HomeMy WebLinkAbout020-1479-21-000 (2)
NVIsconsin SOIL EVALUATION REPORT #2007
Department of Commerce in accordance with Comm 85, Wis. Adm. Code Page 1 of 3
Steel's Soil Service
Division of Safety and Buildings
County
Attach complete site plan on paper not less than 8% x 11 inches in size. Plan must St. Croix
include, but not limited to: vertical and horizontal reference point (BM irection and parcel I.D. 2 0 q
percent slope, scale or dimensions, north arrow, and location and ace to nearest road. O 1~ 01
Please print all informatio ~Q Revie d By Da e
Personal information you provide may be used for seconp c~s (Privacy Law, 15.04 (1) (m)). Z`~ O~
Property Owner Prope X Location
Bast, Kernon 6 vt. L na SE1/4, W1/4, S36, T29N, R19W
Property Owner's Mailing Address GOB Lot # Block # Subd. Name or CSM#
948 Labarge Rd. 21 na Cottonwood Ridge South
City State Zip Code Phumb L] City ❑ Village E\] Town Nearest Road
Hudson WI 54016 71 6-7775 Hudson Cty Rd N
New Construction Use: 'LVJ Residential / Number of bedrooms 4 Code derived design flow rate 600 GPD
Replacement El Public or commercial - Describe: na
Flood plain elevation, if applicable na ft.
Parent material outwash plains and stream terraces
General comments Conventional system , sytstem elevation 94.64ft. Trenches spaced and depth to code 4.41 ft below grade.
and recommendations: -
❑ Boring #
Ground surface elev. 99.05 ft. Depth to limiting factor 110 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2
1 0-12 10yr3/1 none sil 2msbk mfr Cs if .6 .8
2 12-31 10yr4/4 none Sid 2msbk mfr Cs na .4 .6
3 31-44 7.5yr4/4 none sl 2msbk mfr Cs na .6 1.0
4 44-52 7.5yr4/6 none grCos osg mvfr Cs na .7 1.6
5 52-110 7.5yr4/6 none ms osg ml na na .7 1.6
.l
11 ~ 0
Z
❑ Boring #
Ground surface elev. 99.05 ft. Depth to limiting factor 110 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2
1 0-11 10yr3/1 none sil 2msbk mfr Cs lvf .6 .8
2 11-25 10yr4/4 none Sid 2msbk mfr gw na .4 .6
3 25-53 7.5yr4/4 none gr cos osg mvfr gw na .7 1.6
4 53-110 7.5yr4/6 none ms osg ml na na .7 1.6
cod
52
* Effluent #1 = BODS> 30 < 220 mg/L and TSS >30 < 150 mg/L * Effluent #2 = BOD5 < 30 mg/L and TSS S30 mg/L
CST Name (Please Print) Signature: CST Number
David J. Steel 248956
Address Steel's Soil Service Date Evaluation Conducted Telephone Number
994 200th St. Baldwin, WI 54002 10/21/2006 715-760-0347
SBD-8330 (R.07/00)
Property Owner Bast, Kernon Parcel ID # Pending Page 2 of 3
❑ Boring # Z Ground surface elev. 98.15 ft. 1 Depth to limiting factor 110 in.
~ Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2
1 0-15 10yr3/1 none sil 2msbk mfr cs 1Vf .6 .8
2 15-38 10yr4/4 none Sid 2msbk mfr gw na .4 .6
3 38-60 7.5yr4/4 none gr cos osg mvfr gw na .7 1.6
4 110 7.5yr4/6 none ms osg ml na na .7 1.6
~l
~ ~ III
❑ Boring # C Ground surface elev. ft. Depth to limiting factor in.
CI Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2
❑ Boring # E' Ground surface elev. ft. Depth to limiting factor in.
C' Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2
* Effluent #1 = BOD> 30 < 220 mg/L and TSS >30 < 150 mg/L * Effluent #2 = BODs < - 30 mg/L and TSS < 30 mg/L
e- - -
The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
need material in an alternate format, please contact the department at 608-266-3151 or TTY 608-264-8777.
SBD-8330 (R.07/00) Steel's Soil Service
STEEL'S SOIL SERVICE 3 of 3
David J. Steel Kennon Bast 994 200th St.
CST-POWTSM SW1/4,SE1/4,S36,T29N,R19W Baldwin, WI 54002
Lic. #248956 Town of Hudson, St Croix Co. Direct 715-760-0347
Cottonwood Ridge South, Lot 21 Fax 715-684-3449
This soil evaluation was conducted to satisfy a zoning requirement, it may or may not be suitable for your use.
The location of this test may or may not be as shown, as permanent lot lines were not established at the
time the soil test was conducted.
Legend N
1" = 40'
= Benchmark Ele. 100.00 ft
Top of 3/4" pvc pipe
• = Alt Benchmark Ele. 100.00 ft
Top of 3/4" pvc pipe
❑ =Borings
Boring Elevations
BI = 99.05 ft
B2 = 99.05 ft
r B3 = 98.15 ft
B4 = 0.00 ft
g I
3
S nor S
~ C
~i-o-6
x
x
I x
046.3
x
N
1 10 8. RAIN BI
~ o s
87313
C.B.A. = 0 A
3.46 Acres 100.7
f [I,O4
150786 sq. @❑~o~o
.A. 3.4
LB O 1040. X .4 0
}grJrl g - - - -
~o
20
2.84
123840 sq.ft
2.39 Acres C. . . _ Q.8 AC. 2.64 ores N
103959 sq. ft ~'~~0=1 0 14792 ft
I ~
X32 C BO= 1042.00 C.B. = 2.6 C. .20 Ac
X sq. ft
1039.0 C.B.A. 2.2 AC.
1vv i 2
NG PIT DEPTH 15'
.7 POND
X
X - j
37-1211.39" 211. 1040. 4.
- - I -j i
_ - 16386-`- - -
•
330.00'
STe CROIX .&A I
PLANNING & ZONING
November 19, 2009
Kernon Bast
c/o Edina Realty, Inc.
400 South 2nd Street
Hudson, WI 54016
Code Administration RE: Compliance deposit refunds for Cottonwood South '07 lots
715-386-4680 Section 36, Town of Hudson
Land Information 6- Dear Mr. Bast:
Planning
715-386-4674
1 recently reviewed the Board of Adjustment Decision for the above subdivision while
RealPropcm processing a sanitary permit application and noted that you have compliance deposits that
715-38o-4677 may be eligible for refund. According to Condition #5:
Re; yeling "The plan shall be accompanied by a $100 nonrefundable staff review fee and a cash
715-386-4675 compliance deposit for the lot. The compliance deposit for the six lots under construction
shall be $1,100 each, and the compliance deposit for the remaining lots in the subdivision
shall be $300 each. The cash compliance deposit will be held by the Zoning Administrator
until construction is complete, permanent vegetation has been established, and the project
is found to be in compliance with the conditions of this approval, at which time the deposit
will be refunded in full. Upon completing construction on each lot, the applicant shall submit
to the Zoning Administrator photos of the completed construction and certification from the
project engineer that the construction has been completed as approved to serve as proof of
compliance."
Our sanitary database records show eight (8) permits were issued whose POWTS have
been installed and inspected. However, there are some non-compliance issues that must
be resolved before lots 2 and Int 24 will be considered "complete". We need to obtain
elevations and documentation of the building sewer and tanks that were installed on lot 24
without county inspecto and the mound on lot 2 does not meet the required setback from
7 v
the north lot line. L G4~ W` 2 9
When we have received photos that document completion of construction on each lot, your
deposit refunds will be processed.
S' ely,
Pam- Quinn
Zoning Specialist
Cc: Brian & Molly Hayes, lot 24 property owners
Andre Buechner, lot 2 property owner
ST. CRO1X COUNTY GOVERNMENT CENTER
1 10 1 CARMICHAEL ROAD, HUDSON, Wi 54016 715386-4686 FAX
PZPCO. SA/NT-CRO/X. W1 US
WWW.CO.SAINT-CROIX WI US