Loading...
HomeMy WebLinkAbout026-1306-00-047 (2) •NNAsconsin SOIL EVALUATION REPORT #1518 Department of Commerce in accordance with Comm 85, Wis. Adm. Code ge 1 of 3 Division of Safety and Buildings Schmitt Soil Testing, Inc. Attach complete site plan on paper not less than 8'/ x 11 inches in size. Plan must County St. Croix include, but not limited to: vertical and horizontal reference point (BM), direction and percent slope, scale or dimensions, north arrow, and location and distance to nearest road. Parcel I.D. 47 Please print all i o- Re wed y Dat Personal information you provide may be used for ry purpo ~ AQW, s. 1 .04 (1) (m)). /Z Cfp Property Owner Prope Location Sienna Corporation SEP 2 6 200 Govt. of N 1/4, SE1/4, S18, T30N, R18W Property Owner's Mailing Address ST. CROIX COON Lot # Block # Subd. Name or CSM# 4940 Viking Drive Suite 608 4 The Glens Of Willow River City State Zip C Cri'Y E] Village ❑ Town Nearest Road Minneapolis MN 55435 Richmond 95Th St. ❑ New Construction Use: Residential / Number of bedrooms 3 Code derived design flow rate 450 GPD ❑ Replacement ❑ Public or commercial - Describe: Parent material Outwash Flood plain elevation, if applicable na tt. General comments and recommendations: Area is suitable for a conventional system with a 0.7 gpd/ sgft rating. Possible system elevation for Area 1 is (step trenches) high trench 95.50', low trench-RU. ~r '6 7.• Z F-11 Boring # ❑ Boring ❑ Pit Ground surface elev. 98.72 ft. Depth to limiting factor 105+ in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPDM2 in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2 1 0-8 10yr3/2 none sl 2fsbk mfr as 2vf .6 1.0 2 8-17 10yr4/4 none sl 2msbk mvfr Cs 3vf .6 1.0 3 17-47 10yr5/6 none Cos Osg ml Cs .7 1.6 4 47-57 10yr5/4 none vgrCOS Osg ml Cs .7 1.6 5 57-105 10yr6/4 none s Osg ml .7 1.6 a Boring # Boring ❑ Pit Ground surface elev. 98.72 ft. Depth to limiting factor 102+ in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ftz in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. *Eff#1 *Eff#2 1 0-11 10yr3/2 none A 2fsbk mfr as 2vf .6 .8 2 11-20 10yr3/4 none vgls icsbk mvfr gw 2vf .7 1.6 3 20-76 10yr5/4 none grcos Osg ml Cs .7 1.6 4 76-102 10yr6/4 none s Osg ml .7 1.6 n . tp is . * Effluent #1 = BOD 5> 30 < 220 mg/L and TSS >30 < 150 mg/L * Effluent #2 = BOD5 s30 mg/L and TSS <_30 mg/L CST Name (Please Print) Signature: CST Number Thomas J. Schmitt 227429 Address Schmitt Soil Testing, Inc. Date Evaluation Conducted Telephone Number 1595 72nd Street New Richmond, WI 54017 9/18/2006 715-247-2941 ssn-8330 (307100) Property Owner Sienna Corporation Parcel ID # 47 Page 2 of 3 Boring # ❑ Boring ® Pit Ground surface elev. 92.62 ft. Depth to limiting factor 98+ in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft' in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. 'Eff#1 *Eff#2 1 0-17 10yr3/1 none sl 2fsbk mvfr as 2f .6 1.0 2 17-40 10yr4/4 none sl 3msbk mvfr gw ivf .6 1.0 3 40-47 10yr4/6 none sl 2msbk mvfr cs 1vf .6 1.0 4 47-98 10yr6/4 none s Osg ml as .7 1.6 5 98+ 2.5y7/2 none vfs Osg ml .4 .6 Z ~l ti -7 a 1,4 ❑ Boring # ❑ Boring Pit Ground surface elev. ft. Depth to limiting factor in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft' in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. •Eff#1 'EfW ❑ Boring # El Boring El pit Ground surface elev, ft. Depth to limiting factor in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2 in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. 'Eff#1 'EfW Effluent #1 = BODS> 30 < 220 mg/L and TSS >30 <150 mg/L " Effluent #2 = BODS < 30 mg/L and TSS <_30 mg/L The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or need material in an alternate format, please contact the department at 608-266-3151 or TTY 608-264-8777. SBD-8330 (807/00) SChmftt SON TeOV, BK. Page .3 of j Conducted by: Conducted For: Schmitt Soil Testing Inc. Name: Sienna Corporation Thomas J. Schmitt, CST 227429 Address: 4940 Viking Drive Suite 608 1.595 72nd St. City, State, Zip: Minneapolis, MN 55435 New Richmond, Wl. 54017 Phone: 715-247-2941 Subd.Name: The Glens of Willow River ' y7 Signature: ~ Lot No.: Date: Legal Description: rY4✓114 SE1/4 S18 T30N R18W Backhoe pit Township, County: Richmond, St. Croix A Bench Mark El. 100.00' Top of 2" pvc pipe Z~ Alternate Bench Mark El. 9 7v Top of Slope= / P. Contour Line El. /V14 Contour Line Length Scale V = 40' P`'-posQo R4~~ q ~t I p yd I R I q O 5~ g3 q~p I 1 ,a too a 6) ThisSoiland ite Evaluation was completed to fulfill a zoning requirement. It mayor may not be in a location suitable for you use.