HomeMy WebLinkAbout002-1009-70-000 (2)= SOIL EVALUATION REPORT `ST aOO�� r G� #140
a\=FS Deparpnentof a �r sjralServices 1) /\ Z I_ Page 1 of 3
Division of Safe�ilain 1 1 -i f 7 S 3 1� Northland Plumbing, Inc.
in acco' ance with Comm 85 Wig Adm Cod
R Attach com leteisite Ian on er not lass than 8 x 11 inc
P P vap
include, but not invited, toy verticaland.f)odnontat reference point (BM), direction and
percent slope, sbaleordimertsidns, notth'-aifbW,'Srid location and distance to nearest road.
Please print all information.
Personal infonnallon you provide may be used for secondary purposes Privacy Law, s 15 64 (i) (m)).
County
St. Croix
cel I.D. aN- o @ : bj -/Oe - 90 - b
L - 100 - - DOa
iewed D�at Z
/ 1
IV/
Property Owner
Thomas Kanten
Property Location
Govt. Lot SE1/4, NW1/4, S5, T29N, R16W
Property Owner's Mailing Address
1187 22Dth St
Lot #
15
Block #
Subd. Name or CSM# v�a � y,,5
City State Zip Code Phone Number
Baldwin I WI 1 54002 715-684-2613
City Village Z Town Nearest Road
Baldwin I County Rd DO
® New Construction Use: ® Residential / Number of bedrooms II V 3 Code derived design flow,(( rate 450 GPD
❑Replacement ❑Public orcommercial -Describe::5 OtoKd LOrn, Apel,Y'SI
Parent material Glacial Till Flood plain elevation, if applicable Z-0A.) F
General comments la 4 f- Me, V
and recommendations: Sv'
1
Boring # Boring
Ph Ground surface elev. 98.45 ft. Depth to limiting factor 64 in. Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Qu, Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/fr'
'EB#1
'EfW
1
0-13
10YR3/2
sil
m2abk
mvfr
cs
1f
.6
.8
2
13-26
10YR4/4
sil
m2abk
mvfr
a
if
.6
.8
3
26-43
10YR5/4
sl
mlabk
mvfr
cs
.4
4
43-51
10YR4/6
cos
Osg
mfi
CS
.5
.5
5
51-60
10YR5/6
fs
05g
mfi
cs
.5
1.0
6
60-64
10YR4/4
sc
mlabk
mfi
cs
0.0
0.0
�vL� �
vv'r..r�1.
�oY > e
wov !d
vc
dv '
2
® Boring
Boring #
L, Pit Ground surface elev. 97.71 ft. Depth to limiting factor 2 in. Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Qu, Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/ft'
'Efl#1
'E1W
1
0-13
10YR3/2
sil
m2abk
mvfr
CS
2f
.6
.8
2
13-17
10YR4/4
sl
m2abk
mvfr
cs
if
.6
1.0
3
17-26
10YR5/4
scl
m2abk
mfi
cs
.4
.6
4
26-28
10YR5/4
7.5YR6/8fld spots
scl
m2abk
mfi
gs
.4
.6
5
28-54
10YR5/4
scl
m1abk
mfi
gs
0.0
0.0
" Effluent #1 = BODS> 30 < 220 mg/L and TSS >30 < 150 mg/L ' Effluent #2 = SODS < 30 mg/L and TSS <30 mg/L
CST Name (Please Print) S' at CST Number
Michael J. Myers u ���i� 267985
Address Northland Plumbing, Inc. If Date Evaluation Conducted Telephone Number
2943 130th Ave Glenwood City, WI 54013 12/8/2020 715-265-4115
SBD4330 (R.i 1/11)
)6
Properly Owner Thomas Kasten _ _ Parcel ID # Page 2 of 3
3
❑ Boring
Boring # pit Ground surface elev. 9� �'' —ft. Depth to limiting factor 50 in. Soil Application Rate
Horizon Depth
in
Dominant Color
Munsell
Redox Description
Qu. Sz, Cont. Color
Texture
Structure
Gr. Sz. Sh. I
Consistence
Boundary
I
Roots
GPDM2
'En#1
•Eft#2
1
0-5
10YR3/2
sit
m2abk
mvfr
cs
2f
.6
.8
2
5-14
10YR4/4
SC
m2abk
mvfr
cs
1f
.2
.3
3
14-50
10YR5/4
Cos
Osg
mfi
a
5
.5
4
50-62
10YR5/4
7.5YR6/8fld sp
sc
mlabk
mfi
gs
0.0
0.0
rti�.t,n-fs
>
Sao l
- 1
do ;
❑ Boring
Boring # ❑ ph Ground surface elev. ft. Depth to limiting in. factor Soil Application Rate
Horizon
Depth Dominant Color
in. Mansell
Redox Description
Qu. Sz. Coot. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/ft'
'Eft#1
•Eff#2
i
I -
i
❑ Boring
Boring # pN Ground surface elev. ft. Depth to limiting factor in.
❑ Soil Application Rate
Horizon
Depth
in.
Dominant Color
Munsell
Redox Description
Qu. Sz. Cont. Color
Texture
Structure
Gr. Sz. Sh.
Consistence
Boundary
Roots
GPD/W
*Eff#t
•Eff#2
I
'
Effluent #1 = BODs> 30 < 220 mg/L and TSS >30 < 150 mg/L ' Effluent #2 = BODs < 30 mg/L and TSS < 30 mg/L
The Department of Safety and Professional Servicese is an equal opportunity service provider and employer. If you need assistance to
access services or need material in an alternate format, contact the department at 608-266-3151 or TTY through Relay.
SBn-8330T. IR)1/11) Northland Plumbing, Inc
CHECK BOX AS APPLICABLE.
CHECK BOX AS APRICABLE.
0✓
SOIL EVALUATION
scale: 4o 49
SYSTEM PAGE 2 OF
D
SITE MAP I
60
PLOT PLAN
PROJECT NAME:
102
DESIGN FLOW: GPD
(LD a
Thomas Kanten
Attach design flow calculations for commercial plans.
PROJECTADDRESS:
County Rd Dd, Baldwin, WI 54002
Pipe Material / ASTM Standard (Tables 384.303 & 3B4.30-5)
BM Symbol: �
100.0
BM Elevation: FT
N
S ltary Sewer. /
Face Mah: /
BM Descriptlon:
top gale. pipe SE o(B1
Slope GreMeM(%)
Sl Tested Area:
o Well
2 /o Symbol („applicable): p
1,61cete north by
amwbq ane
IMPORTANT:
Show ground elevation contours at sultable Intervals.
on the epmpelte Fie
7s"'Y`�fJ wr�r ss,T29f�;(C/4 u� c,df r5
��ao4Kw l w,S,,j, --
64-. er�attCw'_'"f
s►a.*r = loe.o' - -I+•p qs/v, P►P�
xM4,2o foo.W/' - n.ef
Si = 98 vs'
82. 97.1 V
a3= p7•'1P
ki l 4. ,
r —
F' L(c�
pad 2%
S +-
1�
w•p(csT u7485 ��
PjL-
63
— 97.77'
— — � s•�rs'
?lv
70