HomeMy WebLinkAbout026-1160-14-000 (3)
Wisconsin Ct-partmeut of Commerce SOIL EVALUATION REPORT Page ofj
Division of Safety and Buildings
in accordance with Comm 85, Wis. Adm. Code
County -
Attach complete site plan on paper notless than 8 112 x 11 inches in size;. Plan must
include, but not limited to: vertical and horizontal reference point (BM), direction and Parcel I.D.
percent slope, scale or dimensions, north arrow, and location and distance to nearest road. (YPlease print all informati,Pn. Revie ed by Date
Personal information you provide may be used for secondary purposbs (Privacy Law, s. 15.04 (1) (m)).
Property Owner Property Location
Grp r Govt. Lot , 1 14 S t~3 T N R E( w
Property Owner's Mailing ~~77ddress Lot # Block # Subd. Name, or CSNt#
City state. Zip Code Phone Number ❑ city ❑ lllage 7/ own Nearest Road
New Construction Use: Residential / Number of bedrooms Code derived design flow rate GPD
❑ Replacement ❑ Publi or commercial - Describe:
Parent material -a A Flood Plain elevation if applicable ft-
General comments
and recommendations:
Boring r
Ul Boring # 13 it Ground surface elev.r" Qft. Depth to limiting factor in. Soil Application Rate
HHorizonDepth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/fg
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. yy~ •Eff#1 •Eff#2
67 VC,
Z Z~
3
Ground surface elect. " ' L) ft. Depth to limiting factor in.
Boring # ABP(i)tring
Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/fF
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. •Eff#1 'Eff#2
i 3Iz S 2 F ' S awe , 5 l
Z a'dZ 1(7 s/ C l l L w l L~
3 ZZ fj m 7
Effluent #1 = BOD > 30 < 220 mg1L and TSS >30 < ' Effluent #2 = BOD 130 mg/L and TSS < 30 nVL
CST Name (Please Print) Ignature CST Number
Bird Plumbing, Inc. Shaun Bird 226900
Address Date Evaluation Conducted Telephone Number
1008 192nd Ave, New Richmond, VJi?4'017 ' 715-246-4516
Property Owner _ Parcel ID # Page of
Boring # ❑ Boring
it Ground surface elev~~ aft. Depth to limiting factor in.
Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ff°
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. 'Eff#1 'Eff#2
~0 -ze Icy/ ;L
5JL C L 1 r, , s'b
❑ I(
Boring # Boring
F-1 ❑ Pit Ground surface elev. ft. Depth to limiting factor in.
Soil ~Eplicafion Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ff
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. 'Etf#1 'Eff#2
Boring # ❑ Boring i
❑ pit Ground surface elev. ft. Depth to limiting factor in.
Soil lication Rate
Horizon Depth Dominant Color Redox Description. Texture Structure Consistence Boundary Roots GPD/ff
in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. 'Eff#1 'Eff#2
Effluent #1 = BOD5 > 30 < 220 mg/L and TSS >30 < 150 mg/_ ` Effluent #2 = BODS < 30 mg/L and TSS < 30 mg/L
The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
need material in an alternate format, please contact the department at 608-266-3151 or TTY 608-264-8777.
SOD-8330 (8.6/00)
J
# William Soil Test Plot Plan
Project fVame am Stock/Steve Dalton Shaun
Address 1748 112th St.
New Richmond Wi 54017 C #226900
Lot 14 Subdivision Whitetail Meadows Date 8/15/03
S 1 /2 N W 1/4S 23 T 30 N/1318 W Township Richmond
Boring Well PL Property Line County ST. CROIX
BM or VRP Assume Elevation 100 ft. Top of 1/2" Pipe
System Elevation 97.3/97.2 *HRPSame as Benchmark
Alt. BM Top of 1/2" Pipe @ 100.2'
Please note: Installer must
verify all lot lines and setbacks
before installation.
Scale is 1" = 40'
unless otherwise
noted
Please Note: Tested area
may not be suitable for
desired building area.
~r Check system location
before excavating.
a
° Tested area has 0%
Slope and thus no
contours can be
established
B-1 B-3
493' Property Line Alt. B.M.
5
B.M. 35'
45'
B-2
45' 5' Pro Town
Road
50'
Xe~ ly
Bird Plumbing Inc.
1008 192nd Ave
New Richmond WI 54017
715-246-4516
Subject: Whitetail Meadows Soil Tests
To Whom it may concern:
I Shaun Bird did the soil tests on this subdivision known as Whitetail Meadows in
Richmond township. Aftbr a couple of installations, some of the soils were found to have a
more weak structure than what was found in some of the borings. In order to protect home
owners and contractors, it is my recommendation after discussing the issue with Pam Quinn
from St. Croix County Zoning office that the systems be oversized using a.3 loading rate
instead of the original .4 rate. On the lots that were originally sized for a .5, I recommend
using a.4, not the new.6 that the state has suggested. The soils are what the tests indicate
but the large areas tested did not reveal some of the weaker structures that were found
upon installations. If a installer can prove otherwise, that the weaker structures do not exist,
then the installer should proceed with the soils that he/she believes are present.
Shaun Bird
CST #226900
Z _ d ds4 = T T 40 sa add
4 ST. CROIX COUNTY
WISCONSIN
r '4 ZONING DEPARTMENT
r ST. CROIX COUNTY GOVERNMENT CENTER
"~,NNM~IINNN■ r~~Nli_
1101 Carmichael Road
0 M, Hudson, WI 54016-7710
Phone: (715) 386-4680 Fax (715) 386-4686
Memo to File
From: Pam Quinn
Date: 4/27/2004
Re: Sandy loam structure misinterpretation on subdivision soil reports
Recent soil on-site determinations have brought a problem to our attention. During these on-
sites, borings were exc vated to confirm soil conditions where two conflicting soil reports had
been submitted for zong department review. The soil profiles, evaluated by myself, Dave
Fogerty, and Dave Steel (all certified soil testers) differed from the original soil reports in that
massive (structureless) sandy loams were encountered in horizons that were described as having
either moderate, medium subangular blocky (2msbk) structure by Adam Schumaker or weak,
medium granular structure (lmgr) by Shaun Bird. There apparently has been a
misunderstanding between "structure" caused by handling samples of the soil during texturing
versus the soil characteristics in situ. The soil, when chunks were taken out of the profile to hand
texture, with pressure parted into "crumbs" that appeared at first to be subangular or granular in
shape. However, these were not true peds that broke apart along planes of weakness, but
fragments created by handling. The soil when observed in the horizon did not have distinct units
of structure and should have been reported as "massive".
Added notation: on 4/23/04 Mark Iverson (Cedar Corp. certified professional soil scientist),
Shaun Bird, and myself did an evaluation of soils on Lots 6 & 9, Richmond Meadows where the
original soil report described the third horizon as sandy loam, "l mgr". On Lot 6 we checked
soil profiles within a POWTS distribution cell and then excavated a test pit on Lot 9. The sandy
loams in question were a weak, coarse to very coarse subangular blocky structure, where planes
of weakness were just discernible when peds were parted from the profile. The peds separated
with very light pressure by soil tester. Sand coatings were observed on the ped faces in the Lot 9
soils, which supported the determination that some structure existed to allow water to move
through the upper portion of the sandy loam horizon. However, below the weak-structured soil
we found massive (structureless) sandy loams and the boundary between these horizons was
irregular, which would mean a distribution cell could encounter alternating weak and massive
sandy loam. Shaun said he would amend his soil reports with a memo recommending that any
sandy loams he identified as "lmgr" or "2 mgr" be assigned a lower loading rate of 0.3 gpd/ft2
(see attached memo for Whitetail Meadows) to provide a larger dispersal area.
Page Two - Soil Memo 4/27/04
Massive sandy loams have been assigned a soil application rate of 0.2 gpd/ft2 with the code
changes in Comm 83.44-2, effective as of 2/1/04. The application rates listed on the soil reports
were higher due to the structure having been described as either weak or moderate, which affects
the calculations for sizing of POWTS distribution cells. Obviously, one of the concerns is to
make sure loading rates for the soils are not in error and allow undersized POWTS to be
installed. For example, in December 2003, Lot 35 of Richmond Meadows subdivision had to
have its loading rate reduced to 0.3 gpd/sq. ft. when the installer encountered massive sandy
loam at the system elevation. The sandy loam horizon had been described on the soil report as
"I mgr" with firm consistence.
Leroy Jansky, Dept. of Commerce Regional Wastewater Specialist, has been consulted on this
situation and advised the zoning department to require on-site verifications for any lots with this
potential misinterpretation on the soil reports. All soil reports with sandy loam "1 or 2 mgr" as
its structure will be required to use a design based on the current code's soil application rate for
massive sandy loam @ 0.2 gpd/sq. ft. unless additional soil testing proves otherwise.
i
J
ST. C _ IX COUNTY
WISCONSIN
- ZONING OFFICE
~~~MrM/r■ - unr ST. CROIX COUNTY GOVERNMENT CENTER
1101 Carmichael Road
.w
Hudson, WI 54016-7710
(715) 386-4680,p Fax (715) 386-4686
June 16, 2004 File Ref: 10-04 -
Dal Stock, Inc.
1748 112`" Street
New Richmond, W154017
Re: Board of Adjustment Decision
Dear Applicant:
The St. Croix County Board of Adjustment has reviewed your request for a special exception
permit for five two-family dwellings in the Ag/Residential District and has approved this
application with conditions. The enclosed document is the formal decision regarding your
application.
Should you have any questions or concerns, please do not hesitate in contacting me.
Sincerely,
wag
Rod Eslinger
Interim Zoning Director
dz
Enclosure
cc: Donna Ray, Clerk, Town of Richmond, w/enclosure
Ty Dodge, JEO Consulting, w/enclosure
Pete Kling, LWCD, w/enclosure
i
I
FINDINGS, CONCLUSIONS, AND DECISION
OF THE ZONING BOARD OF ADJUSTMENT
ST. CROIX COUNTY, WISCONSIN
Case: 10-04
Applicant: Dal Stock, Inc.
Complete Application Received: March 15, 2004
Hearing Notice Publication: Weeks of April 5 and 12, 2004
Hearing Date: April 22, 2004
FINDINGS OF FACT AND CONCI USIONS OF LAW
Having heard all the testimony, considered the entire record herein, and conducted an on-site
inspection, the Board finds the following facts:
1. The owner of the property is Dal Stock, Inc., 1748 112th St., New Richmond, W154022.
2. The property is located in the Whitetail Meadows Subdivision, 146th Avenue, New
Richmond, WI, in the SW 1/4 of the NW 1/4, Section 23, T30N-R18W, Town of
Richmond, St.Croix County, Wisconsin.
3. An application was made for a special exception permit to construct one twinhome on each
lot (lots 12-16) of Whitetail Meadows, for a total of five twinhomes. The Board of
Adjustment finds that the requirements have been met to grant the special exception
pursuant to Section 17.15(6)(a) of the St. Croix County Zoning Ordinance.
4. The Town of Richmond has recommended approval of the request.
5. There was no opposition to the request.
6. The plans for the project have been designed by a professional company and will be
professionally installed.
7. The Land and Water Conservation Department has approved of the request with
recommendations stated in the conditions.
8. The Board finds that the location chosen in the subdivision is an appropriate place
for proposed twinhomes to be constructed.
9. The Board finds that the twinhomes will provide affordable housing to the residents of St.
Croix County.
10. The Board finds that the request is not contrary to the public interest.
11. The Board finds that the spirit and intent of the ordinance would be met by granting this
request.
DECISION
On the basis of the above Findings of Fact, Conclusions of Law, and the record herein, the Board
approved the request for a special exception permit for a two family dwelling in the
Ag/Residential District with the following conditions:
1. This permit allows the applicant to construct one twinhome (two family dwelling) on lots
12-16 of the Whitetail Meadows Subdivision. For any other use, the dwelling would
have to fully comply with the provisions of the St. Croix County Land Use Regulations.
2. The applicant shall demonstrate to the Zoning Office that each lot has an area sufficient to
accommodate for the Private Onsite Wastewater Treatment Systems (POWTS) serving
the structures before this permit is valid.
3. Applicant shall secure a sanitary permit for each structure from the Zoning Office and a
building permit prior to commencing construction.
4. The best management practices (silt fence) must be installed before commencing grading
activity (site preparation) for the project per recommendation from the Land and Water
Conservation Department.
5. In an e-mail dated April 5, 2004 from Pete Kling, the LWCD has reviewed and approved
the request with three comments. The applicant shall comply with the following
recommendations made by the Land and Water Conservation Department: 1)
Constructing the driveways all the way to the building pad would be ideal and provide an
even better construction entrance for the twinhome construction; 2)Require twinhome
construction to adhere to the Uniform Dwelling Code erosion control procedures
identified in Comm.. 21.125; 3) Additional erosion control maintenance. In addition to
the silt fence around the existing wetland, require twinhome builder to accept the
responsibility of maintaining and repairing existing erosion control practices (erosion mat
and temporary ditch checks) in the west road ditch from station 2+00 to 11+00.
6. Applicant to maintain at least 1.'/2 off street parking spaces for each family for which
accommodations are provided in the building plus one more space per building per
section 17.57 (2).
7. The property shall be kept in a neat and orderly manner. All outside storage of garbage
containers shall be screened and protected from rodents. No junk, junk cars or garbage
shall be allowed to accumulate on the property that may attract rodents or pose a threat to
the health, safety and welfare of those citizens of St. Croix County.
8. All driving and parking areas must be provided with a dust free surface
(asphalt/concrete/road millings, etc...). The applicant must submit a paving plan to the
Zoning Office prior to commencing this project.
9. Any proposed lighting is to be directed away from neighboring properties.
10. The Zoning office is to be notified at the start and the finish of the project.
11. The applicant must allow free and unlimited access to the project site at any reasonable
time to any Zoning Office employee to inspect the property for compliance with these
conditions.
12. Any change (or addition) in use, or expansion of the project, including building, signage,
shall require review and approval by the zoning administrator and in some circumstances
through the Special Exception approval process, where applicable, as stated in the
ordinance.
13. The applicant shall have one (1) year from the issuance of the special exception permit to
commence the construction. Failure to do so shall result in revocation of the special
exception permit. If the special exception permit expires before business commences, the
applicant will be required to secure a new special exception permit before starting or
completing the project.
14. These conditions may be amended or additional conditions may be added if unanticipated
conditions arise that would affect the health and/or safety of citizens or degrade the
natural resources of St. Croix County. Conditions will not be amended or added without
2
notice to the applicant and an opportunity for a hearing.
15. Accepting this decision means that the applicant has read, understands, and agrees to all
conditions of this decision.
The following vote was taken to approve: Peterson, yes; Marzolf, yes; Krueger, yes; Golz, yes;
Chairperson Speer, yes. Motion carried.
APPEAL RIGHTS
Any person aggrieved by this decision may file an appeal in St. Croix County circuit court within
30 days after the filing date shown below, pursuant to sec. 59.694(10), Wisconsin Statutes. St.
Croix County assumes no responsibility for action taken in reliance on this decision prior to the
expiration of the appeal period. St. Croix County does not certify that the identity of all persons
legally entitled to notice of the Board of Adjustment proceedings, which resulted in this decision,
was provided to the County.
If an appeal is taken of this decision, it is the responsibility of the appellant to submit at his/her
expense a transcript of the Board of Adjustment proceedings to the circuit court, which is available
from Northwestern Court Reporters, Hudson, Wisconsin. It is the responsibility of the Board of
Adjustment to submit its record (file) of this matter to the circuit court.
ZO G BOARD OF JUSTMENT
Signed:
Chairperson
'V 'ej
Attest: W
Date Filed: 06/16/04 Interim Zoning Director
I
3