HomeMy WebLinkAbout040-1254-20-000 (2) Wisconsin Department of Commerce SOIL AND SITE EVALUATION Page 1 of 3
Division of Safety and Buildings in accord with Comm 83.05,Wis, Adm. Code
Environmental By Design
Attach complete site plan on paper not less then-81!s x 11 inches in size. Plan must County
include,but not limited to:vertical and hgriz6nW1 reference point(BM),direction and St._Croix
percent slope,scale or dimensions, i�arrow,and location and distance to nearest road. parcel LD.#
,•, 0-/2 - 2a-�
APPLICANT INFORMA ? Pleat alp!infdxmation. Rev' ed B _Date a -7 Ora
Personal information you provide m ' sed for (Privacy.Law,s.15.04(�)(►n))• L26
a?
Owner
Property Location
A ` _ Govt.Lot - SE 1/4 NW 1/4 S 19 T 28 N,R 19 W
Property Owners Mailing Add ss�. Lot# Block# Subd.Name or CSM#
�;,vrr
12301 Central Avenue E cite 2 t0E 92 - Troy Village Second Addition
City ate: Zip ode Phon b` ❑City ❑Village ❑Town Nearest Road Z '�
Minneapolis F Troy St.Andrews Drive l
New Construction Use: Resl en a /Number of bedrooms 4 ❑Addition to existing building
❑ Replacement ❑ Public or commercial describe
Code Derived daily flow 600 gpd Recommended design loading rate .7 bed,gpd/fta .8 trench,gpd/ft2
Absorption area required 857 bed,ftz 750 trench,ft' Maximum design loading rate .7 bed,gpd/f!2 .8 trench,gpd/ff
Recommended infiltration surface elevation(s) i (as refer�red to site plan be chmar
Additional design/site considerations �� 1�4`1�'
Parent material Loess Over Glacial Outwash Flood plain elevation,if applicable NA ft
S=Suitable for system Conventional Mound In-Ground Pressure AT-Grade System in Fill Holding Tank
U=Unsuitable for system ®S ❑ u ® S ❑U ® S ❑ U ® s ❑ U EIS ® u ❑ S ® u
SOIL DESCRIPTION REPORT
Depth Dominant Color Mottles Structure GPD/ft2
Boring# Horizon in. Munsell Qu.Sz.Cont Color Texture Gr.Sz.Sh. Consistence Boundary Roo Bed Trench
1 1 0-16 10yr2/1 - sit 2msbk mfr cw if
2 16-38 10yr4/4 - sil 2msbk mfr cw if 5 6
Ground 3 38-50 7.5yr4/6 - cs osg ml cvvv - .7 ! .8
elev
100.96 ft 4 50-110 7.5yr5/4 - s osg ml - - .7 .8
Depth to
limiting
factor
>110
Remarks:
2 1 0-16 10yr2/1 - sil 2msbk mfr cw if .5 .6
2 16-41 10yr4/4 - sil 2msbk mfr cw 1 f .5 .6
Ground 3 41-53 7.5yr4/6 - cs osg ml cw - 7 8
elev
100.62 ft 4 53-110 7.SYR5/4 - S OSG ML - - .7 ! .8
Depth to
limiting
factor
>110
I I I I I L-7
Remarks:
CST Name(Please Print) Sig a Telephone No.
Thomas C.Nelson
Address Environmental By Design Date CST Number Ref#
1432 120th Street,New Richmond,Wl 54017 1/30/98 M02605 5
PROPERTY OWNER:continental Develot>ment SOIL DESCRIPTION REPORT Page 2 0 3
PARCEL I.D.# Environmental By Design
Depth Dominant Color Mottles Structure GPD11
Horizon in Munsell Qu.Sz.Cont.Color Texture Gr.Sz.Sh. onsistence Boundary Roots
Bed ! Trench
3 1 0-16 10yr2/1 - sil 2msbk mfr Cw if .5 .6
2 1646 10yr4/4 - sil 2msbk mfr Cw if .5 .6
Ground
elev 3 46-58 7.5yr4/6 - s osg ml Cw - •7 .8
100.68 ft 4 58-110 7.5YR5/4 - s osg ml - - 7 8
Depth to
limiting
factor
>110
Remarks:
4 1 0-13 10yr2/1 - sil 2msbk mfr rcw w if .5 .6
2 13-45 10yr4/4 - sil 2msbk mfr w if .5 .6
Ground
elev 3 45-55 7.5yr4/6 - Cs osg ml - •7 •8
100.85 ft 4 55-110 7.5YR5/4 - s osg ml - - 7 .8
Depth to
limiting
factor `
_ 11_0 I
Remarks:
5 1 0-11 10yr2/1 - sil 2msbk mfr Cw if .5 .6
2 1141 10yr4/4 - sil 2msbk mfr Cw if .5 .6
Ground Gro
Gro 3 41-55 7.5yr4/6 - Cs osg ml Cw - 7 ; .8
100.4 ft 4 55-110 7.5YR5/4 I s osg ml - - •7 .8
Depth to
limiting
factor
>110"
Remarks:
6 1 0-15 10yr2/1 - sil 2msbk mfr Cw if .5 .6
2 15-43 10yr4/4 - sil 2msbk mfr Cw if .5 .6
Ground
elev 3 43-52 7.5yr4/6 - Cs osg m1 Cw - .7 .8
100.66 ft 4 52-110 7.5YR5/4 - s osg ml - - .7 .8
Depth to
limiting
factor
_ >110
Remarks:
1��II;ONMENTOL BY DE51GN
1432 1201h STREET, NEW RICHMOND, WISCONSIN
715-246-2454
PROJECT NAME: TROY VILLAGE 2nd ADDITION
DESCRIPTION: SEV,, NW1,, SECTION 19,,T 28 N, R19W
TOWNSHIP: TROY COUNTY: ST.CROIX
LOT: 92 SUBDIVISION: TROY VILLAGE 2RI ADDITION
scAu 1"=40' Tom Nelson
BM i NaH in tree elev. 100' cstmo2605
BM 2 SE Lot Corner Ground Surface elev. 95.16