1 Top of Wooded Hub NW Corner of Easement #6
Control Pt. # 2010 Elev. = 103.7,66'
BM#2 = Top of Wooded Hub NW Corner of Easement #6
Centro Pt. # 2009 Elev. = 1033.90'
U
A3�
C16'L -' � g9���•
5 AAZg•`N '
6
6g2
VEL
LOT N
16
LOT
N�
.
17
wo
'1,7.1
50 FT
-" tJ
wc0
oo
o rr
0
rn
A3
,�pp
Existing Sanitary System for Lots 15-17
P/L
AQ
6111111 N
CST# 224059
L
1
ItVF
O�WNER[te oc xunxwF. Lw
E.a.E ROLLING HILLS FARM
xaoeox. vn e
LOCATED IN E OF NWI/4 OF THE SWI/4, THE NEIµ OF THE SWIM, FART OF INE SWI/O OF THE
CTH
SWIµ, MOSE114 NTOFTHESW TOWN
LIF SECTIOND. AND OM OF WE NE1/4 OF WE
SURVEVOgx � � NW1µ OF SECTION 32,ALL IN T28N, RIiW, TOWN OF HAMMOND, ST. CROIX COUNT', WIBCONBIN.
Hoxn:ur,oe Flsnl.'a.ixo. I r , LOTHEE91 �'� xw�,w• ., _ -
wa.nw.wlPePa.r. ! ,E I— sEE eTI
EoaaNre w ewaa e E I
LoraD
♦rnrr CeNStrtnnO.wo ��C� [ably 1 LOT 99 BEE 6NEC
_mn.ure5rm%axxu 1 1
xuoeora, vn was _._ $ IE 1 EL.. - r rmu,.w,,,. i'
' .� 1' 9fy . •y1 LOT LOi
1 • 1 ,1 J • \ 29 29
J Y I ODUTLOTT 2 )j d ,Ac-
9Ni
F5 LOT�.24 i .n
[� 16 i •' i 22 0 0.1�
MAICN YNE SEE SHEET I \ \ LOT
R
5 i
_ S i
Id:4
a
i
y 1CTv' A
I I
I i
LOYI
_ I
I'
ttVrl/Y6R
�II
` LOCATION SKETCH
-iE
T29N, R1TW
y� 22
0T \ n. '[\ x. 1LO
2T
2
tim
r, PL ` �,I � 6MTSH YxE 6[E 6NER •
OUROT 3 LOT
�! ,a.¢nn ` - f�__r• \ LOT
la EEc 6NFEr•
IS x
LOT"11p �[
r LOT 11T . Y
LOTl
5S LOT IS
OUTLCT I Il � :a fn 5 1 •: 1
�t
r$is S1, en
It 1 S
Nb9sTaew ,u1.Tr-
3li 1
�� uFw fkac Pg,p,y IF
. 0 1 tinrr,m, n.uw
i
• WY6.58'W b16.25
tr.tt. r,s: L'I. mt
i i'1� LEOENO
PRIMMVMLDINOSEOIACKUNE6
nx m. or TYPICAL �, o
nu.¢¢ncw ¢ .-,_�_._.___ � �..��•'SiL4 / :n,rrnr'uror
r.ues.�.rt,�iwe..r,�•w¢rntm � _1 •..� i T��. nw � .vw�
urrz w:.:.uwuuva^. r.-mnurwum n �
vma.n. • u, li 4 y!`NY. %i l� IS
rn. m.er+rreuo
slPnxwwirw xuuo.uo>.•eiunw uumex.xce nVAL: powNw.mEroNr.un_Em ��:wu am',urw.r,
rr. �e.ra.s w:arr[w ^-war.^Nw M_,.�Ws w r rmwq+n 1r� 6¢, lletlf,m se, Ir'ew30wW�If6I1(Ij o]rp}
-,e...._�.....,..-a...,.....�..e-.. .e.w:�w.�n. �•-•°-.�:a. w.,..`_" cM'wINYOYMv�//b�V���jl(�V[rZ➢�E'rtL s.,r.
„s,..,.e,.,.rrwa¢w,+n�rrr.waw�rrvwtl rura BCA411N FEET 1'-10a �rynn��o!
,�—�.Ea 6N bOFb SNEET6
12 teAm"y'? t)
ir-Nov, COUNTY NO. 633967
STATE SANITARY PERMIT
POLLING
OWNER nn-suAQ i
PLUMBE ff" T
TOWN OF -A ska
SEC _9T N,
AND/OR LO
S PERMIT
19
# ILLS ,:#Rw%
TIoN
c.# 648YY3
NO.
CHAPTER 145.1313 (2) NTSCONSIN STATUTES
(a) The purpose of the sanitary permit is to allow installation
of the private sewage system described in the permit.
(b) The approval of the sanitary permit is based on
regulations in force on the date of approval.
(c) The sanitary permit is valid and may be renewed for a
specified period.
(d) Changed regulations will not impair the validity of a
sanitary permit.
(e) Renewal of the sanitary permit will be based on
regulations in force at the time renewal is sought. and that
changed regulations may impede renewal.
The sanitary permit is transferable.
-story: 1977 c. 168; 1979 c. 34,221; 1981 c. 314
Note: If you wish to renew the permit, or transfer ownership of
the permit, please contact the county agthorlty.
4MMJ6- A�J� O ED ISSUING OFFICER - DATE
EXPIRES 1 UNLESS
RENEWED BEFORE THAT DATE
POST IN PLAIN VIEW
VISIBLE FROM THE ROAD FRONTING THE LOT DURING CONSTRUCTION
SBD-06499 (RI1/20)