Loading...
HomeMy WebLinkAbout040-1257-90-000 (2) Safety and Buildings Division 13 East Spruce Street Chippewa Falls,WI 54729 ww•�v.commerce.state.wi.us Tommy G.Thompson,Governor D}epartme w of Comm ercm Brenda J.Blanchard,Secretary February 28, 2000 a TTN: INSPECTOR CUST ID No..263197 ,�r < :- ENVIRONMENTAL BY DESIGN ST.',CROIX COUNTY ZONING 1101 CARMICHAEL RD THOMAS C. NELSON HUDSON WI 54016 1432 120TH STREET NEW RICHMOND, WI 54017 s RE: CONDITIONAL CERTIFICA''tON ''��,c aria Identification Numbers r' Site I.D. Number: na SITE ST CROIX COUNTY,TOWN ,Yf Transaction No.: 21862-901 NW 114,SE 114, S24,T28N, R20W Please refer to both identification LOT 112 -TROY VILLAGE THIRD ADDITION numbers, above, in all correspondence with the agency. DESCRIPTION: MOUND RESTRICTION RELEASE The Department has reviewed the additional information received on February 28, 2000, and the request to release the mound restriction on the above referenced property. This request is supported with information that indicates this property is acceptable for development with a below grade soil absorption type private sewage system. Therefore, the Department waives the above mentioned restriction and has no objection to the development of this property provided that the private sewage system is constructed in accordance with the applicable requirements of Chapter Comm 83,Wisconsin Administrative Code. Conditional certification is hereby made to waive the mound system restriction for this lot provided the following condition(s)are met: 1. The release and waiver of the mound restriction should be incorporated into a correction instrument under s. 236.295, Wis. Stats. This recommendation will eliminate future questions regarding the restriction on the recorded plat. 2. The soil absorption system areas on this lot are preplanned, and as such no development shall occur in the preplanned areas and development adjacent to the preplanned area shall meet appropriate setbacks so as not to jeopardize the private sewage system installation. Pursuant to Com 87.04 (7) (a)2.,Wis. Adm. Code, any changes to the location or extent of the preplanned area will require Department review and approval. This certification does not include review of the design for the proposed private sewage system. All other applicable criteria, as contained in chapter Comm 83, Wisconsin Administrative Code, must be met prior to issuance of the sanitary permit for a project at this site. All permits required by the city, village, township or county shall be obtained prior to installation. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sincerely, DATE RECEIVED 9/3/99 FEE REQUIRED $ 80.00 L roy G ansky, astew r Specialist FEE RECEIVED $ 80.00 Field Op rations Bureau BALANCE DUE $ 0.00 (715)726-2549 Fax (715)726-2544 Voice Ijansky @commerce.state.wi.us cc: DOA Plat Review St. Croix County Zoning WexonsinrDepartmentofCommerce SOIL AND SITE EVALUATION Page 1 of 3 Divisrfn of Safety and Buildings in accord with Comm 83.05,Wis.Adm. Code Environmental By Design Attach complete site plan on paper not less than 8'/x 11 inches in size. Plan must County include,but not knited to:,vertical and horizontal reference point(BM),direction and St. Croix percent slope,scale or d'irhemsions,north arrow,and location and distance to nearest road. Parcel I.D.# a67�0�G8 APPLICANT INFORMATION- Please print all information. Reba By Date Personal information You provide may be used for secondary purP�(PAY�.s.15.04(1)(m)). /\r Property Owner Property Location Continental Development Govt Lot NW 1/4 SE 1/4 S 24 T 28 N,R 20 W Property Owner's Mailing Address Lot# Block# Subd.Name or CSM# 12301 Central Avenue NE, Suite 230 112 Troy Village 3Rd Addition Ci(y State Zip Code PhoneNumber ❑City ❑Village ®Town Nearest Road Minn lis MN 55434 612-757-7568 Troy I St.Armes Parkway ❑ New Construction Use: ❑ Residential/Number of bedrooms 4 ❑Addition tD existing building ❑ Replacement ❑ Public or commercial describe Code Derived daily flow 600 gpd Recommended design loading rate 5 bed,gpdr 6 trench,gpdff Absorption area required 1200 bed,fF 1000 trench,fl? Maximum design loading rate •5 bed,gpd/ff .6 trench,gpd/ftz Recommended infiltration surface elevation(s) 94.75' -k" S43&m=I# ft(as referred lo site plan benchmar Additional design/site considerations Systems to meet minimum depth requirements Parent material Loess Over Glacial OutWash Flood lain elevation,if applicable NA ft S=Suitable for system Conventional Mound In-Ground Pressure AT-Grade System in Fill Holding Tank U=Unsuitable for system ®S ❑ u ® S ❑u I ® S ❑u ❑ s M U ® S ❑ u ❑ S M U SOIL DESCRIPTION REPORT Depth Dominant Color Mottles Texture Structure Consistent Boundary Roots GPD/f� Boring# Horizon in Munsell Qu.Sz.Cont.Color Gr.Sz.Sh. :B:ed ; Trench 1 1 0-13 10yr3/1 - sil 2msbk mfr cw 2f 5 i 6 2 13-37 10yr4/4 - sil 2msbk mfr cw if .5 i .6 Ground 3 37-49 7.5yr4/6 - Is 2msbk mvfr cw - 7 ? .8 elev 100.39 It 4 49-112 7.5yr6/4 s* Osg ml ,.. - - .7 .8 Depth to V v\ limiting .fig �� i.'�e'!tE l factor >112 Remarks: *w/bands of s 1 4/4 = /' t-101 X Ph,,.UN 2 1 0-16 10yr3/1 - sil rrfs mfr cw 2f 5 .6 W1�4. cvv if .5 .6 2 16-40 10yr4/4 - sit 2ms Ground 3 4046 7.5yr 4/6 - is 2msbk mvfr cw - 7 ? 8 elev 99.14 It 4 46--112 7.Syr6/4 - s Osg ml - - .7 .8 Depth to limiting factor >112 Remarks: CST Name(Please Print) Signature: Telephone No. Thomas C.Nelson 715-246-2454 Address Environmental By Design Date CST Number Ref# 1432 120th Street,New Richmond,WI 54017 / ' 227387 I20 PROPERTY OWNER:Continental Development SOIL DESCRIPTION REPORT �2 Page 2 of 3 Environmental By Desi PARCE,.I.D.# GPD/Ie Depth Dominant Color Mottles Texture Sere �onsistence Boundary Roots Horizon in Munsell Qu.Sz.Cont Color Gr.Sz.Sh. Bed ' Trench 3 1 0-10 10yr3/2 - sil 2msbk mfr cw 2f 5 6 2 10-30 10yr2/1 - sit 2msbk mfr cw if 5 6 Ground - .5 ; .6 elev 3 30-52 10yr4/4 - sit 2msbk mfr cw 99.64 ft 4 52-57 l Oyr4/4 - is 2msbk mvfr cw - .7 .8 Depth to 5 57-138 7.5yr6/6 - s Osg m 8 l 7 limiting factor >138 Remarks: 4 1 0-12 1Oyr3/2 - sil 2msbk mfr cw 2f .5 .6 2 12-31 10yr2/1 - sil 2msbk mfr cw if .5 ? .6 Ground - 5 6 elev 3 31-42 10yr3/4 - sil 2msbk mfr cw 100.98 it 4 42-61 10yr4/4 - sil 2msbk mfr cw - .5 .6 Depth to 5 61-70 10yr4/4 - is 2msbk mvfr cw - .7 .8 limiting factor 6 70-85 7.Syr6/4 - s* Osg ml cw - .7 .8 >102 r,4o 7 85-02 7.5yr4/6 n - s Osg I ml - - .7 i .8 Remarks: *bands of sand 10yr4/4 5 1 0-17 10yr3/2 - A 2msbk mfr cw 2f 5 6 2 elev 3 17-35 10yr4/4 35-47 7.5yr4/6 - sit 2msbk mfr cw if .5 .6 Ground is 2msbk mvfr cw - 7 8 - 99.96 ft 4 47-1 4 7.5yr6/4 - s Osg ml - - 7 8 Depth to limiting factor >94" Remarks: Oe e4 Ground elev Depth to limiting factor Remarks: ST. CROIX COUNTY WISCONSIN .� ZONING OFFICE N ST.CROIX COUNTY GOVERNMENT CENTER ■rr:r 1101 Carmichael Road Hudson, WI 54016-7710 (715) 386-4680 September 15, 1999 Wisconsin Department of Commerce Plat Review ATTN: Leroy Jansky Box 8911 Madison,WI 53708-8911 RE: Onsite soil verification, lot 23, 27-28, 60-61, 64 112 of Troy Village Subdivision, Sec. 19, Town of Troy, St. Croix County,Wisconsin Dear Leroy: I have reviewed the soil reports for lots 23, 27-28, 60-61, 64 and 112 in Troy Village Subdivision, filed by Tom Nelson, CSTM #227387 and have conducted onsite soil verifications on these lots. My findings have verified that the soil conditions as reported by Mr. Nelson are accurately described. The soils on these lots are suitable for subsurface sewage disposal with loading rates of 0.5/0.6 and 0.7/0.8 GPD/sq.ft. I'm also concerned that a large portion of the tested area on lots 23, 27-29 and 112, was disturbed due to the fact that the borings got quite large during excavation and were open for such a long time. Specifically, I'm concerned that when these borings are back filled, some of the subsoil will mix with the coarser soils, thus affecting the infiltration rate. If you have any questions regarding this issue, please contact me at the number listed above. Sincerely, )pd 66—� Rod Eslinger Zoning Specialist cc: Chuck Cook, Continental Development Corporation Tom Nelson File Safety and Buildings Division Field Operations Bureau - 13 East Spruce Street �/'� Chippewa Falls,WI 54729 ISconsiI1 Tommy G.Thompson,Governor Department of Commerce ��r`• Brenda J.Blanchard,Secretary October 16, 1999 CUST ID No. 263197 ATTN INSPECTOR ZONING OFFICE ENVIRONMENTAL BY DESIGN v, --rCk , ST CROIX COUNTY 1432 120TH STREET ,` ✓' 1101 CARMICHAEL RD NEW RICHMOND WI 54017 / HUDSON WI 54016 Identification Numbers SITE ST CROIX COUNTY,TOWN OF TROY NW 1/4, SE 1/4, S24,T28N, R20W Transaction No.: 21862-901 LOT 112 -TROY VILLAGE THIRD ADDITION Please refer to the appropriate DESCRIPTION: MOUND RESTRICTION RELEASE identification numbers, above, in all correspondence with the agency. The Department has reviewed the request to release the mound restriction on the above referenced property. The approval of this proposal is being put on hold until additional supporting information is received: 1. Deeper soil boring data for B-4 and 5 or revised soil absorption system installation elevations based on the limits of the soil depth and suitability data. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. Sinc rely, DATE RECEIVED 09/27/99 FEE REQUIRED $ 80.00 FEE RECEIVED $ 80.00 eroy G. ansky, astew a Specialist BALANCE DUE $ 0.00 Field Operations Bureau (715)726-2549 Fax (715)726-2544 Voice Ijansky @commerce.state.wi.us cc: Continental Development DOA Plat Review Wisxunsin Department ofCommerce SOIL AND SITE EVAL UATION Page 1 of 3 Division of Safety and Buildings in accord with Comm 83,05;d/1fis Adm. Code k. Environmental By Design Attach complete site plan on paper not less than 8%x 11 inches in size. Plan mom:' R County include,but not limited to:vertical and horizontal reference point(BM),direction Eki2t��' St. Croix percent slope,scale or dimensions,north arrow,and location and distance M ?#e t road Parcel I.D. APPLICANT INFORMATION- Please print all information. S1`t 1 Rev' y Die / q Personal information you ovide may be used for seaondar r (Privacy Law,s-15. m ` �} r w r r purposes t r l� t 3) Property Owner Pro iNGCY=F=GE ° Continental Development Govt f'';"; NW 1/4 /4 S 24 T 28 N,R 20 W Property Owner's Mailing Address Lot# I 1%5jtime or CSM# 12301 Central Avenue NE Suite 230 112 1 `°�i- Tro Vill e City State Zip Code PhoneNumber ❑City ❑Village ®Town Nearest Road Mitut • olis iViN 55434 612-757-7568 Troy Luidsay Road New Construction Use: ❑ Residential/Number of bedrooms 4 ❑Addition to existing building Replacement ❑ Public or commercial describe Code Derived daily flow 600 gpd Recommended design loading rate 1.2 bed,gpdifl? 1.2 trench,gpd, Absorption area required 500 bed,W 500 trench,fF Maximum design loading rate 1.2 bed,gpd/tf 1.2 trench,gpd/ftz Recommended infiltration surface elevations) 91.51 It(as referred to sfie plan benchmar Additional design/site considerations Thick"A"horizon due to colluvial deposits at the base of hill tParent material Loes s over Bed Rock Flood lain elevation,if licable na ft ble for system Conventional Mound In-Ground Pressure AT-Grade System in FBI Holding Tank itable for system ❑S ® u ® S ❑u I ❑ S E I ❑ S ® u I ❑ S ® U I ❑ S ® u SOIL DESCRIPTION REPORT Horizon Depth Dominant Color Mottles Texture Structure Consistence Boundary Rants GPU/fl? Boring# in, Munsell Qu.Sz.Cont Color Gr.Sz,Sh. Bed ; Trench 1 1 0-24 1Oyr4/2 - sil 2msbk mfr cw 2f .5 i .6 2 24-34 10yr3/2 - sil 2msbk mfr cw if .5 ! .6 Ground 3 34-64 10yr4/4 - sil 2msbk mfr 5 6 elev 89.63 ft 4 64-68 10yr8/3 - BEDRX - - - - hjP ! N o Depth to limiting factor 64 Remarks: 2 i 0-9 10yr3/3 - sil 2msbk mfr cw 2f .5 .6 2 9-32 10vr4/6 - sil 2msbk mfr ew if .5 .6 Ground 3 32-36 10yr8/3 - BEDRX elev 88.64 ft Depth to limiting factor 32" Remarks: CST Name(Please Print) Signature: Telephone No. Thomas C.Nelson 715-246-2454 Address Environmental BY Desiglt Date CST Number Ref# 1432 120th Street,New Richmond,Wl 54017 12/30/98 227387 81 . PROPERTY OWNER:Continental Development SOIL DESCRIPTION REPORT ® Page 2 of 3 PARCEL t.D.tr Environmental By Design • Horizon Depth I Dominant Color Mofdes I Texture I Structure �Consisten Boundary( Roots I GPD/il� in. Munsell Qu.Sz.Cont Color Gr.Sz.Sh. I Bed ! Trench 1 0-21 10yr3/2 - sil 2msbk mfr cw 2f .5 .6 2 21-31 10yr5/3 - sil 2msbk mfr cw If .5 .6 I Urouna elev 3 31-35 10yr8/3 - BEDRX - - - - Nf' NO '56.76 ft Depth to limiting factor 31'g Remarks: Ground I iutry r r r , I I I I t Depth to limiting factor I Remarks: Q mU! l I I I I I I ,..,« .n.. r r t r I I r r I elev Depth to )imifing factor Remarks: r r r r I Ground elev Depth to limiting factor , , I r I I I I Remarks: ENVIgONMENTHL BY DE51GN 14321201h STREET, NEW RICHMOND, WISCONSIN 715-246-2454 TT?nV BBT Tl?I TT V11 .1 .A P E ISO i; L 3 NW% SE Y, SECTION 24 T 28 N. R 20 W TOWNSHIP TROY COUNTY St. Croix, Wisconsin ` lad 113 36 -7 LA o � 3 Aj I N ` N o i3S 7f° S o PQ Q3 !fib 23� .gC' i LJ � ( ( a�► SCALE 1" =40 Tom Nelson BM 1. SW LOT CORNER Ton of iron pine ELEV. 100' 227387 BM 2. SE LOT CORNER OF LOT 113 TOP OF HUB ELEV. 91.92' 02/26/21DOO 14:33 7152462801 TOM NELSON - RECEIVED OIL AND SITE EVALUATION DW=n of and lMNKP in accord with COMM$3_05,Wis,Adm.Code FEB 2.8 2000 ArUK a compiete SO plan on paper rwir less man M x 1 kom'n . Plan ny'4* . riot§miedit:Vertical acrd t>oritordat ve*enm POW(OM),dtredm and S 8 BLDG&OW:L w. i $rcerh sue,=2!e OF*nwn aro.nxat aCroe r,snfl and dtawm to =rep mad. pwmi Fa APPUC W INFOR11ilAWN- Pie prhtt all wo"Moon. 8-1 parsrx A irj.m you► p W9 rrvv be used f+w sarxrdP wn ( Y Low,w i6.04(1)Oro- _ - Pmp"LowtM3.1 P Govt. :: y:; -^ 4v �v r mw ua �>w �a � � prpprp tamper a laA�lirtg AddYes6 Lot# BiOCI(# Subd.WaM Or CSM# _ a 12301 Central Avenue. Su 10 230 �leereat ROB� City State 71p Cade PhoneNumber n CRY Town 1vTN 5SA34 i51�-7�7-75b8 T'1°y W t e,n !N[ �tOri l �ASldgrlli e t r D�bedtooix�� 4 L,lA n t)e)ds* xatar p►ag -� Cade lwved J ttD9, 600- _.�Qtd r4e(xxnm9nded deagn i ng .S aeg .S A� €mod 12 bed, `jga tmnch,is AMMwM d%Qn 2d m raa bad,WIV t 3G: RsaWmmK d ln*'a aon su fiW elevdor4S) 94-75' It(as retrred b :may A.d�lion�D 9t11 slh!ca�rins�°p�n�oivaum deptb ns��ts _ -.__ Parent.'medal €mss Over Glacial thdwash Hood ' Cerlin� �t ir}�rs►�rlR�# AT-Q r► t .w�°,%T Esau 0aousCtug ® � cj U u-munsuAabe for system solL WSCPJP110H REPORT Bcdftg s lzs�n FlunseA Qu Ccllpr Tactual;i GY Sz Sfi. ;onssrt Boats ► ; , 6 t :3 10yT311 r77r 2 i 13-37 10yrV4 - st1 2msblr cgfr m x , Gmnd 3 37-49 7.5yr416 - s is 2rmsbl _xnvfr : r elm w %Us f<f 4 49-17.2'° 7.5yr6/4 w s ml - -8 >112 w/bands of s J!bcW4 ------- 3 } 046 10ya/1 - t 2n Ground 3 40-46 7,5yr 416 is w 2msbk ms✓ :a _ 1 99.14 ft ? 4 �46-.11 7.5yW4 - s +• 0sg 'nl _ _-- _ s cap o CST Nww(p4we Prt ��• T '� 3►Cra�z; .Addra&s Eve lay llesrg}r " 4rsn >r D43212ftS0Vet,T40w)?j W1 54017 4 f G'!w�-2i3t;9 �2/28/2030 14:33 7152482801 T CJtyi NELSON 3 C: a> �oremcaowi� __ SOL DESCRIPTION REPORT 2 .� + � 1 Texl�u�e ii _ . munseil Qu.Sz.cont cow a _ II 0-10 10yr3/2 2 1 142-30 10yr?!I - 2k -- (a�lMilly mf-. 9.9.84;t ; j3• 52-5'1 tl )t?yr414 _ Is mrrxr���_-- __ .•° _ d J __.. ,1 5 -15 7-138 @ 0•12 10yr3/2 - — zai 2n0* 3 h A,�vS L l0yt'1/d 9 { { Z1I15�f�C 1 42 i±ms's IS .7r� ?�.ltib � �..Sr I' �".�r —' •�C' II --- iC09$t' 1"4 - 2Msb t 6 70-85 7.5yW4 - 3� 3 ow, A -7 33-1 i{U 7.5ypWG oui d 11 q -.•vi ttbt 1 bm&of swd LOyW4 ' a 0.17 )Oyfrl2 2 i'-35 9 [Oyr414 - r1 2 'I _ h 35-47 7.5yr4/6 � - 1 �s � ZmsSk k nevi V-140 — CE r 1 00 I SAFETY $ BLDGS DIV. [RVIROKAER7AL �Y OfSf*�R 1432 '120`t' STREET,NEW RICHMOND, WISCONSIN 715-246-2454 Tom Nelson Certified Soil Tester 227387--Registered Sanitarian SR00713 ***s*ss**s»*sss*ssssss*s*ss*s*s***********sss*ssss*s*ss***s**ss*s I IV 110 c�� e 1y b5 o SCAU 1 _ Toni Nelson BM I. -To Q n-C Sto(z-m cl ca' r-, Co c\ �A v BM 2 7a P o F r-, i i L-J/ Yet) o..-) 9�;66o h q S , I ENVI*PONA 1'�K 1432 120`b STREET, NEW RICHMOND, WISCONSIN 715-246-2454 Tom Nelson Certified Soil Tester 227387--Registered Samtarim SR00713 ( i e `' "sc 11 L. c h s Ip N o I. a 2.3�.�� ' SCALE 1" = ?C) Tom Nelson BMl—Fo� BM 2 G t Ua c.1 10 CJ r-1 6 C''� n Aggregate SAS SYSTEM ELEVATION AND SIZING CALCULATIONS Below Grade Aggregate Soil Absorption Systems Lot 112 Permit Number 2/28/00 Date X X. Gravity Distribution only 1 Pressure Distribution 3 ft Suitable Soil 1 8 in Aggregate Depth 2 4 lin Nominal Pipe Diameter 600 gpd Estimated Daily Peak Flow 0.80 gpd/ft 2 Wastewater Infiltration Rate 750.0 ft Minimum SAS Size 94.75 Ift Proposed SAS Elevation Soil Surface Acceptable Finished Grade EL 3(ft) Boring Grade Limitation SAS Elevation(ft) System Minimum Maximum Number Elevation(ft) Depth(in) Lowest I Highest Elevation? 97.42 99.25 1 100.39 112 94.06 98.72 Yes Cut required 2 99.14 112 92.81 97.47 1 Yes 3 99.64 138 91.14 97.97 Yes Cut required 4 100.98 140 92.31 99.31 Yes Cut required 5 99.96 140 91.29 98.29 Yes Cut required 1. Depth of suitable soil required below the infiltrative surface for treatment. 2. Depth of aggregate below distribution pipe. 3. Based on chosen system elevation,and aggregate depth. The addition of fill for cover or the reduction of finished grade may be required to meet minimum or maximum code standards. Personal information you provide may be used for secondary purposes[Privacy Law,s.15.04(1)(m)]. SBD-10553-E (R.05/98) L Troy ueveidpnranf CbrMraNbizi 1�?J111 Central Avenue AE Blaine, MN 55434 (612) 757-7568 OMOT 3 COMMON AREA — PARK 4.�AC 4 9.405 ACRES M 0 1223 AC s4885 1 AC LEGEND A° 1.64?C UTILITY EASEMENT. 10' WIDE o•7i 9 I ——— UNLESS OTHERWISE SHOWN. ?� _............. DRAINAGE EASEMENT, 10' WIDE ,,' 41 42J �- 2 47 UNLESS OTHERWISE SHOWN. 1.617 AC a t.ioe c 48 49 N BUILDING SETBACK LINE. 75' 1.642 AC N �9 4 064 A 7.5?7 PC — — — UNLESS OTHERWISE SHOWN. J �•�' 2% <• I/ 129,3C '*^ 1.013 /k ;ir ♦ 39 �'' 2 3.310 AC < 2 31 n 34 g m,.000 AI 1.491• 1.038 Ace 2.2 GOLF COUR .23 240.00 G 1004 ALT y� 35 1 ,.026 AC B�M�'1.�0 � .i3T <Z _N ,ryN,i "i 2.36• 1 I < ' 2449 AC 38 ''IR. N Z4°.°ol I 2.508 AC .- 1 04 AC 29 M45'N,259.051 �y _�.� 7.313 C I''�•22' /qI/ J, N 24 ,.0 0 Ac 6' 7 .y ?'a / ' 1,bos OUTLOT 12 N e t. 7 Acb �`%' 28 " ': •. COMMON AREA— N^,16403 c � 1238 A PARK ' ti o 1 0 I 9.044 AC ti� da s S, ?x'2015 C� �,- , 1.1575 C, y,. 102 1 ? 1.340 AC n. 106 try• ",� �* / S• 3a0.61. A./ / Ti�.20 AC �i0 1 /.7 ro 5 .`� '' °S'' ^� 11 1.694`6AC ro^' U 1.290 107 •�o; x,1.000 C. �� I I ti°" 5 101 1.300 AC n,01' �`Pa ♦ 6e p"i• 1.5'w A tat N 2103 AC iy53• ^ro1�1.025 3 317.71' 108 �J9, ♦ n� 7 385 AC ^� ° 100 0p' i �� ti ,o e 2Ac 7.1 a 5c 20 N 1.911 (109 lea 9 1.048 Ac 300.61 i 1 591 AC, 6 6 99 ,.�el Ao o GOLF COAJ ,e �?07.401 ACS ti 11 �� l• rl;�: 00 C ,.3e17A � Id 2.7607AC m 0 20 ` 98 NC 1.006 AC ••''. io 1.425 AC P_ ^i 1.004 9 A �3 8 11$ ''•.. ti 1.632 AC j•..� �tJ J 6 v4