Wisconsin Department of Commerce SOIL EVALUATION REPORT Page 1 of 3
Division of Safety and Buildings in accordance with Comm 85, Wis. Adm. Code Steel Sal Service
Attach complete site plan on paper not less than 8% x 11 inches in sae. Plan must County St. Croix
include, but not limited to: vertical and horizontal reference point (BM), direction and
percent slope, scale or dimensions, north arrow, and location and distance to nearest road. Parcel I.D. 02-10 _ /j riding Z 2- OLD
Please print all information. R Date
Personal information you provide may be used -,dary purposes (Privacy Law, s. 15.04 (1) (m)). ' 3 2^~ 03
r-
Property Owner Pr Location
LaCasse Development, Inc. ovt' Lot NE 1/4 SW 1/4 S 13 T 29 NR 19 W
Property Owner's Mailing Address A U G j Lot Block # Subd. Name or CSM#
573 Cty Rd " A" 2002 2 na Alexander Meadows
City State Zip ode PfioW~~nUNTY Village Town Nearest Road
Hudson WI Z I &IF- 5 Hudson Alexander Rd.
_ New Construction Use: Residential / Number of bedrooms 4 Code derived design flow rate 600 GPD
Replacement Public or commercial - Describe:
Parent material Glacial Drift Flood plain elevation, if applicable na
General comments
and recommendations: mound design, system elevation 96.75 ft based on contour line elevation 95.75 ft
i-~~ nAe,~- c"-4~ O/Z ?1*136 44)~~
Boring /
❑ Boring #
110' Pit Ground Surface elev. 96.55 ft. Depth to limiting factor 72 in.
Fsnit Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
*Eff#1 *Eff#2
1 0-8 10yr3/2 none sil 2msbk mfr cs 1f .5 .8
2 10yr4/4 none sl 1 csbk mvfr gw na 4) .6
3 36-72 7.5yr4/4 none Is osg mvfr gw na .7 1.2
4 72-96 7.5yr4/4 c2d 7.5yr5/6 scVsl 2msbk mfr na na .4 .6
Horizon # 4 has stratified layers
Boring # Boring
Ile Pit Ground Surface elev. 96.55 ft. Depth to limiting factor 26 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
*Eff#1 *Eff#2
1 0-8 10yr3/2 none sil 2msbk mfr cs 1f .5 A
2 8-26 10yr4/4 none sl 1 csbk mvfr gw na .4 .6
3 26-96 7.5yr4/4 none scvsl 2msbk mvfr gw na .4 .6
Horizon # 3 has stratified layers
* Effluent #1 = BOD 5> 30 < 220 mg/L and TSS >30 < 150 mg/L * Effluent #2 = BOD5< 30 mg/L and TSS < 30 mg/L
CST Name (Pk?ase Print) Signature: CST Number
David J. Steel 248956
Address Steel Sal Service Date Evaluation Conducted Telephone Number
1564 CR GG, New Richmond, WI 54017 8/3/2002 175-246-5085
Property owner L.aCasse Development, Inc. Parcel ID # pending Page 2 of 3
3 ] Boring # Boring
jej Pit Ground Surface elev. 93.95 ft. Depth to limiting factor 72 in. Sod Application Rate
F
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/112
*Eff#1 *Eff#2
1 0-16 10yr3/2 none sl 2msbk mfr cs 1f .5 .9
2 16-26 10yr3/3 none sil 2msbk mfr gw 1vf .5 .8
3 26-58 10yr4/4 none sicl 2msbk mfr gw na .4 .6
4 58-72 7.5yr4/4 none Cl 2msbk mfr gw na .4 .6
5 72-78 7.5yr4/4 c2d 7.5yr4/4 Ifs 1 csbk mvfr CS na .4 .6
6 78-96 7.5yr4/6 none Is osg mvfr na na .7 1.2
F Boring # Boring
Pit Ground Surface elev. ft. Depth to limiting factor in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
*Eff#1 *Eff#2
i
❑ Boring # Boring
Pit Ground Surface elev. ft. Depth to limiting factor in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
*Eff#1 *EM
Effluent #1 = BOD 5> 30 < 220 mg/L and TSS >30 < 150 mg/L * Effluent #2 = BOD5 <30 mg/L and TSS <_30 mg/L
The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
Page 3 of 3
STEEL'S SOIL SERVICE.
David J. Steel 1564 Cty Rd GG
CST-POWTSM LaCasse Dev., Inc. New Richmond, W15401°7
Lic. it 248956 NF,1./4,SW1/4,51.3,-129,It.1.9W (7-15) 246-6200
Town of Hudson, St. Croix Co. (715) 246-5085
Alexander _Meadows,,Lot -22
This soil evaluation was conducted to satisfy a zoning requirement, it may or may not be suitable for
your use. The location of the test may or may not be as shown -as permanent tot lines were not
N
bushed at the time the test was conducted.
L/O
A= j5te" • k r ~C
I op rr'Zt~ G ~"Re-
:5 fOr
? ,,,(OA Bogy;njjS
I A ~a ~6rin5 fteAfions
Tat gG.55'~I-
s
f
.5110 Est ~
si Q
~3 rs5'
AREA
'
47
61~rr3`
CL 96'.
To Ce
3-a v