Loading...
HomeMy WebLinkAbout006-1067-45-000 4 0 °o o 0 69 M n c M 0. 0 e _ c I O C O c ~ N 0 Mi E 2` o Co 02 a o I -0 3 I o ~ T~ I c: 0 0 72 u c Z o {L C C _ O CL CO 0 0 w m O m cN p 0 I c Q -0 C M Z y co > 'I E Z ~ a m c°•) F- In o I 0 z w d Z 'd c z N H -2 Cl) • ~ L I 0 U Q z z O N Z n ~ d c I O N 04 C'7 to a _ a w c c 04 ' G O a = U) bip Z ~ ! 0 L o 2 o 0 o z •N R ~aaa a a~ ti J V y rn rn z° I w ao ao 0 E 0 0 IL N V m m ((~~~111 0 Q (n Q O f~yl) C c o N V Y 0 a c a w Cro H = 0 0 c N Cl) Ci ° c E co d y H c d 00 • O M fA co O Z(n :9 U1 I r ~ Cd V ~ y ! €a u 0. • c~ a d m E ` c c V t A v a 2 oU) t" c Parcel 006-1067-45-000 07/03/2006 03:28 PM PAGE 1 OF 1 Alt. Parcel 30.31.16.464C 006 - TOWN OF CYLON Current X', ST. CROIX COUNTY, WISCONSIN Creation Date Historical Date Map # Sales Area Application # Permit # Permit Type 00 0 Tax Address: Owner(s): O = Current Owner, C = Current Co-Owner O - SKRAMSTAD, KURT L & CARI L KURT L & CARI L SKRAMSTAD 1905 200TH ST NEW RICHMOND WI 54017 Districts: SC = School SP = Special Property Address(es): * = Primary Type Dist # Description ` 1905 200TH ST SC 3962 NEW RICHMOND SP 1700 WITC Legal Description: Acres: 6.550 Plat: 3297-CSM 12/3297 SEC 30 T31 N R16W SW SW FRL BEING LOT 1 Block/Condo Bldg: LOT 1 CSM 12/3297 784/03 Tract(s): (Sec-Twn-Rng 401/4 1601/4) 30-31N-16W Notes: Parcel History: Date Doc # Vol/Page Type 07/25/1997 1253/485 QC 07/25/1997 1253/458 QC 07/23/1997 784/03 2006 SUMMARY Bill Fair Market Value: Assessed with: 0 Valuations: Last Changed: 09/08/2004 Description Class Acres Land Improve Total State Reason RESIDENTIAL G1 6.550 30,000 183,000 213,000 NO Totals for 2006: General Property 6.550 30,000 183,000 213,000 Woodland 0.000 0 0 Totals for 2005: General Property 6.550 30,000 183,000 213,000 Woodland 0.000 0 0 Lottery Credit: Claim Count: 1 Certification Date: 04/17/2001 Batch 512 Specials: User Special Code Category Amount Special Assessments Special Charges Delinquent Charges Total 0.00 0.00 0.00 0410211995 03:27 414-548-8614 SAFETY BUILDINGS DIV PAGE 01 SAFETY i BUILDINGS DIVISION 401 Pilot CGUM SYRe C Waukehsa, WI 53188 Visconsin Department of Commerce Tommy G. Thompson, Gov+rnor Wiliam J. L%Coshsn, Setn9ftry FAX..COVER SHEET Date Seat: pages sent excluding coves: TO: Iva FAX # (h1 g 43 FAX # ( 414 ) $48-8614 VOICE # 4 to y I op SfleciaLl Instructions : SBD462A (R.091®) 04/02/1995 03:27 414-548-8614 SAFETY BUILDINGS DIV PAGE 02 SAFETY a BUIt.DINGS DIVISION 401 PMot Court, Suite C Waukesha, WI 53188 isconsin Tommy G. Thompson, Governor Department of Commerce WIIIIarn J. Mecoshen, Secretary July 28, 1997 401 Pilot Court, Suite C Waukesha NI 53188 BIRD, BYRON JR 896 68 AVE AMERY WI 54001 RE: PLAN $97-50992 FEE RECEIVED: 180.00 SKRAMSTAD, KURT SW,SW,30,31,16W TOWN OF CYLON COUNTY OF ST CROTX MOUND SYSTEM The Department has reviewed the above-referenced submittal. Conditional approval is hereby granted for the system plan submittal. All noted items must be corrected. The'.rev.iew and approval of the system is based on chapter 145, Wisconsin Statutes, and chapters Comm 83 and 84, Wisconsin Administrative Code, and is contingent upon compliance with any stipulations shown on the plans. This system has.not been reviewed for the code ` requirements set forth in chapter Comm 82 or in chapters ILHR 50-64, Wisconsin Administrative Code. This plan submittal approval will expire two years from the approval date, or if a sanitary permit' is obtained, plan approval will expire on the day the initial sanitary permit expires. The licensed plumber responsible for this installation shall keep one set of plans with the Department's stamp of approval at the construction site. The installer shall notify the appropriate inspector when inspections can be made. All permits required by the city, village; township or county shall be obtained prior to installation. Inquiries should be directed to me at the number listed below. Please refer to the plan number shown above- Si erely, Julia A. Lewis Private Sewage Plan Reviewer Section of Private Sewage (414) 548-8638 (M-Th) 6:00 AM--4-.30 P.M. 4803R/ 1 581>4524-WAX (A-12M) 04/02/1995 03:27 414-548-8614 SAFETY BUILDINGS DIV PAGE 03 ( ACO GF PLIMP CHAM5ER CROSS SECTION AraG ?EGFICAfIOK!5 VC UT CAP 4"C.z, \jEIJT PIPE APPROVED LOCKINIG WEATHERPROOF /yAMHOLE COVEF JWJCTI OW BOX wiio , 4&#10o ~ 25FRO"1 OOOF. F-TU. WI/JDOW UR FRESH I AIR In1TAKE I GRADE I 4° MI'J. I Grp Ib° /MIA1. COAJDUIT A1 , PROVIDE rNIt T SEAL :IMLET 14. In i . f A * o oKr ~p ~l~ I I ALARM ors `atoF~~ ~ a sF~ e~y ~ I w APPRO ~vER~FO i oti c JO I NT ELEV FT APPROVED PI ~'110 PUNP~ OFF 3' ONTO FticF D SOLID SOIL. [.OWCKETE CLOCK RISi:It EXIT PERAITfED OULy IF TALK MALJUFACT URGIt HAS SLICV4 APPROVAL SEPTIC f SPE.CIFLGATIDf~1 ~Qv~ DOSE TANKS P'\AUUF,aCT UR 1A) !~k s NuMbER OF DOSES: PER DAN ER: 1.--, T^WK SIZIC: 600 GALLOWS DOSE VOLUME (/Il Njw syS IAICLUDING 6ACICFLOW% ll~zo GALLON ALARM MA►7UFACTURCR: rS/A15 MODEL WUTABER: ni&k1 CAPACITIES. A _ IJCHES OR yL.w`-~' GAL~LDO SWITCH TSPC: , lg._.. B = INCHES OR -Q GA/LLO►.15 C m ~,-,-,-IUCHE5 OR a`'U r.1 LOUS PUMP MAIJUFACYURER: MOOEL IJUMDER: D a INCHES OR - GALLOWSI17 SWITCH ThIPE: ~~'"yl♦S:.cS 'r MOTE: PUMP AWD ALARM ARE TO SE MIWIMUr1 DISCHARGE RATE -GP INSTALLED OW SEPARATE CIR C'VED s..►'~ GV CC VERTICAL IDIFFJ:&ENCE OETWEEW PUMP OFF A1J0 DISTRIDUTIOW PIPE-..ESL-- FEET J UL + ~cUM WETWORK SUPPLY PRE~~SSSURE~. 2.5 FE XT + . FEET OF FORCE MAIN X ."r IF or<ti~I~ICT1o~ FACTOR- 7 FEET ETV ~ $LDG5. TOTAL D~WAMIC HEAD = M19 7 5 0 9 9 2 01- el IIJTEFtMAL DIME. SLOWS OF THAW L. CsTM --;wIDTH,LIQUID DEPTH DAT E LICENSE UUr1BER:`-' - 91CvIQE D' 04102/1995 03:27 414-548-8614 SAFETY BUILDINGS DIV PAGE 04 Page, Of Distribution Pipe Detail For A Lateral Network PVC Force Main PVC Distribution Pipe 0 P ~~1to rS FF Frv ~o PVC Manifold Pipe Cpl ~ O X Ftic~ 5 1 X * Last Hole Should Be Next To End Cap Y PTiF t. S S Ft. RECEIVED X Inches JUL 16 1997 Y ~Inthes S F'ETY & BLDG& Div. Signed: Age L Hole Diameter„ Inch License Number: 5 I~Z Inch(es) Lateral Diameter Date: Inches Manifold Diameter ''02 Force Main Diameter_~ Inches # Holes Per Pipe 1W-75099L Invert .Elevation Of Laterals &Ir6✓t• 04/0211995 03:27 414-548-8614 SAFETY BUILDINGS DIV PAGE 05 do 3 S w Data Non-Woven Filter Fabric 4" Observation Pipe Perforated Below Filter Fabric ~Dis~riDulion Pipc i ASTM C-33 Sand Ej Topcoll F T. Scope Bed of LForte Moin ~FIowrd Drain Rock Frorn Pump Layer D V CresS Seclion Of A Mound 'S slern Usin A Bed Fo'r The Absorplion Areo G,-r -0 p4~ ly A Ft . H o t~ l u~ ok 6 Ft. r ~ r ~4l~aFt.- `s`ccr J Ft. r'Q , eF~ K 2, ~2 Ft. w,' J F t . p d!'Obseryol ion Pipe a A 1 Force Moin W L From Pump c 3 o Distribution Bed Of %2~- 2 w I Pipe Drain Rock 75 9C9,+'2 „ 9 4 Observation Pipe Permonent Marker Pipe or Rods R EIV~D JUL 1 610 Pion View Of Mound Using 0 Bed For The Absorplion Areo L'Y PAGE OF 04/02/1995 03:27 414-548-8614 SAFETY BUILDINGS DIV PAGE 06 PLOT PLAN' PROJECT Kurt Skramstad 9 56'2 Round Lake Lane Osceola Wi 54020 SW 1 / 4 SW i /4 s 30 ff 7ADDR IR W TOWN Cylon COUNTY ST, CROIX ' 7/13/97 BEDROOM 3 MP1tS Shaun Bird 3532, ~C DATE CONVENTIONAL IN-GROUND PRESSURE CONVENTIONAL LIFT HOLDING TANK 1000 GallonsLI1T TANK SIZE DOSE TANK SIZE 800 Gallon MOUND ~ SEPTIC TANK SIZE - HOLDING 'T'ANK SIZE LOAD RATE 1.7 ABSORPTION AREA 375' BED SIZE s'X 47' BENCHMARK V.R-P. Base of 112" Rod Orange Rbbon ASSUME ELEVATION 100' 100.6 ❑ BOREHOLE (DWELL &H.R.P. SW Cornerof Propeny SYSTEM ELEVATION Scale - 1/4" 10' .q 4 Area 25' Be10W 's • , , System to Remain Undisturbed s tr 24b System to be Install d+o ¢ Along the 99.6 p cp 00' Slope B-3 Contour Line ❑ B-1 FZ ~',r B.M. Dose Tank to be 1 2 Provided with Approved Tanks to be Warning Label and Properly ST Lockdown Cover Bedded 4001 amge Pro 3 Bedroom Well to be Located House >25' from Tanks and >50' from Mound Driveway 9750992 Ilk State Hi way 46 RE e-r-inci JUL 1 6 1997 SAFETY & BLDGS. DIV.