HomeMy WebLinkAbout004-1022-95-000 (2)
NVIsc ltls, ORIGINAL
SOIL EVALU ON REPORT #2336
Department of Commerce in accordance with @n1 85, Wis. Adm. Code Page 1 of 3
Division of Safety and Buildings Certified Soil Testing, LLC
County
Attach complete site plan on paper not less than 8% x 11 inches in siXd'
St. Croix
include, but not limited to: vertical and horizontal reference point ( I parcel LD.
percent slope, scale or dimensions, north arrow, and location and dist r lot 2
Please prin all infi►U.v E D Revi ByDate
Personal information you provide may be us d for secondary purposes (Privacy (mp. 3 `
Property Owner AU G 0 3 2001 roperty Location
Ofstie Darin Govt. Lot NE1/4, SE1/4, S10, T28N, R15W
Property Owner's Mailing Address ST. CROIX COUNTY of # Block # Subd. Name or CSM#
2104 Pierce/St. Croix Road 2 Pond View Acres
City State Zip Code one um er ❑ City 0 Village ® Town Nearest Road
Baldwin WI 54002 715-684-3299 Cady 310Th St.
Z New Construction Use: ® Residential / Number of bedrooms 3 Code derived design flow rate 450 GPD
[_j Replacement ❑ Public or commercial - Describe:
Parent material loess over pitted till Flood plain elevation, if applicable NA ft.
General comments install 3.75'x 120' rock cell mound on 100.0 controur as upslope edge of rock w/ 2.5' sand fill w/
and recommendations: state/county approval for interpretive determination Z ~ ty
Boring
❑ Borin #
g ®pit Ground surface elev. 101.3 ft. Depth to limiting factor 0 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft'
in. Munsell Qu. Sz. Cont. Color Gr. Sz, Sh. "Eff#1 *Eff#2.
1 0-3 7.5YR 3/2 - sil 2 m gr mvfr gs 1f1m .6~ .8
2 3-8 7.5YR 3/2 - sil 2 f sbk mvfr cs 1m .6 .8
3 8-10 10YR 4/3 f1f 7.5YR 4/6 sil 1 f pi mvfr gs im .4 .6
4 10-17 10YR 4/3 f2d 7.5YR 4/6 sil 1 m sbk mvfr gs lm .4 .6
5 17-21 lOYR 4/4 cep 7.5YR 5/8,4/6 7.5YR 5/3 sil 2 m sbk dsh gs lm 6 8
6 21-29 7.5YR 4/4 c2d 7.5YR 5/8,5/3 sl 0 m dh gs lm .2 .6
7 29-39 7.5YR 4/4 c2p 7.5YR 5/8,5/3 scl 0 m dh - 1m 0 0
i
L-i Boring
Fia]Boring # Pit Ground surface elev. 101.3 ft. Depth to limiting factor 0 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft=
in. Munsell Qu. Sz. Cont. Color Gr, Sz. Sh. ?Eff#1 •Eff#2
lacks A+4'; presumptive limit is 0'; H4 sbk occasionally parts to 1 f pl; 1 m roots to 35"
Effluent #1 = BOD5> 30 < 220 mg/L and TSS 0 < 150 mg/L ent #2 = BOD 30 mglL and TSS < 30 mg/L
CST Name (Please Print) Sign tur : CST Number
Henry F. Grote VQ~~ 5-7 222774
Address Certified Soil Testing, LLC Date Evaluation Conducted Telephone Number
E. 4366 353rd Ave. Menomonie, WI 54751 10/3/2005 715-233-0398
SBD-8330 (R.01/00)
Property Owner Ofstie, Darin Parcel ID # lot 2 Page 2 of 3 ,
2 ~ Boring
Boring #
X, Pit Ground surface elev. 98.7 ft. Depth to limiting factor 0 in.
Soil Application Rat
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary `Roots ` GPD/ft2
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. 'Eff#1 •Eff#2
1 0-8 7.5YR 3/2 - A 2 f sbk mvfr gs lm .6 .8
2 8-11 7.5YR 3/2 - sil 1 f pl mvfr cs lm .4 .6
3 11-14 10YR 4/3 fif 7.5YR 4/6 sl 1 m sbk mvfr gw lm .4 .7
4 14-24 7.5YR 4/4 fif 7,5YR 4/6 sl 0 m ds gs lm .2 .6
5 24-30 7.5YR 4/4 c2d 7.5YR 5/8 sl 0 m dsh gs 1m .2 .6
i
6 30-45 7.5YR 4/4 c3p 7.5YR 5/8,5/3 scl 0 m dh - - 0 0
lacks A+4"; presumptive limit is 0"; H3 sbk occasionally parts to 1 f pl; 1 m roots to 30"
3 Boring
Boring # X Pit Ground surface elev. 98.8 ft. Depth to limiting factor 0 in.
Soil Application Rat
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
in. Munsell Qu. Sz. Cont. Cola Gr. Sz. Sh. •Effx1 'Eff#2
1 1 0-9.5 7.5YR 3/2 - sil 1 m abk mvfr cs 1m .4 .6
2 9.5-15 10YR 4/3 f1d 7.5YR 4/6 sil 1 m sbk mvfr
fif 7.5YR 5/3 gs lm .4 .6
3 15-20 10YR 4/4 f2d 7.5YR 4/6,5/3 sl i m sbk mvfr gs im .4 .7
4 20-32 10YR 4/4 c2p 7.5YR 4/6,5/3 Is 1 m sbk mvfr gs 1m ,7 1.6
I
5 32-45 10YR 6/2,6/3 c3p 7.5YR 5/8 sl 0 m mvfr - if .2 .6
i
I
lacks A+4"; presumptive limit is 0"; H2 sbk occasionally parts to 1 f pl; 1 f roots to 40"
4 Boring
Boring # x Pit Ground surface elev. 100.0 ft. Depth to limiting factor 0 in.
Soil Application Rat
Horizon Depth Dominant Color Redox Description Texture Structure Consistence `Boundary Roots GPD/ft2
in. . Munsell Qu. Sz. Cont. Cola Gr. Sz. Sh. 'Eff#1 'Eff#2
1 0-5 7.5YR 3/2 - A 2 f sbk mvfr gs im .6 .8
2 5-10 7.5YR 3/2 - sil 1 m sbk mvfr cs 1m .4 .6
c2d 7.5YR 4/6
3 10-15 10YR 5/3 10YR 6/2 sil 1 m pl mvfr gs 1m .4 .6
4 15-18 10YR 4/4 lOYR 6 6 c2p /2 4/6 sicl 0 m mvfr gs lm 0 ! 0
5 18-36 5YR 4/4 c3p 7.5YR 5/8,5/3 scl 0 m dh - 1m 0 0
I
lacks A+4"; presumptive limit is 0"; H2 sbk occasionally parts to 1 f pl; 1 m roots to 31"
` Effluent #1 = BOD5 > 30 < 220 mg/L and TSS >30 < 150 mg/L ' Effluent #2 = BOD5 < 30 mg/L and TSS < 30 mg/L
The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
need material in an alternate format, please contact the department at 608-266-3151 or TTY 608-264-8777.
SBD-8330 (R.07/00) Certified Soil Testing, LLC
• n~ o DO
J vI ~ i
(PC "r
'
-
s
Vi
1 f _ so \ ?
~ a r
j
.r
J
o
3
q I L~
r
o
r
.I ~
a
a ~
Safety and Buildings
• 4003 N KINNEY COULEE RD
commerce.Wl.gov RECEIVED LA CROSSE WI '54601-1831
TDD (6138) 264-8777
i sco n si n JUN 2 5 2007 cow wwwmmerce.wi.gov/sb/
Department of Commerce
ST. CROIX COUNTY Jim Doyle, Governor
Mary P. Burke, Secretary
March 10, 2006
CUST ID No. 222774 ATTN: POWTS Inspector
HENRY F GROTE ZONING OFFICE
CERTIFIED SOIL TESTING ST CROIX COUNTY SPIA
E4366 353RD AVE 1101 CARMICHAEL RD
MENOMONIE WI 54751 HUDSON WI 54016
CONDITIONAL APPROVAL
PLAN APPROVAL EXPIRES: 03/10/2008 Identification Numbers
Transaction ID No. 1240465
SITE: Darin Ofstie Site ID No. 709674
Town of Cady, St Croix County Please refer to both identification numbers,
NEIA, SETA, S10, T28N, R15W above, ul all correspondence with the agency,
Proposed Lots: 1-3, 5, 7, 8, and 25
FOR: Object Type: Soil Saturation Determination Regulated Object ID No.: 1062716
The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes
and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in
chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements.
The following conditions shall be met during construction or installation and prior to occupancy or use:
1. Approval is hereby granted pursuant to s. Comm 85.60(2), Wis. Adm. Code, to estimate the depth to seasonal soil
saturation based on an interpretive determination process. Approval of the interpretive determination negates the
requirement in s. Comm 85.30(2)(b), Wis. Adm. Code to designate the ground surface as the highest level of soil
saturation when redoximorphic features are less than 4 inches below the bottom of the A horizon.
2. The estimated highest level of prolonged soil saturation approved under this determination is 6 inches below
grade. At least 30 inches of sand lift on top of 6 inches of unsaturated, in-situ soil is required for adequate treatment.
and dispersal.
3. The basal soil application rate for the mound shall be 0.2 gpd/sf, and the linear loading rate 53.5 gpd/ft for lots 1,
2, 5, 7, and 8, and 54.0 gpd/ft for lots 3 and 25.
4. Note that lot 7 has a restricted area for mound installation and is limited to a 2-bedroom home (300 gpd design
flow).
5. Chisel plowing to a depth of 16 inches immediately prior to sand placement is required to improve vertical water
movement into the soil solum.
6. Landscaping up slope of the mound shall be incorporated into the POWTS design to prevent surface water from
concentrating along the up slope edge of the mound and to divert surface water drainage away from the system. See
comments by the Certified Soil Tester regarding landscaping requirements for each lot.
7. This approval shall remain valid unless the site is altered in such a way that the depth to soil saturation would
change or if saturated conditions are observed for seven consecutive days at depths less than 3 feet below the
infiltrative surface of the POWTS distribution component.
8. This approval in no way relinquishes the use of color patterns to estimate the depth to high groundwater on any
other parcels or portions of parcels.
9. A copy of this approval letter and attachments must accompany the mound system design for this site for purposes
of plan approval and sanitary permit issuance.
10. Even though lots 4, 27, and 28 are discussed in the attached report, they have not been approved for a POWTS.