HomeMy WebLinkAbout014-1080-05-000
ORIGI MAt: 1812
Wisconsin Department of Commerce SOIL EVALUATION REPORT Page 1 of 3
Division of Safety and Buildings in accordance with Comm 85, Wis. Adm. Code Certified Soil Testing
Attach complete site plan on paper not less than 8'/= x 11 inches in size. Plan mus County
t
include, but not limited to: vertical and horizontal reference point (BM), direction ar et
percent slope, scale or dimensions, north arrow, and location and distance to near s~i6WD Parcel I.D.
CSM Pending
Please print all information. Reviewed By Date
Personal information you provide may)tfe used for secondary purposes48dvacyl.- s. 15.04 (1) (m)).
Property Owner Property Location
Seidling, Bernard Govt. Lot NW 1/4 NE 1/4 S 9 T 31 N R 15 W
Property Owner's Mailing Address r L Blo k Subd. Name or CSM#
Box 3006 10 A. CSM Pending
o-~ P, )
City Stale Zip Code Phone Number j Cit V' e Town Nearest Road
Eau Claire W1 54702 800-386-7 230Th Ave.
New Construction Use: ✓i Residential / Number of bedrooms 3 Code derived design flow rate 450 GPD
Replacement Public or commercial - Describe:
Parent material loess over till Flood plain elevation, if applicable NA
General comments
and recommendations: install 4' x 120' rock cell mound on 100.0 contour as upslope edge of rock w/ 25 sand fill w/ state/county
approval for interpretive site determination
Boring # , Boring
Pit Ground Surface elev. NA ft. Depth to limiting factor 0 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft'
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2
1 0-7 7.5YR 3/2 - sil 2 m gr mvfr cs 1f/m .5 .8
2 7-10 7.5YR 3/2 c1d 7.5YR 4/6 sil 2 m pl mvfr cs if 0 0
3 10-18 10YR 5/2 c2p 7.5YR 4/6 sicl 2 f-m sbk mvfr gs 1 m .4 .6
4 18-30 10YR 5/2 c3p 7.5YR 4/6,5/3 sicl 0 m mvfr - 0 0
I
lacks A+4": presumptive limit is 0"; horizon 2 has reticulated, decayed roots/organic matter; avoid this area
Boring
❑ Boring #
Pit Ground Surface elev. 100.0 ft. Depth to limiting factor 0 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft=
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2
1 0-5 7.5YR 3/2 - sil 2 m gr mvfr cs 1f/m .5 .8
2 5-11 7.5YR 3/2 - sil 2 f sbk mvfr cs 1f/m .5 8
3 111-14 1CYR 4/3 c2d 7.5YR 4/6 sil 2 f sbk mvfr cs 1m .5 .8
4 14-20 5YR 4/4 f2d 7.5YR 5/8,5/3 sl 2 f-m sbk mvfr - if .3 .5
i
lacks A+4": presumptive limit is 0"
* Effluent #1 = BOD5 > 30 < 220 mg/L and TSS >30 < 150 mg/L ffluent #2 = BOP <30 mg/L and TSS < 30 mgY-
CST Name (Please Print) Signat re CST Number
Henry F. Grote 222774
Address Certified Soil Testing Date Evaluation Conducted Telephone Number
E. 4366 353rd Ave., Menomonie, WI 54751 7/11/2003 715-233-0398
Property Owner Seidling, Bernard Parcel ID # CSM Pending Page 2 of 3
F3 ] Boring # Boring
✓n Pit Ground Surface elev. 99.8 ft. Depth to limiting factor 0 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description , Texture Structure Consistence Boundary Roots QPD/ 2
in. Munsell Qu. Sz. Cont. Color ` Gr. Sz. Sh. 'Eff#1 'Eff#2
1 0-5 7.5YR 3/2 - sil 2 m gr mvfr gs 1f/m .5 .8
2 5-10 7.5YR 3/2 _ sil 2 f sbk mvfr cs 1 m .5 .8
3 10-18 10YR 5/4 l f2d 7.OYR 6 6 /2 4/6 sil 2 f-m sbk mvfr gs 1 m .5 .8
4 18-24 10YR 5/4 c3p 7.5YR 5/8 SO 1 m abk mvfr cw if .2 .3
10YR 6/2
5 24-36 5YR 4/4 f2d 7.5YR 5/3 sl 0 m mfr - - .3 .5
lacks A+4": presumptive limit is 0"
❑ Boring # 1 Boring
~ j Pit Ground Surface elev. 99.7 ft. Depth to limiting factor 0 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft'
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. 'Eff#1 'Eff#2
1 0-5 7.5YR 3/2 - sil 2 m gr mvfr gs 1f/m 5 .8
2 5-11 7.5YR 3/2 - sil 2 f sbk mvfr cs inn .5 .8
3 11-18 10YR 5/4 f1f 7.5YR 4/6 sil 2 f-m sbk mvfr cs 1m .5 .8
4 18-28 7.5YR 4/4 f2d 7.5YR 5/8,5/3 sl 0 m mvfr - .3 .5
lacks A+4": presumptive limit is 0"
❑ Boring # Boring
Pit Ground Surface elev. ft. Depth to limiting factor in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots P / '
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 'Eff#2
i
~ I
I
~ I
` Effluent #1 = BOD5> 30 < 220 mg/L and TSS >30 < 150 mg/L * Effluent #2 = BOD5 < 30 mg/L and TSS < 30 mg/L
The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
need material in an alternate format, please contact the department at 608-266-3151 or TTY 608-264-8777.
SBD-8330 (R.07/00) Certified Soil Testing
9
~ d
N r
N b s
r' ^ tY
J
.S
o
4
i-
~ s
ID kA n
J j~ 3 J X
3 o-
~
CV,
/ N
t O N
~ v
.r S 1
o r^ r.
nn~l Y~ 5(
O
CIO
10
o
Ci
3
a C
1`o .0
--f rr
M F
J N
Parcel 014-1080-05-000 02/13/2008 11:25 AM
PAGE 1 OF 1
Alt. Parcel 09.31.15.595 014 - TOWN OF FOREST
Current X ST. CROIX COUNTY, WISCONSIN
Creation Date Historical Date Map # Sales Area Application # Permit # Permit Type
01/17/2006 00 0
Tax Address: Owner(s): O = Current Owner, C = Current Co-Owner
O - NOEL-WHITMAN, KATRINA
KATRINA NOEL-WHITMAN
132 N INDIES DR
MARATHON FL 33050
Districts: SC = School SP = Special Property Address(es): * = Primary
Type Dist # Description * 2865 230TH AVE
SC 1127 CLEAR LAKE
SP 8020 UPPER WILLOW REHAB DIST
SP 1700 WITC
Legal Description: Acres: 9.710 Plat: 10-094-FOREST ESTATES 014-06
SEC 9 T31 N R1 5W PT NW NE BEING FOREST Block/Condo Bldg: LOT 05
ESTATES LOT 5 (9.710AC)
Tract(s): (Sec-Twn-Rng 401/4 1601/4)
09-31N-15W NW NE
Parcel Histo :
Notes: History: Doc # Vol/Page Type
09/13/2006 834389 ALC
09/05/2006 833724 LC
01/17/2006 816565 10/0094 PLAT
08/23/2005 804284 20/5048 CSM
more...
2008 SUMMARY Bill Fair Market Value: Assessed with:
Use Value Assessment
Valuations: Last Changed: 05/16/2007
Description Class Acres Land Improve Total State Reason
AGRICULTURAL G4 9.700 1,500 0 1,500 NO
Totals for 2008:
General Property 9.700 1,500 0 1,500
Woodland 0.000 0 0
Totals for 2007:
General Property 9.700 1,500 0 1,500
Woodland 0.000 0 0
Lottery Credit: Claim Count: 0 Certification Date: Batch
Specials:
User Special Code Category Amount
Special Assessments Special Charges Delinquent Charges
Total 0.00 0.00 0.00
Parcel 014-1020-20-200 11/29/2005 01:09 PM
PAGE 1 OF 1
Alt. Parcel 9.31.15.1308 014 - TOWN OF FOREST
Current X ST. CROIX COUNTY, WISCONSIN
Creation Date Historical Date Map # Sales Area Application # Permit # Permit Type
00 0
Tax Address: Owner(s): O = Current Owner, C = Current Co-Owner
O - FOUR STAR PROPERTIES INC
FOUR STAR PROPERTIES INC
PO BOX 3006
EAU CLAIRE WI 54702
Districts: SC = School SP = Special Property Address(es): * = Primary
Type Dist # Description ` 2865 230TH AVE
SC 1127 CLEAR LAKE
SP 1700 WITC
Legal Description: Acres: 10.000 Plat: 4610-CSM 17-4610 014/03
SEC 9 T31 N R1 5W PT NW NE CSM 17-4610 LOT Block/Condo Bldg: LOT 02
2 (10.000AC) Tract(s): (Sec-Twn-Rng 40 1/4 160 1/4)
lbw 09-31N-15W NW NE
Iv
Notes: Parcel History:
Date Doc # Vol/Page Type
09/21/2005 807053 2893/146 QC
04/29/2004 761025 2560/165 AFF
10/15/2003 743758 2436/264 WD
09/12/2003 739879 17/4610 CPSM
ore..
2005 SUMMARY Bill M Fair Market Value: Assessed with:
Use Value Assessment
Valuations: Last Changed: 10/17/2005
Description Class Acres Land Improve Total State Reason
AGRICULTURAL G4 10.000 1,500 0 1,500 NO
i
Totals for 2005:
General Property 10.000 1,500 0 1,500
Woodland 0.000 0 0
Totals for 2004:
General Property 10.000 1,000 0 1,000
Woodland 0.000 0 0
Lottery Credit: Claim Count: 0 Certification Date: Batch M
Specials:
User Special Code Category Amount
Special Assessments Special Charges Delinquent Charges
Total 0.00 0.00 0.00
SAFETY AND BUILDINGS DIVISION
Integrated Services Bureau
13 East Spruce Street
INSPECTION REPORT Chippewa Falls, WI 54729
726
visconsin www.commerce.state.wi.us/sb
(715) 726-2544
544
Department of Commerce
Date of Inspection: July 25, 2003 Plumber Name and Address:
Project Name: Seidling NA
Use: New Residential
Legal Description: NW, N ,
Site Number: Certified Soil Tester Name and Address:
Subdivision: Lot 2 Reg M f~/LPcaI b Henry F. Grote, CST 222774
Municipality: Town of Forest E4366 353rd Ave
County: St. Croix Menomonie, WI 54751
Plan Transaction Number: NA, Owner Name and Address:
Sanitary Permit Number: NA Bernard Seidling
PO Box 3006
Wastewater Flow: 450 d s Eau Claire, WI 54702-3006
Persons Present: H. Grote, (800) 386-7969
An onsite soils verification was conducted at the above referenced site as per district policy for all sites with less
than four inches of unsaturated soil below the bottom of the A horizon. The intent of this investigation is to
confirm initial observations by the certified soil tester (CST) relating to the presence or absence of redoximorphic
features in the A horizon and subsoil. In-situ soil texture, structure, and consistence factors were also reviewed
as they relate to wastewater application rates. Other site conditions such as percent and direction of slope,
landscape position, land surface contour length, and surface water hydrology may also be noted and their effects
are factors considered in the recommendations and conclusions portion of this report.
A typical soil profile could be described as follows:
T-1 00-05" 10YR 3/3 sit, 2mgr, mfr, cw.
05-10" 10YR 3/3 sil, 2msbk parting to 2mpl, mfr, cw.
10-16" 10YR 4/4 sil, 2mpl, mfr, aw w/f1f 10YR 4/6 rmfs.
16-20" 5YR 4/4 scl, 2msbk, mfr, w/ c2d 7.5YR 5/6 & 5/3 rmfs.
Recommendations for this site include the possible use of a mound system designed to overcome limitations of a
high level of seasonal soil saturation and slow permeability present in the subsoil. A soil saturation determination
pursuant to Comm 85.60 must be completed by a CST and approved by the department to certify that this site
has at least 6 inches of soil free of saturated conditions for seven or more consecutive days.
Should a mound design be pursued for use at this site, the linear loading rate should not exceed 4.5 gpd/ft and
the basal wastewater application rated should not exceed 0.3 gpd/ft2 (even if the platy structure is plowed to
realign it to blocky structure). At least 26 inches of sand lift must be used when applying septic tank effluent to
the distribution cell. The longest portion of the mound must be orientated along the contour.
The mound shall be constructed to divert surface water around the up slope mound toe as much as possible. An
up slope surface water diversion is recommended to divert surface and shallow subsurface water away from the
mound area.
If there are any questions regarding this report, please contact me.
roy G. ans cy, stewater pecialist
Ljansky commerce.state.wi E-mail
715/726-2544 Voice 715/726-2549 Fax
cc: [RCounty ❑ Plumber 0 CST ❑ Owner ❑ Other