Loading...
HomeMy WebLinkAbout040-1322-10-000 (2) 2 SOIL EVALUATION REPORT Jam---+ #1980 Department of Commerce in accordance with Comm 85,Wis.Adm.Code Page 1 of 3 Division of Safety and Buildings Steel's Soil Service Attach complete site plan on paper not less than 8'/Z County x 11 inches in size. Plan must St. Croix include,but not limited to:vertical and horizontal reference point(BM),direction and percent slope,scale or dimensions,north arrow,and location and distance to nearest road. Parcel I.D. Ing �L— (J V Please print all information. Revi ed By Dat Personal information you provide may be or MppEE9lPrivacy aw,s.15.04(1)(m)). �a ! Property Owner ll VV�–�L+J Property Location Tom And Renee Patnode Govt.Lot na NW4, SE-1/4, S19,T28N, R19W Property Owner's Mailing Address Lot# Block# Subd.Name or CSM# 225 Cty Rd F 10 na Troy Overlook City State ip C �- 1 ❑ City ❑Village -/ Town Nearest Road Hudson WI Troy Cty Rd F ❑]New Construction Use: ❑ Residential/Number of bedrooms 4 Code derived design flow rate 600 GPD ❑ Replacement ❑ Public or commercial-Describe: na Parent material Limestone uplands covered by glacial till Flood plain elevation,if applicable na ft. General comments Mound design, system elevation 101.41 ft based on contour line elevation 100.00ft. Minimuum 17 inches and recommendations: of ASTM33 mound sand. --y g ❑ Boring 1 Boring# ❑ Pit Ground surface elev. 100.00 ft. Depth to limiting factor 28 �in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ftZ in. Munsell Qu.Sz.Cont.Color Gr.Sz.Sh. 'Eff#1 'Eff#2 1 0-10 10yr3/1 none sil 2msbk mfr cs 1c .6 .8 2 10-28 7.5yr4/4 none sicl 2msbk mfr cs na .4 .6 3 28- 10yr7/4 none =racturec Limestone na na na .0 .0 Fi-1 ❑ Boring Boring# ,/ pit Ground surface elev. 100.00 ft. Depth to limiting factor 23 in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ftZ in. Munsell Qu.Sz.Cont.Color Gr.Sz.Sh. •Eff#1 •Eff#2 1 0-10 10yr3/1 none sil 2msbk mfr cs 1vf .6 .8 2 10-23 7.5yr4/4 none sicl 2msbk mfr cs na .4 .6 3 23- 10yr7/4 none zractureci Limestone na na na .0 .0 *Effluent#1 =BOD5>30<220 mg/L and TSS>30<150 L 'Effluent#2=BOD5<W mg/L and TSS<30 mg/L CST Name(Please Print) ❑ Signatur . CST Number David J. Steel ` ° 248956 Address Steel's Soil Service Date Evaluation Conducted Telephone Number 994 200th St.Baldwin,WI 54002 10/3/2006 715-760-0347 SBD-8330(R.07/00) Property owner Tom And Renee Patnode Parcel ID# pending Page 2 of 3 Boring# ❑ Boring ,/ ❑ Pit Ground surface elev. 99.20 ft. Depth to limiting factor 25 in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2 in. Munsell Qu.Sz.Cont.Color Gr.Sz.Sh. *Eff#t *Eff#2 1 0-11 10yr3/1 none sil 2msbk mfr cs ivf .6 .8 2 11-25 7.5yr4/4 none sicl 2msbk mfr cs na .4 .6 3 25- 10yr7/4 none =racture( Limestone na na na .0 .0 F-1 Boring# E] Boring ❑ Pit Ground surface elev. ft. Depth to limiting factor in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft' in. Munsell Qu.Sz.Cont.Color Gr.Sz.Sh. *Eff#f *Eff#2 F-1 Boring# ❑ Boring ❑ Pit Ground surface elev. ft. Depth to limiting factor in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/ft2 in. Munsell Qu.Sz.Cont.Color Gr.Sz.Sh. *Eff#t *Eff#2 *Effluent#1 =BODS>30<220 mg/L and TSS>30<150 mg/L *Effluent#2=BODS<30 mg/L and TSS<30 mg/L The Department of Commerce is an equal opportunity service provider and employer. If you need assistance to access services or need material in an alternate format,please contact the department at 608-266-3151 or TTY 608-264-8777. SBD-8330(R.07/00) Steel's Soil Service STEEL'S SOIL SERVICE 3 of 3 David J. Steel Tom & Renee Patnode 994200 th St. CST-POWTSM NW1/4,SE1/4,S19,T28N,x19w Baldwin, WI 54002 Lic. #248956 Town of Troy, St Croix Co. Direct 715-760-0347 Troy Overlook, Lot 10 Fax 715-684-3449 This soil evaluation was conducted to satisfy a zoning requirement,it may or may not be suitable for your use. The location of this test may or may not be as shown,as permanent lot lines were not established at the time the soil test was conducted. Legend N 1"=40' =Benchmark Ele. 100.00 ft Top of 3/4"pvc pipe • =Alt Benchmark Ele. 100.00 ft Top of 3/4"pvc pipe ❑ =Borings Boring Elevations BI = 100.00 ft B2= 100.00 ft B3 = 99.20 ft B4= 0.00 ft rl /r I t 3 l � . zONED: AGRI ULTURAL NORTH LINE OF THE NW 4 OF THE SE S 89'22'18" ,1 8x54' , i -_ IN, w N 00'47'3$" E 2.41 ------- --- -- - - c66.00' w 90 - - � 14 ' ABLEi— o' D 264_ .18' ° •?O• `� I i �_ _ ---- I I � I LOT 13 �s I — J ' / i d•Ac f )/ 1 2,94 WAN 22 _ 1 6 \ L0T 1 tf � .3 ' LOT �. v �. co \ _ ^ , �- � \ A \ \ Sao I 0. o � \ \ d / ) - I d � i LOT 10 \ w \ \� � � �� i l l LOT —I ao r J � 1 -66 z iY Ln 00 - 188.80- - ----- 79.04' a-D EAST 267.84' 3 Cop 93 EAST 267.84' ,-y ,,/ --- -------- ---------- --- 19.17 -,; 85.71 ----- 162.95' - i-� �' _ \ �o D -s� z z 126 JYVV 11 I ? i O r to J / L- ao ~mil I G ONSERVAnON - \E E r LOT - `— I � N•� r' i i