HomeMy WebLinkAbout018-2007-08-000 Safety and Buildings 13 E SPRUCE STREET commerceml.gov CHIPPEWA FALLS WI 54729 TDD (608) 264-8777 sin www.commerce.wi.gov/sb/ www.wisconsin.gov iscon, Department of Commerce Jim Doyle, Governor Mary P. Burke, Secretary December 02, 2005 CUST ID No. 226900 4TTN. POWTS Inspector SHAUN R BIRD ZONING OFFICE BIRD PLUMBING, INC ST CROIX COUNTY SPIA 1008 192 ND AVE 1101 CARMICHAEL RD NEW RICHMOND WI 54017 HUDSON WI 54016 CONDITIONAL APPROVAL Identification Numbers PLAN APPROVAL EXPIRES: NA Transaction ID No. 1079361 Site ID No. 692132 SITE: PC Collova Builders Please refer to both identification numbers, Town of Hammond, St Croix County S5, T29N, R17W above, in allcorrespondence with the agency. 1/4 Lot: 8 Tubdiv'ision: Farmview Ridge Subd FOR: Object Type: Soil Saturation Determination Regulated Object ID No.: 991436 The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. The following conditions shall be met during construction or installation and prior to occupancy or use: 1. Approval is hereby granted pursuant to s. Comm 85.60(2), Wis. Adm. Code, to estimate the depth to seasonal soil saturation based on an interpretive determination process. Approval of the interpretive determination negates the requirement in s. Comm 85.30(2)(b), Wis. Adm. Code to designate the ground surface as the highest level of soil saturation when redoximorphic features are less than 4 inches below the bottom of the A horizon. 2. The estimated highest level of prolonged soil saturation approved under this determination is 6 inches below grade. At least 30 inches of sand lift on top of 6 inches of unsaturated, in-situ soil is required for adequate treatment and dispersal. 3. The basal soil application rate for the mound shall be 0.20 gpd/sf, and the linear loading rate 4.5 gpd/ft. 4. Chisel plowing to a depth of 12-16 inches immediately prior to sand placement is required to improve vertical water movement into the soil solum. 5. Landscaping up slope of the mound shall be incorporated into the POWTS design (see recommendation by CST) to prevent surface water from concentrating along the up slope edge of the mound and to divert surface water drainage away from the system. 6. This approval shall remain valid unless the site is altered in such a way that the depth to soil saturation would change or if saturated conditions are observed for seven consecutive days at depths less than 3 feet below the infiltrative surface of the POWTS distribution component. 7. This approval in no way relinquishes the use of color patterns to estimate the depth to high groundwater on any other parcels or portions of parcels. 8. A copy of this approval letter and attachments must accompany the mound system design for this site for purposes of plan approval and sanitary permit issuance. If the Interpretive Determination Report was accompanied with a plan and an expiration date is shown on this letter, the expiration date only applies to the plans for the design, not to the decision on the Interpretive Determination Report. r SHAUN R BIRD Page 2 12/2/2005 A copy of the approved plans, specifications and this letter shall be on-site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. If plan index sheets were submitted jn lieu of additional full plan sets, a copy of this approval letter and index sheet shall be attached to plans that correspond with the copy on file with the Department. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/installation/operation. If this construction project will disturb one or more acres of land, an Erosion Control Notice of Intent (NOI) shall be filed with the department 14 days prior to any earth disturbing activities. In granting this approval the Division of Safety & Buildings reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sincerely, Fee Required $ 100.00 Fee Received $ 100.00 Balance Due $ 0.00 Leroy iG.isky, P , Wastew er Specialist Integrated Services Bureau WiSMART code: 7633 (715) 726-2544 Voice (715) 726-2549 Fax Ijansky@commerce.state.wi.us cc: Pc Collova Builders Inc NORTH- UNPLATTED LANDS N 250.84' 283.65' - 200.11' 231 cn \ 4,0 cos? 0 \ \ \ c~i+, ' ° / 0) 0) W " Cb \ 9~ ~px\ \ try W= P,IJ~ = V J N II \ ® w w CO N it w 1~ r.j C~ C.71 co co 0 W OD -n 44 0 N p ~ L4 C43 00 > En ti pe ED 3 0 -1-4 C` / s s. oe 14 '0~/ oral 0i N°Dr 14 OD in ~I v~~ 6a / o / /I ?9~ F L-i off c 'I cn O Iz I Z7, LPI% / ID N L_ _ ZL£ 3 90.L0 N I A~ sz~ -,Z_S'£6£_/Ij urO, _£L.00 N 0 ? rn~ I iN / / r- Iv ~ W w / / Gix (00 co K) I I \ C 0 w m O° \ p ~L 0398'19" E it I 0 N N > N rn I w Iz 4.1 03 N I F ~ z > / N I 0) w I c 01 150.32' N' - - M~ - - - - I I co " Ln rn ` \N NWC ,LS'£L£ M „9*C@N ~ I o I CA w I LM- I c~o 1O o OD _ S 46 C7~ 5 7'~M „zLO~ -4 tO Z «.v . N` to \ N N CO w w N I I I N NWs\ > it, IW L ~c ~ N 07-32-21 " E -J L- -J L C-1 yG0' L9Z 0p\` _ 56.21' 214.15' 112.60' zmoammem 5 g; ° 0 I ~M \ a\~ \ ~o 247.40' S 00'08'03" W 557.04' A 01119-0 L, '0 \ 1 682 O co o \ 6 11 \ UNPATTED LANDS wl~x I~ > N I 0) 0 P/ rr0 N I m NL! -2 I / L~N ' Iw / I o N Ln 4~ 0 G~ I I ° > I N ~v I / /A lI 1-n IO CY) 0 OD C52 CY) o cNir 3„65,~£.OOS \>0 iz ° o - DSO `CSC ~0, / \3s" z M„6S,t£.OON Cl \ u C>, to 0 On O w z co\ \ A \ \ ° > N 4' rn IN °I K) -4(A J~\ \ rY\I rn I~ m -,rndu - On Jame 1-5i 2005, Thomas-Nelson, CSTM, Environmental By Design-conducted-a soil and site evaluation- on property owned by Collova Brothers Inc., located in the SE 1141 SW 1/4, Section 5, T29N-17W, town of Hammond, platted as lot 8 of Farm View Ridge subdivision, this purpose being-to determine the highest level of seasonal soil saturation so that a_ POWTS might be installed: This investigation revealed that the soils were-only good foran-A+O-mound system through an interpretive determination as designated-by the- Wisconsin Department Of Commerce's Administrative Code, Comm 85. .1 1- . Backhoe pits were provided for three borings, 1 through 3, with interpretations of the sites suitability being -conducted by using soil redmcimorphic features, soil texture, soil structure, soil color pursuant to the guidelines-under Chapter-Comm 85 of the Wisconsin Administrative Code and using the USDA-NR4 S-soil descriptive system. During this field investigation the landscapes morphological features, vegetation, and hydrology was determined-for the purpose-of this Interpretive Determination as -defined-in Comm. 85.W2) -of the Wisconsin Administrative-Code Upon completion of the collected field-data, which included the accurate measurement of the sites featured- pararneters, this interpretive report have been developed for review. The intent is to-demonstrate that a-minunum of 6-inches of unsaturated soil-exists on this site and-any influencing factors on this would allow the compliant installation ofa mound system serving a residential- use for this property as allowed under Comm 83 A4(3)(b) of the Wisconsin Administrative Code. Locat Hydrology: The local hydrology of this site-is.influenced- by the average of 3£1 inches of precipitation .received. -The- soil- properties and localized topography both-influence-water movement-on this property. Seasonal issues such- as fsozen ground-and warm temperatures also have their influences during the winter months when the ground is frozen, there would be an accumulation of snow with any melting action running off the site on the surface of-the ground-. Spring rains would produce additional- surface runoff until the ground has thawed: Upon thawing, the influence on groundwater levels would be-minimal due to the location ofthe site with its limited upslope watershed. The 3 percent suffice slope would also aid the slower permeability of the- soils.- Summer temperatures and plant-growth- would provide removal- of soil. moisture- tluough- evaporation and evapotranspiration, Locat Geomorphology, Shit DiAurliaace, and Local Topography th The-geologic interpretgion-of this area-directly related to-the-glacial-geology of the-Eastern St. Croix Moraine, a ground moraine that was formed by the accumulation beneath the glacier and-resulted in a composition of stony, reddish-brown glacial drift. Post-glacial windblown silts famed loess deposits that overlays-this-till: Below tithe Cambrian-bedrock Prairie Du Chien formation; a dolitimized limestone formation. Soil forming activities have resulted in what- is known as the Northern Till Uplands soils resulting iii dark silty soils. The site was probably originally in-crop-production- prior to its-development: Currently itis planted-in- winter wheat with- stem heights being 2 to 3 feet in length. This hillside has a 3- percent slopes and was probably formed-as the advancing ice scoured the landscape, retreated, depositing the till-material, forming the rounded knobs of the hillside. P.O.W.T.S. RECE IV,7 J Conditionally APPROVED WU I "1 2005 DEPARTMENT OF COMMERCE SRS cTY & BLOGS. Olu. DIV SION OF SAFETY AND BUILDINGS SEE RRES NDEN y Soiil Series- and Mapping Units- The St. Croix CountySoil Survey has-mapped this area as being of F'reeon soil series, which-consisis-of gently sloping, moderately well-drained soils. These soils are on low ridges and foot slopes of ground- momines. They formed in silty sediment and the underlying, reddish sandy loam till. The FnB soils of this series are representative as described by the Soil- Survey and are represented-by, a surface layer that is approximately 8 inches of dark grayish brown silt loam. The subsurface layeris brown silt loam and about 10 inches thick. The subsoil-is about 16 inches thick. The upper part is dark brown, mottled, friable silt loam;-the middle part-is a_reddish -lawn,-mottled, friable to fur loam;-and the lower part-is reddish-brown,- mottled; firm loam: The substratum; to a depth of 60 inches, is yellowish-red, mottled, firm sandy loam. Data The soils evaluation report and system design have been included with this report. A copy of the USDA Soil Survey map that provides the soil=mapping unit described- above. ➢ A USES Topographic Map, revealing the topography of the site. -P6WTsite plan, representing the best location and layout of the system that best treats and distributes the- systems :discharge water - Government Reports Leroy Jansky, Wisconsin Department of Commerce Wastewater Specialist, hasvisited the site and fmind no reason not to support the site's soils and landscape position, being suitable for an A++O-mound septic system- AdditisHdBt nA fe ion-Unique to-the site During the evaluation- there wa& the- obser:vatim of biological- activity in_the form_of worm- burrows and roots. Worm- activity was recognized at a depth of l I inches in boring 1 and at a-depth of 1-0-inches in- boring two. Root activity was observed at 13 inches on boring 1, 14 inches on boring 2-, and 14 inches on boring 3. It is recognized that these biological activities are normally not apparent in zones that are saturated for long periods-of time. This-being a first year crop (winter-wheat) and a very wet spring these factors fiuthersupport-the suggestion that this portion of the profile dries quickly after a precipitation event: The three borings observed all had redox features between 4 to 8 inches in the 10yr3/3 silt loam and had ~ r redox- free soilsbelow from- 8 to 1-finches. in the sandy clay loams before-redox- features once again- c , t',~C ~.s ~ appeared-. Recommen&tions The recommendation for the site would be for the site to be chisel plowed to a depth of at least 1-5 inches so -as to breakup the soil interface and reorient the platy structure in a -more vertical position, thus aiding infiltration. From the upside slope of the system area, 30 inches of ASTM--C-33 sand- lift will be placid on the plowed area: This-provides the-36 inches of vertical- separation to-provide-the treatment of pathogenic- Organisms. The recommended-mound design-uses &linear loading rate of 4.5-gpd/#f-and- an-in-situ-soil application rate of 0.2gpd/ft . This will be accomplished by designing the absorption area to be long and narrow and extended the down slope toe area to a 4:1 dimension, effectively increasing the basal area and eliminating the chances of toe seepage. Additionally, the slope on the upper toe edge of the mound will be constructed so as to be a slope with a 3:1 side slope at each end and a 6:1 side slope for the I dimension (upper slope) at a point L/2 (this being the location at half the distance of the total length of the mound) so as to help divert surface water from the upper slope (See included suggested mound detail plan). Finally the design requires that a water diversion ditch be installed above the mound so as to divert surface waters from the upslope area This should be installed with a 5:1 slope, a width of eleven feet, and oriented so that it traverses the contour slightly, draining the run off water north and down slope of the mound area. Conclusions It is mz belief that the soils in the area of the proposed POWS will not be saturated above 6" for seven or more consecutive days for the following reasons: ➢ The described soils in this location supports some the mapped description, which represents in its description more sandy clay loams and silty clay in the substratum. The platy soils located at depths of 4 to 8 inches are probably due to farming practices and can be over come by the deep chisel plowing so as to reorient the clay particles in a more vertical orientation. ➢ The biological activity in the soil as represented by the roots and Earth Worm presence, suggest that the soil has not been saturated in the most recent history of the soils. These activities cannot survive in saturated conditions. ➢ A design with a long and narrow system representing a linear loading rate of 4.5 gallons per day per foot and an in-site soil application rate of .0.2gpd/ft2t. This configuration represents the best distribution of the wastewater, spreading it over a longer area. With the increased height of the mound, there is the assurance that there will be 3 feet of filtration between the bottom of the system and tlf zone of saturation. Also built into the plan is the increased dimension of the upslope of the mound, providing a 6:1 slope at the L/2 location, and the addition of a drainage ditch above the mound. These last two additional features will minimize surface runoff onto the mound area from higher elevations behind the system. The total design assures that the requirements of Comm. 83.41 of the Wisconsin Administrative Code are being met so as to properly filter the wastewater and to assure that there is no surface discharge, with discharge going below grade. The mound septic design and management plan provides proper treatment of wastewater and expected system longevity. Accordingly, the plan submittal addresses the methods and design for treatment and dispersal of the wastewater below the surface as addressed by the code requirements. The month of May and early June had a great number of rain event days and even with this unusual amount of precipitation the holes had no free water. Additionally, the redox features that were observed were progressively more intense deeper in the soils profile suggesting that the upper levels were redox features were observed were not saturated for as long of periods of time. The final authority for this site's approval rests with the appropriate regulatory agencies: the Wisconsin Department of Commerce and the St. Croix County Zoning officials. Thomas C Nel~p CST 227387 November 5 2005 alL ,sue MAV rA41L 53 Sr- N X CID. molt SM - -Po QU "A Oft" ++A~ ^MIW . Ski = i• M WE r - ~ F r 4f #rV ~~t}'~ ~ 'pL`+Y/!-,dam J„ ! Y .ka s ~ < ~ a 3y. T ~k:, a r5n eu r<'I^I . kY 'g 3Yt ~p~„~.a rN f~4Y-~-~Lw ¢ .Y - _ .'1'„ • ' k•• r + .h. ~ 4 +-X~... yT. J' r' \°k xy.1w t~ ~ r. Y ^ z r .~q - - say£ - V .rte y l(. • sf y 4i '3 a_ .'Z' m• Yom' L~~ 5 .T e k x d ,y•'gyt w ~ a T dt~ F r „i >b s ti Y w A:z r~ - - t Cry, ~e. ry ya+yft ,.t u a~i r.. d 4 •-i"`•"„~c ..,,•,{w.•.(tt fix. x. zi Y.i~Ss,.ar ~ Sri:. VIR A&I A , `YS r 4 y. 000, .v Ile s _ _ e. ~..-do" -.-a,,. _ .+Hr .~w, a~. ~ vi err i ! r .r ~a+ s' yi, i farm View Ridge BM1 top of Won pips 100.00 -OR of ftn Ol 99.50 In SCOtt' B2 98.DO B3 98.30' _IW V' 11'-slide diversion ditch {:1 dopes for the purpose of diverting surface water from. the back-side of the inew . NW lot corner -This ditch traverses the contour Um-wW drains -SW--of-the mound Mom area appraxirnatiy 22' 37' by 136' 701 -123' !0' -3fi6 IMP A 11' 41' -9930' B B' Ditch depth a' =bottom WidW AM MM I3WW -COTMy Thomas G Nelson 227387 Wisconsin Department of Commerce SOIL EVALUATION &&-X-0 page 1 Of 3 Division of Safety and Buildings in accordance witFh e CouSt. Croix Attadt complete sits plan on paper not less th an 8112 x must include, but not limited to: vertical and horizontal reference ion and arcel percent slope; scale or dimensions, north arrow, and locati[n;Qpr ~dPlease ptInt all iniMotmatleviewad bX Date Personal information you provide maybe used for secondary purpf~i Property Owner p ' PC Collova Builders Govt. Lot NW 1/4 SE 1/4 S 5 T 29 N R 17 E (or) W Property Owner's Madling Address Lot # Block # Subd. Name or CSM# PO Box 489 8 Farm View Ridge 7~ State 7 City p Code hone umber CRY Village ■ Town Nearest Road Somerset WI 54025 715-247-2742 70th Street Q New Construction Use Residential / Number of bedrooms 3 to 4 Code derived design flow rate 450 to 600 GPD Replacement Public or commercial - Describe: Parent material Loess over glacial till Flood Plain elevation if applicable NA ft. General comments Site has been determined to be an A+0 site, requiring an Interpretive Determination as allowed by the Wisconsin and recommendations` State Administrative Code, COMM 85 Boring # D Boring Q Pit Ground surface elev. 99:00 ft. Depth to limiting factor 5-8 & 12 in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/fF In. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Efr#1 *EM 1 0-5 10yr3/2 sil 2msbk mfr as if .6 .8 2 5-8 1 3/3 fld7.5yr5/6 sil 2msbk mfr as if .6 .8 3 8-12 10yr4/4 SO 2msbk mfr cw if .4 .6 4 12-28 10yr4/4 c2f7.5yr5/6 SO lmsbk mfr cw - .2 .3 5 28-32 10yr4/4 m2p7.5yr5/6 SO lmsbk - - - .2 .3 IT] Boring # Boring 99.80 4-8 &13 Q pit Ground surface elev. ft. Depth to limiting factor _ in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/fl: _ In. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Efl#1 *01#2 1 0-4 1Oyr3/2 sil 2msbk mfr as if .6 .8 2 4-8 1 3/2 ftd7.5yr5/6 sil 2msbk mfr as I f .6 .8 3 8-13 10yr4/4 scl 2msbk mfr cw 1f .4 .6 4 13-26 1Oyr4/4 c2f7.5yr5/6 scl lmsbk mfr - - 2 .3 ' Effluent #1 = BOD > 30 < 220 mg/L and TSS >30 150 mg/L * Effluent #2 = BOD < and TSS < 30 mg/L CST Name (Please Print) _ Signature CST Number Thomas C Nelson 227387 Address Date €valuation Conducted Telephone Number 1432 120th Street, New Richmond, WI June 15 2005 715-246-2454 J Property Owner PC Collova Builders Parcel ID # Pending Page 2 of 3 L~ Boring # Boring u Ground surface elev. 98.30 ft. Depth to limiting factor 4-8 &13 in. Pit Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/fF in. Munsell Qu. Sz. Cont. Color Or. Sz. Sh. *501 '€W 1 0-4 10yr3/2 - sil 2msbk mfr as 1 f .6 .8 2 4-8 i 3/2 fld7.5 5/6 sil 2msbk mfr as if .6 .8 3 8-13 2r4/4 - scl 2msbk mfr cw if .4 .6 4 13-29 10yr4/4 c2f7.5yr5/6 scl lrnsbk mfr - - .2 .3 Boring # P Boring Pit Ground surface elev. ft. Depth to limiting factor in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Moots 431150AF in. Munsell Ou. Sz. Cont. Color Gr. Sz. Sh. 'Eff#1 '1-=ff#2 ❑ Boring # Boring 1H Pit Ground surface elev. ft. Depth to limiting factor in. Soil Application Rate Horizon Depth Dominant Color Pedox Description Texture Structure Consistence Boundary Hoots GPDMF in. Munseli tau. Sz. Cont. Color Gr. Sz. Sh. 'Eff#1 'Eff#2 ' Effluent #1 = BODE > 30:5 220 mg/L and TSS 5-30 < 150 mg/L ' Effluent #2 = BOD5 < 30 mg/L and TSS < 30 mg/L The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or need material in an alternate format, please contact the department at 608-266-3151 or TTY 608-264-8777. 9BD=8330Test(R.07/00) Scale 1" . 30' . Farm View Ridge BM1 top of iron pie 1000BM2 Top of iron pipe ".30 B1 l9.80' Lot B2 0$.00' f33,N.30' 100' 98' Nut I NW lot corner B/M4 - T 22' " :Is 1 70' 123' 40' 3% 82 3W lot co SAFETY AND BUILDINGS DIVISION commerce.wl.gov Integrated Services Bureau 13 East Spruce Street isconsin INSPECTION REPORT www.commemmerce. 54/ b ww w6-ov/sb 2544 Department of Commerce (715) 72i.g Date of Inspection: June 9, 2005 Plumber Name and Address: Project Name: Collova Unknown Use: Residential Legal Description: NE-NW, SE, 5, 29, 17W Site Number: NA Subdivision: Lots 5, 8, 9, and 13-15, Certified Soil Tester Name and Address: Farmview Ridge Tom Nelson, CST 227387 Municipality: Town of Hammond 1432 120th Street County: St. Croix New Richmond WI 54017 Plan Transaction Number: NA Owner Name and Address: Sanitary Permit Number: NA P. C. Collova Builders PO Box 489 Wastewater Flow: 450 gpd Somerset WI 54025 Persons Present: T. Nelson An onsite soils verification was conducted at the above referenced site as per district policy for all sites with less than four inches of unsaturated soil below the bottom of the A horizon. The intent of this investigation is to confirm initial observations by the certified soil tester (CST) relating to the presence or absence of redoximorphic features in the A horizon and/or subsoil. In-situ soil texture, structure, and consistence factors were also reviewed as they relate to wastewater application rates. Other site conditions such as percent and direction of slope, landscape position, land surface contour length, and surface water hydrology may also be noted and their effects are factors considered in the recommendations and conclusions portion of this report. This investigation is the second one on these lots due to a change in certified soil testers and poor weather and lighting conditions on November 29, 2004, when the initial onsite investigation was completed. Lot 5 (A+2) 00-04" 10YR 3/2 sil, 2msbk, mfr, as. 04-07" 10YR 3/3 sil, 1 mpl, mfr, as. 07-09" 10YR 4/4 cl, 1 mpl, mfr, cw. 09-12 10YR 4/4 cl, 1 csbk, mfr, with f2f 10YR 5/6 rmfs. Lot 8-9 (A+0) 00-04" 10YR 3/2 sil, 2msbk, mfr, as. 04-08" 10YR 3/2 sil, 2msbk, mfr, as, with f1 d 7.5YR 5/6 rmfs. 08-11" 10YR 4/4 scl, 2msbk, mfr, no rmfs. Lot 13 (A+O) 00-06" 10YR 2/2 sil, 2csbk, mfr, cw. 06-12" 10YR 4/3 cl, 2mpl, mfr, w/ c2f 10YR 5/6 and 6/3 rmfs. Lot 14 (A<O) Similar to Lot 15 below except the subsoil lacks redox features for 3-4 inches below the A horizon. Possible plow pan tension saturation might be expected since no redox were observed immediately below the A horizon. Lot 15 (A<O) 00-06" 7.5YR 2.5/2 sil, 2msbk, mfr, cw 06-11" 7.5YR 2.5/2 sil, 3msbk, mfr, as, w/f2d 7.5YR 5/6 rmfs. 11-15" 7.5YR 4/3 cl, 1 csbk, mfr, f2f 7.5YR 5/6 rmfs. Page 2 of 2 June 9, 2005 P.C. Collova Site Two other hand borings on Lot 15 revealed similar conditions. Redox features were observed in the A horizon and in the subsoil below. If mound systems are designed to overcome limitations of a high level of seasonal soil saturation and slow permeability, the linear loading rate should not exceed 4.5 gpd/ft and the basal wastewater application rated should not exceed 0.2 gpd/ft2. The additional basal area will partially compensate for the gentle land slope and prevent wastewater leakage at the mound toe. At least 30 inches of sand lift is recommended when applying septic tank effluent to the distribution cell of the mound to ensure proper treatment. The longest portion of the mound must be orientated along the contour. The mound shall be constructed to divert surface water around the mound structure as much as possible. In addition, an up slope drainage ditch should be considered if it is determined that surface or subsurface hydrology is improved by intercepting water and diverting it away from the mound site. Deep chisel plowing may be needed to improve the permeability where a plow pan appears to restrict downward water movement. Special Comments: 1. The down slope toe of the proposed mound area on Lot 5 should be well clear of the drainage way. Soil conditions near the drainage way are very marginal for proper dispersal of effluent from a mound system immediately up slope. It is recommended that the proposed mound area be moved approximately 50 feet up slope. Property line boundaries would have to be reconfigured or an easement granted for placement of the mound on Lot 4. Soil tests would need to be redone to verify suitable conditions in the new area. 2. Even though I specified the maximum linear loading to be 4.5 gpd/ft, designers should try to design systems at 3.5 to 4.0 gpd/ft if possible. 3. Two soil borings in the proposed mound area on Lot 15 exhibited redox concentrations in the lower part of the A horizon and immediately below in the subsoil. This area is somewhat more level than other areas and more precipitation may infiltrate than on a sloping site. In addition, agricultural practices may have caused some compaction in the lower part of the A horizon and upper part of the B horizon. The combination of more infiltration and weak soil compaction may result in a higher level of saturation at this site than at other areas of the plat. Options include moving to another area on the lot, monitoring the area with observation pipes this next spring [see Comm 85.60(3) for requirements], or compiling a convincing explanation of why this is occurring and why it's not a problem for proper system operation. If there are any questions regarding this report, please contact me. Leroy G. Jansky, Wastewater Specialist cc: ❑ County ❑ Plumber Ljansky@commerce.state.wi.us E-mail ❑ CST ❑ Owner 715/726-2544 Voice 715/726-2549 Fax ❑ Other SOIL EVALUATION REPORT Page of Wisconsin Department of Commerce Division of Safety and Buildings in accordance with Comm 85, Wis. Adm. Code County mus Attach complete site plan on paper not less than 8 112 neainches Ml deed on andt Parcel I.D. include, but not limited to: vertical and horizontal ret n~ oad. percent slope, scale or dimensions, north arrow, ans locatgp r Reviewed by Date Please print all infoematron. _ ( ) Personal information you provide may be used for second ry purPOS?g fPriva Law. s 15104(1) ovation q Property Owner 114 114 ST O(/ N R E (or W 1 , ~r o V /-~Y JI :~ibVt. Lot Y slip OA=F l:kfl # Block# Subd. a c CSM# , Property Mailing Address _ / f Village Town Nearest Ro State , Zip Code Phone Number ❑ city ❑ ~ derived design flow rate GPD s New Construction us Residential / Number of bedroom Code ❑ Replacement ❑ Public or commercial - Describe: ~y ft Parent material Flood Plain elevation if applicable General comments _ and recommendations: .~i y S y (ti+, L? I 4-1-Y -7 m 0 k4 J ring Boring # ~ ft. Depth to limiting factor in. Soil Application Rate Pit Ground surface elev. ~ L,~J Texture Structure Consistence Boundary Roots GPD/fF Horizon Depth Dominant Color Redox Description Gr. Sz. Sh. •Eff#1 •Eff#2 in. Munsell Qu. Sz. Cont. Color L G N// jrff Boring # Pit Ground surface elev. i ft. Depth to limiting factor _ in. Soil lication Rate © Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots •Eff#1 GPI•Eff#2 in. Munselt Qu. Sz. Cont. Color Gr. Sz. Sh. Effluent #1 =BOO > . 220 mglL and TSS >30:! 150 ' Effluent #2 = A0D < 30 mg/L and TSS ` 30 mg/l 30 CST Number CST Alarms (Please Print) Si re 2T Numb Bird Plumbing, Inc. Shaun Bird 22 Number Date Evaluation Conducted Telep Address 715-246-4516 1008 192nd Ave, New Richmond, WI 54017 I Parcel ID # Page c, R, of Property owner Boring n Boring # f 0,2. 3ft• Depth to limiting factor in. Soil AplAication Rate A pit Ground surface elev GPDM Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots .EfI#1 *Eff#2 in. MunseII ()u. Sz. Cont. Color Gr. Sz. Sh. F Boring # Boring Depth to limiting factor in. Soil Application Rate ❑ Pit Ground surface elev. ft- Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ff Gr. Sz. Sh. •Eff#1 'Eff#2 in. Munsell Qu. Sz. Cont. Color Boring In. Boring # Ground surface elev. ft. Depth to limiting factor Sod Application Rate ❑ pit Horizon Depth Dominant Col Redox Description. Texture Structure Consistence. Boundary Roots Gin. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. `Eff#1 • = <_30 nVIL • Effluent #1 = BODE > 30 1220 mglL and TSS >30 < 150 mglL Effluent #2 BODs c -30 nrglL and TSS ssistance The Department of Commerce is an equaOpportunity ease service provider department at 608-26b 3151eord aTTY 608-264-8777. services or need material in an alternate format, please SOD4330 (86/00) ` k r ' Soil Test Plot Plan Project Name P.C. Collova Bldrs. Inc. Sha Bir Address P.O. Box 489 , Somerset Wi 54025 C~fM #226900 Lot 8 Subdivision Farm View Ridge Date 5/8/04 NW 1/4 SE 1/4S 5 T 29 N/R17 W Township Hammond ❑ Boring Q Well PL Property Line County ST. CROIX BM or VRP Assume Elevation 100 ft. Top of Survey Iron System Elevation 103.8' *HRpSameasBenchmark Alternate Benchmark Top of 1/2" Pipe 4 100.2' Scale is 1" = 40' unless otherwise Pro noted Property Line 102' System contour line of 101.3' 101' B-2 Pro O Property Line 4% Slope Former lot corner for Lot 8/9, lot is to be redesigned to include this soil test 1:1 B-1 B. M. Pro Property Line All. . commerce.wi.gov %Integrated AFETY ANDBUILDINGS DIVISION Services Bureau 13 East Spruce Street i C. ippews Falls, WI 54729 s consin INSPECTION REP VEC p 3 t?• - COm (~i5 '72&2544 Department of Commerce o Q E Date of Inspection: November 29, 2004 Plumber ~Q Project Name: Collova Unkn Use: Residential Legal Description: NE-NW, SE, 5, 29, 17W Site Number: 692118 (Lot 5) Certified Soil Tester Name and Address: Subdivision: Lots Lots 5 5, , 8, 9, and 13-15, Farmview Ridge Shaun Bird CST 226900 Municipality: Town of Hammond 1008 192 Ave County: St. Croix New Richmond WI 54017 Plan Transaction Number: 1079283 (Lot 5) Owner Name and Address: Sanitary Permit Number: NA P. C. Collova Builders PO Box 489 Wastewater Flow: 450 gpd Somerset WI 54025 Persons Present: S. Bird, P. Quinn An onsite soils verification was conducted at the above referenced site as per district policy for all sites with less than four inches of unsaturated soil below the bottom of the A horizon. The intent of this investigation is to confirm initial observations by the certified soil tester (CST) relating to the presence or absence of redoximorphic features in the A horizon and/or subsoil. In-situ soil texture, structure, and consistence factors were also reviewed as they relate to wastewater application rates. Other site conditions such as percent and direction of slope, landscape position, land surface contour length, and surface water hydrology may also be noted and their effects are factors considered in the recommendations and conclusions portion of this report. Soil samples were taken from the approximate midpoint in the staked mound areas and reviewed under florescent fight at my office. Typical soil profiles could be described as follows: Lot 5 00-04" 10YR 3/2 sil, 2msbk, mfr, as. 04-07" 10YR 3/3 sil, 1 mpl, mfr, as. .07-09" 10YR 4/4 cl, 1 mpl, mfr, cw. 09-12 10YR 4/4 cl, 1 csbk, mfr, with f2f 10YR 5/6 rmfs. Lot 8-9 00-07" 10YR 3/2 sil, 2msbk, mfr, as. 07-10" 10YR 4/6 cl, 2msbk, mfr, as, with c3d 7.5YR 5/6 rmfs. 10-14" 7.5YR 4/6 scl, 2msbk, mfr, with c3f 7.5YR 5/6 rmfs. Lot 15 00-04" 10YR 3/2 sil, 2msbk, mfr, as. 04-07" 10YR 3/2 sil, 2f-mpl, mfr, as, with c2d 5YR 4/6 rmfs 07-12" 10YR 3/3 cl, 1 csbk, mfi, c2d 7.5YR5/6 rmfs If a mound system is designed to overcome limitations of a high level of seasonal soil saturation and slow permeability, the linear loading rate should not exceed 4.5 gpd/ft and the basal wastewater application rated should not exceed 0.2 gpd/ft2. The additional basal area will partially compensate for the gentle land slope and prevent wastewater leakage at the mound toe. At least 30 inches of sand lift is recommended when applying septic tank effluent to the distribution cell of the mound to ensure proper treatment. The longest portion of the mound must be orientated along the contour. The mound shall be constructed to divert surface water around the mound structure as much as possible. In addition, an up slope drainage ditch should be considered if it is Page 2 of 2 November 29, 2004',-4 P.C. Collova:SiteA A. determined that.surface, ovaUbsurface hydrology is improved by intercepting water and diverting it away from the mound site. Special Comments: 1. The down slope toe of the proposed mound area on Lot 5 is very close to a drainage way. Soil conditions in this area are very marginal for proper dispersal of effluent from a mound system immediately up slope. It is recommended that the proposed mound area be moved approximately. 50 feet up slope. Property line boundaries would have to be reconfigured or an easement granted for placement of the mound on Lot 4. Soil tests would need to be redone to verify suitable conditions in the new area. 2. Even though I specified the maximum linear loading to be 4.5 gpd/ft, designers should try to design systems at 3.5 to 4.0 gpd/ft. .3. Two soil borings in the proposed mound area on Lot 15 exhibited redox concentrations in the lower part of the A horizon. This area Is somewhat more level than other areas and more precipitation may infiltrate than on a sloping site. In addition, agricultural practices may have caused some compaction in the lower part of the A horizon and upper part of the. B horizon. The combination of more infiltration and weak soil compaction may result in a higher level of saturation at this site than at other areas of the plat. Options include moving.to another area on the lot, monitoring the area with observation pipes this next spring [see Comm 85.60(3) for requirements], or compiling a convincing explanation of why this is occurring and why it's not a problem.for proper system operation. If there are any questions regarding this report, please contact me. eroy G. +ns cy, stewa pecialist cc: ® County ❑ Plumber Ljansky mmer estate. i. s E-mail © CST ® Owner 7151726-2544 Voice 715/72t-2549 Fax ❑ Other I opo%one - i ne wen's 1 opograpnic iviap rage ui too -r TJ; E Nli 0 0.1 0.2 0.3 0.4 0.5 km 0 0.09 0.18 0.27 0.36 0.45 mi Map center is UTM 15 542300E 4985948N (WGS84/NAD83) Jewett quadrangle M=0.713 Projection Is UTM Zone 15.NAD83 Datum G=0.38 http://www.topozone.com/print.asp?z=15&n=4985948.00014833&e=542300.000000003&... 12/1/2004 $O)L saam!5 y ST• C~ l)C Co. Solt,. SukVF-y • 1-6 B FRSlg*j cy1_ '"6"1 S-48POMIAM 2'4 Stap{Ly APAc . SCALD 8 M = M1L~ J S a Jews'tt S{1. Sway !VA ST" M#4 2 J e B JewsTr s1u z. s L t A- I.AtwL><R S{L 6^3'~e S1.etPE$ V q,.QLA$AT'( S{L 2-t.o Sles JVL.. Q u,~ 4rFf 3 I ~ f 4 L^7» 61.E a ~t t g, FoE3 91 vo ' 5~ sr 4 T i y ~t~ly a~ S t r t ~i era s.'~€x# ~ z ~ ~A S ~ ins Safety and Buildings Division commercemi. 13 E. Spruce Street gov Chippewa Falls, WI 54729 www.commerce.wi.gov/sb Itisconsin Jim Doyle, Governor Department of Commerce Cory L. Nettles, Secretary November 16, 2004 CUST ID No. 226900 Fee Required $ 100.00 Fee Received $ 100.00 Balance Due $ 0.00 WiSMART code: SHAUN R BIRD BIRD PLUMBING, INC 1008 192 ND AVE NEW RICHMOND WI 54017 REQUEST FOR ADDITIONAL INFORMATION SITE: PC Collova Builders Town of Hammond, St Croix County S 1/2, NE 1/4, S5, T29N, R17W Identification Numbers Lot: 8, Subdivision: Farmview Ridge Transaction ID No. 1079361 Site ID No. 692132 FOR: Object Type: Soil Saturation Determination Please refer to both identification Regulated Object ID No.: 991436 numbers, above, in all correspondence with the agency. The submittal described above has been placed on HOLD and the review and approval is pending subject to receipt of the ADDITIONAL INFORMATION and/or revised plans requested by this letter. Upon receipt of the additional information and/or revised plans, the plans will be reviewed for compliance to applicable Wisconsin Administrative Codes and Wisconsin Statutes. The following must be corrected/revised and accompany'the resubmittal: 1. The Interpretative Determination report does not adequately show that this lot has at least 6 inches of suitable soil for a mound system. The narrative has a number of discrepancies, errors, omissions, and inconsistencies that need to be addressed prior to approval. The submitted may want to consider engaging a licensed professional soil scientist to help with submittal of the revised report. See comments on the report submitted under Transaction Number 1079283 for further explanation. 2. It would be very helpful to have a full-size copy of both the preliminary and final plat maps for this subdivision. SHAUN R BIRD Page 2 11/16/2004 3. Submit three (3) properly sealed, legible, and permanent copies of all revised documents for review. Send your resubmittal into the address listed above, unless otherwise noted, and the department will review the resubmittal within 5 working days of receipt date. Please include a copy of this letter with your resubmittal. If you have any questions, after reading the above comments and related code sections cited, please call me at the telephone number below. If the above requested information and/or plans are not received within 30 business days of the date of this correspondence, this submittal will be returned denied. No fees will be refunded, and a new fee, application form, and submittal of plans/specifications will be required should you desire to continue with this project. The code in effect at the time of new submittal would apply. Sincerely, Leroy G. Jansky, RPSS, Wastewater Specialist Integrated Services Bureau (715) 726-2544 Voice (715) 726-2549 Fax Ijansky@commerce.state.wi.us cc: PC Collova Builders Inc Zoning Office St Croix County SPIA