Loading...
HomeMy WebLinkAbout030-2111-20-000 (2) Wisconsin Department of Industry, SOIL AND SITE EVALUATION REPORT Page 1 of 3 Labor and Human Relations Divrsion of Safety & Buildings in accord with ILHR 83.05, Wis. Adm. Code COUNTY Attach complete site plan on paper not less than 8 1/2 x 11 inches in size. Plan must include, but St. Croix not limited to vertical and horizontal reference point (BM), direction and % of slope, scale or PARCEL I.D. # / _ oZ 0 dimensioned, north arrow, and location and distance to nearest road. 030-`TO24 70- APPLICANT INFORMATION-PLEASE PRINT ALL INFORMATION R 15D BY DATE PROPERTY OWNER: l(~ PROPERTY LOCATION GOVT. LOT SW 1/4 SW 1/4,S 6 T 29 N R 19 or) W PROPERTY OWNERS MAILING ADDRESS LOT # BLOCK # SUBD. NAME OR CSM # 1129 30th. St. 14 na Deer Haven CITY STATE ZIP CODE PHONE NUMBER ❑CITY ❑VILLAGE FKffOWN NEAREST ROAD Hudson, WI. 54016 (715) 381-5264 St. Joseph 30th. St. jc] New Construction Use [x] Residential / Number of bedrooms 4 [ J Addition to existing building j J Replacement [ ] Public or commercial describe Code derived daily flow 600 gpd Recommended design loading rate .5 bed, gpd/ft2 .6 trench, gpd/ft2 Absorption area required 1200 bed, ft2 1000 trench, ft2 Maximum design loading rate • 5 bed, gpd/ft2 .6 trench, gpd/ft2 Recommended infiltration surface elevation(s) 92.00 ft (as referred to site plan benchmark) Additional design / site considerations trenches 3 5' below grade, spaced to ccdP Parent material outwash Flood plain elevation, if applicable na ft S = Suitable for system CONVENTIONAL MOUND IN-GROUND PRESSURE AT-GRADE SYSTEM IN FILL HOLDING TANK U = Unsuitable fors stem ® S ❑ U ® S ❑ U ® S ❑ U LR S ❑ U ❑ S CCU ❑ S r-411 SOIL DESCRIPTION REPORT Depth Dominant Color Mottles Texture Structure Consistence Bour>d~y Roots GPD/ft Boring # Horizon in. Munsell Qu. Sz. Cont. Color Gr. Sz. Sh. Bed Trench 1 0-12 10yr4/3 none sil 2msbk mfr CS 2f .5 .6 ,...._.1,.::" 2 12-32 10yr4/4 none sil lcsbk mfr gw if .2 .3 3 32-84 7.5yr4/4 none sl 2mgr ~ mvfr na na .5 .6 Ground elev. 95. ri ft. Depth to limiting factor 'VAW -t +8 Remarks: Boring # 1 10-8 10Y r3/3 none sil 2msbk mfr CS 2f .5 .6 2 2 8-16 10yr4/4 none sil lcsbk mfr gw Ground if .2 .3 3 116-27 7.5yr4/4 none sl lcsbk mfr gw na .4 .5 elev. 4 127-84 7.5yr4/4 none ms sOg mvfr 'c~ na` .7 .8 95.5 ft. ~ •ys Depth to limiting factor _ - = - +84" Remarks: ' G(JNryx CF CST Name:--Please Print Gary L. Steel Phone: 715-246-62 Address: 1554 200th. e. New Richmond, WI 54017 Signature: Date: 7-25-98 CST Number: m02298 :~:E ztk9 f] - PROPERTYOWNER DAniel C. Davis SOIL DESCRIPTION REPORT Page 2 of 3 PARCEL I.D. #Q3.0-1024-70 Boring # Horizon Depth Dominant Color Mottles Texture Structure Consistence Boundary Roots GPD/ft in. Munsell Qu. Sz. Cont Color Gr. Sz. Sh. Bed Trench 1 0-8 10 r3 3 none sil 2csbk Mfi CS 9f .5 .6 2 8-16 10yr5/4 none sit 1 csbk mfi gw if .2 .3 Ground 3 16-27 7.5ry4/4 none sl 2mgr mfr gw if .5 .6 elev. 93.6 ft 4 27-84 7.5yr4/6 none lfs Osg mvfr na na .5 .6 Depth to limiting factor +84" Remarks: Boring # 1 0-11 10yr3/3 none sil lcsbk mfi gw 2f .2 .3 4 2 11-18 7.5yr4/4 none sit lcsbk mfi gw if .2 .3 3 18-25 7.5yr4/4 none sl 2mgr mvfr gw na .5 .6 Ground elev. 4 25-50 7.5yr4/4 none 1 fs 2mgr mvfr gw na .5 .6 91.9 ft. 5 50-84 7.5yr4/6 none ms Osg mvfr na na .7 .8 Depth to limiting factor +84" Remarks: Boring # 1 0-12 10yr4/3 none sil 2msbk mfr gw 2f .5 .6 5 2 12-51 7.5yr4/4 none sl 2csbk mvfr gw if .5 .6 3 51-84 7.5yr4/4 none ms Osg mvfr na na .7 .8 Ground elev. 91.9ft. Depth to limiting factor +8411 Remarks: Boring # Ground elev. ft. Depth to limiting factor Remarks: SBD-8330(8.05/92) STEEL'S SOIL SERVICE Gary L. Steel 1554 200th Ave. CSTM2298 Daniel C. Davis New Richmond, WI 54017 MPRSW-3254 Sw4Sw4 S6-T29N-x19w (715) 246-6200 town of St. Joseph lot #14-Deer Haven This soil evaluation was conducted to satisfy a zoning requirement, it may or may not be suitable for your use. The location of the test may or may not be as shown as permanent lot lines were not established at the time the test was conducted. N 1"=40' BM.= nail in corner post C el. 100' 2• Alt. BM.= top of 2" pvc pipe @ el. 92.30' X90 Gary L. Steel 7-25-98 I`