HomeMy WebLinkAbout018-1020-30-000 LOT 11v l
Ni,� Si1LVALUATION REPORT #1681
Department of Commerce in accordance with Comm 85, Wis. Adm. Code Page 1 of - 3
Division of Safety and Buildings Steel's Soil Service, Inc.
Attach complete site plan on paper not less than 8'/2 x 11 inches in size. Plan must County St. Croix
include, but not limited to- vertical and horizontal reference point (BM), direction and
percent slope, scale or dimensions, north arrow, and location and distance to nearest road. Parcel I.D. �i/�—l� enrin
—�
Please print all information.
Reviewed By Date
Personal information you provide may be used for secondary purposes (Privacy Law, s. 15.04 (1) (m)).
Property Owner Property Location
Bast, Kernon Govt. Lot na SE1/4 NW1/4, S10, T29N, R17W
Property Owner's Mailing Address Lot # Block # Subd. Name or CSM#
948 Labarge Rd. 11 na Girard Creek Preserve
City State Zip Code Phone Number City ❑ Village ® Town Nearest Road
Hudson WI 54016 715-386-7775 Hammond i Cty Rd T
New Construction Use. ® Residential / Number of bedrooms 4 Code derived design flow rate 600 - GPD
Replacement ❑ Public or commercial - Describe: na
Parent material Till Plains of end moraines and ground moraines. Flood plain elevation, if applicable _ na ft.
General comments Mound design, system elevation 105.45ft based on contour line elevation 104.45ft.
and recommendations: -
I
5
1 Boring #
Ground surface elev. 101.95 ft. Depth to limiting factor 42 in. Soil
ICI - -- - - _ Application Rate
Horizon Depth
in.
Dominant Color
Munsell
Redox Description Texture
Qu. Sz. Cont. Color
Structure
Gr. Sz. Sh.
Consistence Boundary Roots - GPD/ft2
*Eff#1 *Eff#2
1 0-7
2 7-20
3 20-35
4 35-42
5 42-62
10yr3/2
none
none
none
none
c1d 7.5 r5 6
sl
2msbk
mfr
cs
gw
cs
cs
na
if
na
.6
.4
1.0
.6
10yr4/4
7.5yr4/4
5yr4/4
10yr4/4
Sd
2msbk
osg
mfr
Is
mvfr
mfi
mfi
na
.7
.2
1.6
sl
om
om
na
.6
sl
na
.2
.6
I ) 1 R^rinri 4+ 1-1
—v, 'y 11 Ground surface elev. 101.95 ft. Depth to limiting factor 30 �, in.
® -_ p 9 - Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2
1 0-9 10yr3/2 none I 2msbk mfr cs 1f .6 1.0
2 9-19 10yr4/4 none scl 2msbk mfr gw na .4 .6
3 19-30 7.5yr4/4 none sl om mfr gw na .2 .6
4 30-54 5yr4/4 f1f 7.5yr5/6 ' sc om mfi cs na .0 .0
5 54-96 10yr4/4 none grcos osg mvfr na na .7 1.6
Horizon # 5 is wet.
* Effluent #1 = BOD 5> 30 < 220 mg/L and TSS >30 < 150 mg/L * Effluent #2 = BOD5 < 30 mg/L and TSS < 30 mg/L
CST Name (Please Prints �Siat re: CST Number
David J. Steel L �/ - 248956
Address Steel's Soil Service, Date Evaluation Conducted Telephone Number
c.
994 200th St. Baldwin, WI 54002 5/2/2005 715-760-0347
SBD-8330 (K.07/00)
AV
Property Owner Bast, Kernon Parcel ID # Pending
3 Boring # F� Depth to limiting factor
N1 Ground surface elev. 1�4.G5 ft. , 26 In.
Page 2 of 3
Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Qu. Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/ft2
*Eff#1
*Eff#2
1
0-7
10yr3/2
none
sil
2msbk
mfr
cs
1f
.6
.8
2
7-13
10yr4/4
none
sicl
2msbk
mfr
cs
na
.4
.6
3
13-26
7.5yr4/4
none
sl
2msbk
mfr
cs
na
.6
1.0
4
26-60
5yr4/4
c1d 7.5yr5/6
sl/sc
om
mfi
na
na
.0
.0
Horizon 00nning in at 49".
Boring # 1:1
Depth to limiting factor
n Ground surface elev. ft. in Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Qu. Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/ft2
*Eff#1
*Eff#2
Boring # F-1 Depth to limiting factor
n Ground surface elev. ft. ' in Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Qu. Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/ft2
*Eff#1
*Eff#2
* Effluent #1 = BOD5> 30 < 220 mg/L and TSS >30 < 150 mg/L * Effluent #2 = BODS < 30 mg/L and TSS <30 mg/L
The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
need material in an alternate format, please contact the department at 608-266-3151 or TTY 608-264-8777.
SBD-8330 (R.07/00) Steel's Soil Service, Inc.
If
STEEL'S SOIL SERVICE INC. 3of3
David J. Steel Kennon Bast 994 200" St.
CST-POWTSM SEl/4,NW1/4,S10,T29N,R17W Baldwin, WI 54002
Lic. #248956 Town of Baldwin, St. Croix Co. Direct 715-760-0347
Lot, 11 Fax 715-684-3449
This soil evaluation was conducted to satisfy a zoning requirement, it may or may not be suitable for your use.
The location of this test may or may not be as shown, as permanent lot lines were not established at the
time the soil test was conducted.
i
Legend N
1„=40'
b �
1 ♦ =Benchmark Ele. 100.00 ft
r � � Top of 3/4" pvc pipe
• =Alt Benchmark Ele. 99.45 ft
❑ Top of 3/4" pvc pipe
/ =Borings
Boring Elevations
B1 = 101.95 ft
B2 = 101.95 ft
B3 = 104.65 ft
B4 = 0.00 ft
7-