Loading...
HomeMy WebLinkAbout026-1064-40-300 Wisconsin Department of Industry, SOIL AND SITE EVALUATION R E P O R T Page 1 of 3 (Labor and Human Relations D' 'ion f S fety & Bui i s y .0, yy~~ ord with ILHR 83.05, Wis. Qdm. Code /2 n 71W ✓ ~ r 9 g 4 then ) ~~rrk COUNTY Attach complete site plan on paper not less than 8 1/2 1 inc e~ ize. Plan mus include, but St. Croix not limited to vertical and horizontal reference point (BM), direction and % of slope, scale or PARCEL I.D. # dimensioned, north arrow, and location and distance to nearest road. 026-1064-40-9G9__ APPLICANT INFORMATION-PLEASE P %t.. ATION R VIEWED BY DATE /59 PROPERTY OWNER: PROPERTY LOCATION David Waldroff' GOVT. LOT NW 1/4 SW 1/4,S 21 T 30 ,N,R 18 xk(or) W PROPERTY OWNER':S MAILING ADDRES LOT # BLOCK # SUBD. NAME OR CSM # d9 3 na csm 3 3 71 398 River Rd. _ 1 CITY, STATE ZI ft0 E P N N M []CITY []VILLAGE MOWN NEAREST ROAD ~~36 Hudson, WI. 54016 n ¢ 01 Richmond 112th. st. [x] New Construction Use [x ] Resi }ia Numtte Ft ropm§ , i 4 [ ]Addition to existing building r_ie7ci~alttfes~f' j ] Replacement [ ] Public o Code derived daily flow 600 gpd ecommended design loading rate .7 bed, gpd/ft2 .8 trench, gpd1ft2 Absorption area required 858 bed, ft2 750 trench, ft2 Maximum design loading rate .7 bed, gpd/ft2 .8 trench, gpd/ft2 Recommended infiltration surface elevation(s) 96.40 trenches ft (as referred to site plan benchmark) Additional design/ site considerations trenches spaced to code 4.0' below surface el. Parent material outwash Flood plain elevation, if applicable na ft S = Suitable for system CONVENTIONAL MOUND IN-GROUND PRESSURE AT-GRADE 7SYSTEM IN FILL HOLDING TANK U = Unsuitable fors stem ®S ❑ U ® S ❑ U ® S El U ® S El U ®S ❑ U 13 S CRU SOIL DESCRIPTION REPORT Depth Dominant Color Mottles Structure GPD/ft Horizon Texture Consistence Boundary Roots Boring # in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. Bed Trench 1 0-7 10yr2/2 none 1 lcsbk mfr gw 1f .4 .5 2 7-15 10yr4/4 none sicl lcsb mfr cs if .2 I .3 Ground 3 15-28 7.5yr4/4 none ms Osg M1 9W na .7 .8 1le.4ft. 4 28-34 10yr5/4 c2p 7.5yr5/8 sil M na gw na np .2 Depth to 5 34-84 7.5yr4/6 none ms Osg ml na na .7 I .8 limiting factor +84" ya v Remarks: Boring # 1 0-10 10yr3/3 none 1 lcsbk mfr cs if .4 .5 2 10-15 10yr4/4 none sicl lcsbk mfr cs if .2 .3 3 15-34 7.5yr4/4 none ms Osg m1 gw na .7 .8 Ground elev. 4 134-41 10yr5/4 c2p 7.5yr5/8 sil M na gw na np .2 100.4ft. 5 41-84 7.5yr4/6 none co s Osg ml na na .7 .8 Depth to limiting factor y 4 ~ Remarks: CST Name:--Please Print Gary L. Steel Phone: 715-246-6200 Address: 1554 200th. Av New Richmorkd, WI 54017 Signature: Date: 4-28-99 CST Number: m02298 PROPERTY OWNER David Waldroff SOIL DESCRIPTION REPORT Page 2 of 3 PARCEL I.D. # 026-1064-40-000 - Boring # Horizon Depth Dominant Color Mottles Texture Structure Consistence Bou day Roots GPD/ft in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. Bed Trench 1 0-9 10yr3/3 none 1 lcsbk mfr cs if .4 .5 3 2 9-19 10yr4/4 none sicl lcsbk mfr cs if .2 .3 Ground 3 19-30 7.5 r4/4 none ms Os ml 9w na .7 .8 elev. 98.7 ft. 4 30-38 10yr5/4 c2p 7.5yr5/8 sil M na gw na np .2 Depth to 5 38-84 7.5ry4/4 none co s Osg ml na na .7 .8 limiting factor +84" Remarks: Boring # 1 0-8 10yr3/3 none 1 lcsbk mfr cs if .4 .5 2 8-16 7.5yr4/4 none sl lcsbk mfr gw if .4 .5 3 16-40 7.5yr4/4 none ms Osg ml gw na .7 .8 Ground elev. 4 40-48 10yr5/4 c2p 7.5yr5/8 sil M na gw na np .2 96. L ft. - 5 48-84 7.5yr4/6 none ms Osg ml na na .7 .8 Depth to - limiting factor +84" Remarks: Boring # 1 0-10 10yr3/3 none 1 lcsbk mfr gw if .4 .5 '....5..,<» 2 10-28 7.5yr4/4 none sl lcsbk mfr gw if .4 .5 3 28-40 7.5yr4/4 none ms Osg ml gw na .7 .8 Ground elev. 4 40-45 10yr5/4 c2p 7.5yr5/8 sil M na 9w na np .2 96.1 ft. 5 45-84 7.5yr4/6 none ms Osg ml na na .7 .8 Depth to limiting factor 8411 Remarks: Boring # OEM Ground elev. I ft. Depth to limiting factor Remarks: SBD 8330(8.05/92) f STEEL'S SOIL SERVICE Gary L. Steel David Waldroff 1554 200th Ave. CSTM2298 NW4SW4 S21-T30N-R18W New Richmond, WI 54017 MPRSW-3254 lot #3-csm (715) 246-6200 town of Richmond This soil evaluation was conducted to satisfy a zoning requirement, it may or may not be suitable for your use. The location of the test may or may not be as shown as permanent lot lines were not established at the time the test was conducted. N 111=top of 1" steel pipe by NE lot corner C el. 100.00' Alt. BM.= top of 1' steel pipe @ el. 93.00' -2- ~ 4q AC 6 ~a 5 ~ d 5 DIO boo Gary L. Steel 4-28-99 / 4 , i THIS INSTRUMENT DRAFTED BY MICHAEL ERICKSON JOB NM 99-43 DATEo 8/23/99 y a B IEAR NGS ARE REFERENCED TO -4 ~v d n r1 EAST - VEST 1/4 LINE OF SECTION 21. t ASSUMED -TO BEAR f 89'36-37-E S it 2. O " Xcr"l r+ tern to s o oil o -UNPLATT ED _ LANDS \ ti $ w X m OWNED BY PLATTER ~ry ~ o 500'04'54"W 698.03' Z -nA~ v ti W 'too VIDE ACCESS EASEMENT o zry 9 tid I H 500.04'54"V 68 ,A y 2384' OA 622.03' I D ro ►10 0 rz ► S00.04'54"W 572.14' l m~ 1. co ' •IININMNINII.INNNN.I.N.NIN.NIgNIN11NINNN•11(N•1 ' y..ININNN NNII.NNNINNN.•.•1•ININ 111 I \ -Ww _ N00 04'54N6 94 Y 1 \ N 00'04'54" E 428.63' w, its sum • .03 MOro4'54"E 1262.25• c ~112T EET EAST LINE W - THE NVt/4 OF THE SVIA e ♦ - ( , UNPLATTED LANDS oil, 09 ► Z A f OWNED_ BY_.OTHERS _ 6 ~OR SEA' ~ w~ 3 L.. V9103 Page 3717