Wisconsin Department of Commerce SOIL EVALUATION REPORT Page 1 of 3
Division of Safety and Buildings in accordance with Comm 85,W is.Adm.Code Tom Schmitt
Attach complete site plan on paper not less than 8%z x 11 inches in size. Plan Plan must St. Croce
include,but not limited to:vertical and horizontal reference pant(BM),direction and
percent slope,scale or dimensions,north arrow,and location and distance to nearest road. Parcel I.D. p
Please print all information.
Re
Personal information you provide my be" s.15.04(1)(m)). vi By Date 2F
Property Owner I Property Location
Grand Properties, LP Govt.Lot NW 1/4 NW 19 S 23 T 31 NR 19 W
Property Owners Mailing Address a 2 Z Q 04 Lot# Block# Subd.Name or CStYI#
712 Rivard Streeet,Suite 300 10 Gavin's Acres: First Addition
City S e Zifs GbchL<POwe)Wur�iber J City _j Village !M Town Nearest Road
Somerset ' PING F Somerset I 62Nd St.
iI New Construction Use: 6011 Residential/Number of bedrooms 3 Code derived design flow rate 450 GPD
Replacement Public or commercial-Describe:
Parent material OutWash Flood plain elevation,if applicable na
General comments
and recommendations: Area is suitable for a mound system. System elevation is 97.80'based off of contour line established at
96.95'. Slope is 1%.
Borng# I Boring
sm Pit Ground Surface elev. 96.67 ft. Depth to limiting factor 32 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/fF
'Eff#11 'Eff#2
1 0-10 10yr3/3 none Is 1csbk mvfr as 1f .7 1.6
2 10-32 10yr4/4 none Is 1csbk mvfr cs 1f .7 1.6
3 32-47 10yr5/4 old 5.5/1/8 s Osg ml es .7 1.6
4 47-74 1 Oyr4/6 c2d 5.5/2/8 gm Osg ml — — .7 1.6
Boring# I Boring
0 Pit Ground Surface elev. 97.71 ft. Depth to limiting factor 29 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ftz
'Eff#1 'Eff#2
1 0-8 10yr3/4 none is 1csbk mvfr as 1f .7 1.6
2 8-29 10yr4/4 none Is Osg ml gW 1f .7 1.6
3 29-70 10yr5/4 m3d 10vr6/6 Is Osg ml — — .7 1.6
10 /2
*Effluent#1 =BOD?30<220 mg/L and TSS>30<150 mg/L *Effluent#2=BODS<30 mg/L and TSS<30 mg/L
CST Name(Please Print) Signature: CST Number
Thomas J.Schmitt �� 227429
Address Tom Schmitt Date Evaluation Conducted Telephone Number
1595 72nd St.,New Richmond,WI 54017 420/04 715-247-2941
Properly Owner Grand Properties, LP Parcel ID# Page 2 of 3
3]F Boring# J Boring
Pit Ground Surface elev. 96.58 ft. Depth to limiting factor 26 in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots
*Eff#1 *Eff#2
1 0-11 10yr3/3 none sl 2msbk mvfr as 1f .6 1.0
2 11-26 10yr4/4 none Is 1msbk mvfr gw — .7 1.6
3 26-44 10yr4/6 c210yr /8 Is 1 msbk mvfr gw — .7 1.6
4 44-72 10yr5/4 c2d 10yr6/8 9rs Osg ml — —
F—I Boring# — Boring I Pit Ground Surface elev. ft. Depth to limiting factor in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD
*Eff#1 *Eff#2
F-I Boring# J Pit Boring
Ground Surface elev. ft. Depth to limiting factor in. Soil Application Rate
Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots QP
*Eff#1 *Eff#2
Effluent#1=BOD?30<220 mg/L and TSS>30<150 mg/L *Effluent#2=BOD5<30 mg/L and TSS<30 mg/L
The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or
need material in an alternate format,please contact the department at 608-266-3151 or TTY 608-264-8777.
,PV d
Page 3 of 3
h
Conducted by: Conducted for:
Schmitt Soil& Site Evaluations Name: Grand Properties,LP
Thomas J. Schmitt,CST 227429 Address: 712 Rivard St. Suite 100
1595 72nd St. City, State,Zip: Somerset,WI 54027
New Richmond, WI 54017
715247.2941 Subd.Name: Gavin's Acres,First Addition
Phone: .
Lot No. ZP
1/4,NGJ I/4, S23,T31N,R19W
Township of Somerset
BM El. 100.00'
Alternate BM El.2 , S-
Slope=_,t2% Contour Line El.
N
Scale: I"=40'
111 tis' 31 68
0
l,k�
83 is- uNn,s 96.�s-
q��,A7u,2g�./J
94
i
(&4PLJ 5�)
�3$
This soil report was done to fulfill a Zoning requirement.It may or may not be in a location that is