Loading...
HomeMy WebLinkAbout030-2121-80-000 Wisconsin Department of Commerce PRIVATE SEWAGE SYSTEM County: St. Croix Safety and Building Division INSPECTION REPORT Sanitary Permit No: GENERAL INFORMATION (ATTACH TO PERMIT) 592169 Personal information you provide may be used for secondary purposes [Privacy Law, s.15.04 (1)(m)j. State Plan ID No: 2782253 Permit Holder's Name: City Village Township Parcel Tax No: McCormack Classic Construction TOWN OF SAINT JOSEPH 030-2121-80-000 CST BM Elev: Insp. BM Elev: BM Description. Section/Town/Range/Map No: 1106-1.0 1M 6iGrT 30.30.19.990 TANK INFORMATION ELEVATION DATA TYPE MANUFACTURER CAPACITY STATION S HI FS ELEV. • o I67. / /a a . / Septic ` Benchmark dAl /600 . *j Dosing Alt. BM D a Bldg. Sewer Holding q- 9Z. t Inlet ~O TANK SETBACK INFORMATION St/Ht Outlet TANK TO P/ t WELL BLDG. V it intake ROAD Dt Inlet Septic ZZ ' Dt Bottom Dosing d ZZ f Header/Man. Y s3 /bz. 2.5 Aeration Dist. Pipe 73/6 z, z Holding Bot. System 8B Al. 3 Final Grade O PUMP/SIPHON INFORMATION 3 /10 Z Manufacturer zOe Demand St Cover I GPM 19 - 1/ 15 Model Number /51 7 24 d ' `t5. z o . 8 /aa .3 TDH Liftt Friction Loss 0, Head TDHI Forcemain Length Dia Dist. to Well SOIL ABSORPTION SYSTEM BED/TRENCH Width Length No. Of,Zrench r IT DIMENSIONS No. Of Pits Inside Dia. Liquid Depth CV i DIMENSIONS, Jj P_ SETBACK SYSTEM TO P/L BLDG f WELL LAKE/STREAM LEACHING Manufacturer: INFORMATION Type O/~S~tem: /Q 1_7 73 CHAMBER OR Y'a J UNIT Model Number: DISTRIBUTION SYST M Lb454.,. Header/Manifol Distribution T 0 Hole Size x Hole Spacin V Air Int Pipe(s) 1 Length Dia / - 67 IL ength Dia Spacing ' SOIL COVER x Pressure Systems Only xx Mound Or At-Grade Systems Only 'W Depth Over / Depth Over xx Depth of 1XX Seeded/Sodded xx Mulched Bed/Trench Center 1 Bed/Trench Edges Topsoil , J/~. `1 '°'S No Yes No COMMENTS: (Include code discrepencies, persons present, etc.) Inspection #1: Inspection #2: Location: 376 132ND AVE ^ On` / .•TTJ~ / 1.) Alt BM Description ~OJ'«• l ` Pf O i~ 2.) Bldg sewer length= -amount of cover = / ;7 1 46 v-.- eL P/4 ('i Plan revision Required? ❑ Yes <No L_ 5 Use other side for additional information. . SBD-6710 (R.3/97) Date Insepct s Signatu Cert. No. I~ECEIV'EC~ - - et 't , , J ~tirU ?aJ~ 1 OCT J 20 16 ftulustn S C'ou,1;, QS I #f?0 i 41,~shin tun~ve $ i' rl E3o~ ~ S ST. CROIX COUNTY 16-2 j Sanltan Pcmit NumbL (ta a: '_i h~- Co.) - uD1V1MUNITY DEVELOPMENT iuladisOll X153,70i 12 Sanitary Permit Applicat1eq, '~~F p ' tc'I'ratisactu,n ysrnher- aceordance with SPS 383?1(3), Wis- Adm Code, submission of this ; it n ~j$ ~j~ ~J '3 cyuin l prior to ohtauuag a saaitan permit ,vote. Aophcatial Corms for ua c u„neu [ t t n - De!lartment of Safety and t rot~seu,na! Service,. Persona! information oral you Provide p. m Qp O_ie t Address ~l.? dt,;eiem than mad addtessl - .ores it, accordance with j! 'e Pn,acear, s_ I5U-1{ OEm'} Stays _ 74 _ ~PPhc ttion Information mezse Print ll Information. 3a ,fin roperty Owners Name - f F - - tsars. G~c ssie ~aA)SrIZue- rio.~ " L 9 3~IJ4I- w if ens OWner's Mailing Address - ----_j-------- _ p Propene t o catio , State- A r Go, Lot I Zin C:odc~ - ['hone Number - ~ ~ - fs, SE Section _ %PfiitLsa,) 1S 7(.O " I circle on ~ e'. ti. T'ti•pe of Building check all that apply) N_ EZ~ fit' ,9I or'-- Family Ucscl-it;6 -1`'unihcroi Bedrooms 3 ` i Suhdir-ision h ne t3!oe! 6~ 4D yNE" c 7u44 y ` ❑ Pubhe(Commert,iai Describe Lise ' o t L StateO3sned/DescribeUyr CS!,1\mnher - E.ir}n~rt o, r , : , ~Sr ,%asEP,N III. l jpc of Permit; {Checfi 01 111 one bos on line .Complete line B it'apptfcxbie} - - - - - Vre3r System I L Rep!ar~n3ent System ❑ Treatmentlliolding Tan[; Re lacer Only I p ❑ Other vlod:iicat,on to FsiStine System (explain) B. I Permit Renewal C Li Pennit Re; ision. List Pre, loos Permit \utnber and Datc 1s Chanac of 1 lumber Permit Tratas.er to tic, s;uto Before Expiration 1 Os,mcr i _ tl 'hype of PO\t'"I_S STstemfC2!! onentfDcrtcc (Check all that ably,) - - ❑ Non-Pressurized In-Ground 0 Pressurized In-(,round 1 At-Grade Mound . it,. et ,mtab!e soil Mound ,n. o, :unsnle sei! - - -LL I-loldin~ Tank ❑ Other Dispersal Component 7 Pretrwtmcnt D, ice (explain) _ i• V. Dis ersalti'reat ent ,_ca Information: DeSlgn Flow (Upd} ! Design Soil Application a[c(spdsf) I Dispersal .Area Rec!ttir stl 1 Dis at Area Pr , y;ed ( C _ pers ~ Lon. Go„lTOV4. VI. Tank In o + /D t cirr~ P Total = Of Nlanulitcturei Gallons 1 Gallons ( Units Ke«Tanks ti~isunc'1'auk, f Y - ' J - _ - I ~ 1 ~ , l t f y t l j000 Do t Chatn[>cr . 1 _Gs~frrrs~2 ~O~J C4d !'E Gad - 400 rt - - 1' I I Responsibility Statement- h the undersigned, assume responsibility for installation or the POD` TS shmi n on the attached plans- Pltunbers iName {Prnril Plumber` i atuic 4IR Number Bus ness Phone Number - ~I an -/,0.aE~,eF w ,?3/3yC 17is G72 -S.7[G 'lumber's Address {Street, Cm ;State Iii? Code) - = - / Go? 98 SSr_ rrr a?S Z- Sy C IJ - VIII, County/Department Use Oniy J0. Pcnnii i=cc Date sued Issuing Signlh, k ! .3;.71 ,Ot De/l.al r frS. - f ondit„dfb~r :ti Ceflrm`ustittlltoer{Sappro~a! t Jl~ ~a , asons 'lt as per management PI um*. VI&AOW Q u,. a , /K4s e..~ 2. All setback reuulreme mt; .t at2Gitiid r as per applicable c0r~ m , 4 ~~e~Yl . attach to complete plans for dye system and sut,mtt to if., Cnnnt,' ont, on pattern i Joey then s 7r_- x 1 inches in size Cep : wee.. ,tom wj urM: S33I}-6398 (R. 08114) 5 tt`` S a LX 6 paj Ax- 4 r.J. 0 - a a V y i nti ~ M sus ~t ti \ ' o try . ~ ` 4u 4 9C ~ 3 o h / "t- Ilk Q o Q v a y 3 o f v Z e NO lz t x i~kY ART -~rOX DIVISION OF INDUSTRY SERVICES 2331 SAN LUIS PL STE 150 'i GREEN BAY WI 54304-5211 Contact Through Relay http //dsps.wi.gov/programs/industry-services www.wisconsin.gov ?ol Scott Walker, Governor Dave Ross, Secretary CONDIT L October 06, 2016 APP 7 , DEPT OF CUSTIDNo. 231346 AT"TN: PO WTS Inspector PROFESS10 JOHN HERBERT PELKE DIVl4t t'r's`a:3 ZONING OFFICE PELKE PLUMBING ST CROIX COUNTY SPIA N6298 ST HWY 25 110 1 CARMICHAEL, RD DURAND WI 54736 HUDSON WI 54016-7708 SEE CC-'! CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 10/06/2018 Identification Numbers Transaction ID No. 2782253 SITE: Site ID No. 829512 McCormack Classic Construction Please refer to both identification numbers, 132ND Ave above, in all correspondence with the agency. Town of Saint Joseph St Croix County NWI/4, SE1/4, S30, T30N, R19W FOR: Description: EZ-Flow YVlound (3 Bedrooms - New Construction) Object Type: POWLS Component Manual Regulated Object ID No.: 1626936 Maintenance required; 450 GPD Flow rate; 24 in Soil minimum depth to limiting factor from original orade; System(s): EZflow Mound Component Manual, (R. 7/12), Pressure Distribution Component Manual - Ver. 2.0, SBD- 10706-P (N.01/01, R. 10/12); Effluent Filter 'The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. 'The submittal has been CONDITIONALLY APPROVED, "This system is to be constructed. and located in accordance with the enclosed approved plans and with any component manual(s) referenced above. The owner, as defined in chapter 101.OI(10), Wisconsin Statutes, is responsible for compliance with all code requirements. No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06, stats. The following conditions shall be met during construction or installation and prior to occupancy or use: • Preserve dispersal area prior and during construction to avoid disturbance, compaction and use of the site. • With new construction; it is recommended not to activate the pump in the dose tank until the tanks are pumped prior to homeowner occupancy. • Wastewater generated from contractors cleaning of equipment and tools and/or left over construction products shall not be discharged into the drains discharging to the private onsite wastewater treatment system (POWTS). Waste generated shall be properly disposed of on-site or off site. • Any tall grasses, leaves and shrubs shall be cut short and removed prior to tilling the surface for installation to prevent matting under the dispersal area. All loose organic material to be removed from POWTS dispersal area. • Prior to construction of the dispersal area, check the moisture content of the soil to a depth of 8 inches. Smearing and compacting of wet soil will result in reducing the infiltration capacity of the soil. Proper soil moisture content can be determined by rolling a soil sample between the hands. If it rolls into a 1/4- inch wire, the site is too wet to prepare. If it crumbles, site preparation can proceed. If the site is too wet to prepare, do not proceed until it dries, JOHN HERBERT PELKF Paee 2 10/6/2016 The distribution pipe being inserted into the 4" corrugated pipe located in the EZflow product shall have one out of every five orifices installed at the 6 o'clock position. The remaining four orifices shall be installed at the 12 o'clock position. The laterals shall drain fully after every dose. The lateral turn-up ends shall extend out past the exterior end of the cells at both ends. "The observation pipes shall be located in between where bundles come together. These requirements must. be followed so that the aggregate bundles will not be damaged during the installation process • Divert surface water from POWTS Area. • All piping shall conform to SPS Table 384.30-3 and SPS Table 38430-5 • Insulate building sewer beyond 30 feet per SPS 38230 (11)(c) • Tank Installation to follow all manufacture's recommendations. • Well setbacks to meet chs. NR 811 & 812 • Verify property line(s) prior to installation. Pump Floats to be set and verified per approvedIrtn. rOnv c la tai<~es may result in pump resizina to meet TDH and GPNM Specifications. 'This system is to be constructed and located in accordance with the approved plans and with the "Pressure Distribution Component Manual for Private Onsite Wastewater 'Treatment Systems Version 2.0" SBD-10706-P (N.01/0 1). • This system is to be constructed and located in accordance with the approved plans, and the "EZflow Mound Component Manual " (R.7/12). • Areas that are occupied with rock fragments, tree roots. stumps and boulders reduce the amount of soil available for proper treatment. If no other site is available, trees in the basal area of the mound must be cut off at furound level. A laraQr fill area is nccessar,, when any ofthe above COrlditio r!S are encountered, to provide sufficient infiltrative area. Owner Responsibilities • "The current owner, and each subsequent owner, shall receive a copy ofthis letter including instructions relating to proper use and maintenance of the system. Owners shall receive a copy of the appropriate operation and maintenance manual and/or owner's manual for the POW TS described in this approval SPS 383.54(1). A copy of the approved plans, specifications and this letter shall be on-site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/installation/operation. In granting this approval the Division of Industry Services reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101,12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. 'The above left addressee shall provide a copy of this letter and the POWTS management plan to the owner and any others who are responsible for the installation, operation or maintenance of the POWTS. JOHN HERBERT PELKE Page 2 10/6/2016 • The distribution pipe being inserted into the 4" corrugated pipe located in the EZflow product shall have one out of every five orifices installed at the 6 o'clock position. The remaining four orifices shall be installed at the 12 o'clock position. The laterals shall drain fully after every dose. • The lateral turn-up ends shall extend out past the exterior end of the cells at both ends. The observation pipes shall be located in between where bundles come together. These requirements must be followed so that the aggregate bundles will not be damaged during the installation process • Divert surface water from POWTS Area. • All piping shall conform to SPS Table 384.30-3 and SPS Table 384.30-5 • Insulate building sewer beyond 30 feet per SPS 382.30 (11)(c) • Tank Installation to follow all manufacture's recommendations. • Well setbacks to meet chs. NR 811 & 812 • Verify property line(s) prior to installation. • Pump Floats to be set and verified Der approved plan Any changes may result in pump resizing to meet TDH and GPM Specifications. • This system is to be constructed and located in accordance with the approved plans and with the "Pressure Distribution Component Manual for Private Onsite Wastewater Treatment Systems Version 2.0" SBD-10706-P (N.01/01). • This system is to be constructed and located in accordance with the approved plans, and the "EZflow Mound Component Manual " (R.7/12). • Areas that are occupied with rock fragments, tree roots, stumps and boulders reduce the amount of soil available for proper treatment. If no other site is available, trees in the basal area of the mound must be cutoff at ground level. A larger fill area is necessary when any of the above conditions are encountered, to provide sufficient infiltrative area. Owner Responsibilities • The current owner, and each subsequent owner, shall receive a copy of this letter including instructions relating to proper use and maintenance of the system. Owners shall receive a copy of the appropriate operation and maintenance manual and/or owner's manual for the POWTS described in this apps oval SPS 383.54(1). A copy of the approved plans, specifications and this letter shall be on-site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. All permits required by the state or the local municipality shall be obtained prior to commencement of c onstruction/installation/operation. In granting this approval the Division of Industry Services reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. The above left addressee shall provide a copy of this letter and the POWTS management plan to the owner and any others who are responsible for the installation, operation or maintenance of the POWTS. JOHN HERBERT PELKE P, ue 3 10/6/1016 Sincerely, Fee Required $ 250.00 Fee Received 250.00 Gae,~ Balance Due 0.00 Tim Vander L,eest Private Sewage Plan Reviewer 9 Division of Industry Services WiSMART code: 7633 (920)492-2214 , Monday - Friday 6 am To 3:30 pm ti~~l.vanderleestu~viscc3nsin,tio~ ~I ln~ anhd- e '`age ()ed Name= / riQ.YA c rc C~~ A.ssrc ~a n+~ r~u c rso,~ 3 , / eavime s Name: !j to Jr t" 4 LY olumees ?rs 7GQ - as//; igm , agy e fir; .I a Bloom N z:. Parm! LD. Page 2 Pap 3 L OHO Jd. ? •4 s O`,; t~/ ' ° G r is les 'Page 4 ~ ,t ~ ~'~r~p!"L r✓ „sjt~~ Lr1idY~`' .f~iY"d"~4~r ~ G. /~~J s~G ~Ot3r.1 ~?r~~"LS". Page ? P%ae i rs C.~! diJr GJStl/.sSS e' l . !ro/i L~ Out (A r~ Ji tl R2 3d r Pap dL .F"'~C ~J't~O2d"9i5~i 1daJ &-4,fA Dam: Desiped POT gmed . s`~'fx G!✓s ?'~l u_}} ro sa - a ~ . .sa s~ ' it~r~r~ fJ'x a rc,Fr fir? ~ 1 ,~~~8~-rte ~faa' eol 6 0 a ~ V ~ ~ y l `Y ~ d h r ~ V'. k+f ~ ice[ ~ ` I o 3 V ~ Q ~ elf IZI k4jw V Y- 'It VIS, a t• 0 0 h v iy'? ~ r f a t, N4 M me , I -Z ~1 ~ - Cda bps ~ - ~ ~ ..rt ` ~ t~ . 51 17 8 _ a 4J y rt1 "~.•°1[ •t .~''i 1 a'te` ry 9 ~f. ~'aE"S ~ x 'dal h : t F k.S t M t °z~-:. n„i a.{d ~ V\~ ~ d Tat r { - - y 1 - _wk: _ F.,,aa '~~+"•,~°°°`'}✓`~Yl M! c 't i~~, 41 FA3 if :t yet! V r~ r1it F{E G ®.ad . ~+a t°g f , T~ {r s a Na a>^ a o ~-s - a a a o a -tf' i 42 A-1 t\ ~ f !~-Sa 5~ m 03 is .i Q l~ e $ j w R Eu ~i a 0 w w ~ ti it k 0 :1 is ' w RAY Iz- 12, ura aC pv Z ti v i:- ~ ~ c V3 '-tee" vy C.. ~ e 43 is 43 t 5~-i4 U) t Q m N P-4 V2 m :H G Q' F~J C fo a r CO ~flSllti+ 101\1 SEPTIC T Ai IiQPUMP CHAMBER I --CTj0j\1 9 :`RAVE ING NOT i 0 SCALE) - - MANHOLE RISERCO:COVER EWA GRADE - (slope ground surface -away from {psi S: ~S 3 84.25 [-f) sr a, {idip~R i Atli i s -VS Vent ,9 i:l3iin018(S~ IOr_L'r002idE$Srt$,C~.'8~ f _ _ }i47F? y as nac e'_sa-, j zT2? .t s Pursuant tss SPS 3a3.--'.3(~}(g} l - lr j r<t=ri~?nom ~itod ~~v~e:i i /rr I _P0:2d 3ulLClNG SEWER adend..tsnrm3s rm- s ~ ff t r t ! {pSf $2.30 (11)) _L=C T RIGt _ D~~vad La Arta i en ei_ f t JuiqCi7*oi3 sox n `s ! "(h ti{<rtirt~ :at rslaw.s i i I I i 1 {Tgri>~11 F f t it:diCaI rat cmrmiv t;L7. L ! SPS 376 c»d N--SO ! ! 4 _ 14 45l$QI{.t115Li ^ D+._ ,t.°.eiiD'~ 3 tI MANHOLz Mir, 90= iQi. U ii.LE C1 s CFiatenl 1 ~ {cr~fr^t2LrFi':c1]_.._ 1 _"fN~ 1 r°~lffr/.r.,.-r~ilfflJ/iJi`rr'>ri or,] 'rrlrlf%:rrrr~Y-~~ ~ ~ { ~v. , i'~ljffr/f!/f/lllltlrrOJj/I//fJJA l'r~ll',%/11.f{~ +rti<f Y - 1 { ~ _)rl/J/I1If.'/„~ 4c J//i'il./%.s ~//lrfr'/!r//'~ t'"! I i~fjf/1/lfr~ a Ca; ; ~1Jlft~llJ ' {IJJJII,.~ iK { ! •~'~illtrfJ/!/'•Uffi~!!l//!r//IIjfJ~~YjJfJ/J.r f!/' = 1 I Iflllilr/!I/l. ~l'T'«~~lt lliliGil i. i!1 'i rifslRsFLOP, ? ONVL6fii Flt T ERE s1i 3 L- - fise Drft.3+0i.9) a??!ROVE{,1FUL-iter"r1Ll,ER iililNIMIIUiv OF ZY OF SUIT LE BEEDDIKG Uhl= RAD I 3`aeltli«anl~aciur=r G~/6.SE~ Co.Je.i r DWI (daiiy-wasteufaipri[o~-1 i Seo:iclPuma talk model 1,00014 CO Number of daily dose: .S: y 'Yle !Ct'1E I actual nose ,=olwrnal lafisli ailufar.2 re 5, yc _ fstd.~113wS Alarm model Ru mber Ti9r9t!< f~L ~rcT ~ Corr aural YrnlLlrn JS //o tX .14 3 l'r+i i208t St IiIG!? /~G'~ v~ t rd G ':c?f;8 as vOtU1??6 I1oF?S (10fal dose 1,01 me - aliuma o forcemai3j /d p• L ` = Ba G Effluent l=ni1p 1od21 ililtill~E? Uivip T PINK CFst'f•'iCr1! IES asar,le abode alarm .?4 incr)Ie. = 33L-Nallol}a e- f Alarii iioat above on fioat ~ ir?F~ii2S = .3.3 iallonS (Cj ! itdiillinum oun, P discharcle rare _GPMi) ODIM fort measuymeni G. 0 incbas = 2, !j Canons iBl Veliica4 lift (pump Off to disiribult on lateral) q 3 Off loat above iani: bottom It. huhas = 1311 I gallons (R) .Z 5" SySierit Read (distat pressure n 13 feeti, J- 3- TANK DIMENSIONS `PUMP GHAi0M5'F SPECIFICATIONS ricJon ioss in the Toacemain. Ao x Q/y A, Mai dynarnic head DH) / g✓ ~ .^cZCS13 /San I'~tidtn ~y I Undo' tlCf}i(`i 3.1 t,alloq;w Dal Il?Cr 74 I zl u~w TOTAL DYNAMIC HEADIFLOW PUMP PERFORMANCE CURVE PER MINUTE MODEL 151/152.1153 EFFLUENT AND DEWATERING 5D- 1 I i 45_ a5 t t - MODEL j 151 152 153 F_ee 2fe{ GaS, Liters Gal. Lsr rs 1 Gal. i Aers• - - ' ---r i- _ 4q 35 62 - - - _ $ E',' 89 c9_ 26 71 _ i 411 ' 0 " G 3Q 45 70 61 i 231 70 265 4.6 38 -,44 53- 1 21' j 61 231- 20 6.. 29 ! 170 3% 167 52 197 r i f I 5 ~ _ C, 15 29 A2 199 2 9" i j 2"s 87 33 1 5 30.7 22 1 85 C J %e.2 11 I 2 - Snuk r1i Head, 39 fL 381_ (I t.arn) - 1 44 ft. t13.4in1 1C.. 0145085 i Model 151 Models 1521153 n 40 0 7 a„ 91 Xr." G A; _ LO%S - r < -r r- FLO', d '"JGTc - _ I ,•,-rap i • Timed dosing panels available. Electrical alternators, for duplex systems, are available and supplied with an alarm. • Variable level control switches are available for controlling single phase systems. i / - • Double piggyback variable level float switches are available for variable level long and short cycle controls. • Sealed Qwik-Box available for outdoor installations. See _ t F1U1420. = - - - Over 130°F (54'C) special quotation required. -T s. x 4151 ;7 l 15111521153 MODELS Control Selection Model Volts -ph triode Amps Simplex Duplex N151 1115 1 Non 60 1 20 31 BN151 115 - Auto 6.0 included 2 or 3 E 51 230 1 Non 3 1 2 ar 3 BE 51 230 1 Auto 3.2 Included 2 rn 3 "Easy assembly" N152 115 1 Ncn E.5 1 - a ' ipUTM, & discharge p;pe 13N152its Auto ' 8.5 Included i 2a-3 -E Y- 152 2 _ B 15Z ` 2 1 Noy r- a 3 i of 3 h- 30 1 Auto f 4.3 included 2 or 3 N153 115 1 Non 10's 1 2 or 3 BN153 i 115 1 Auto 10.5 included v or 3 f _ } E 53 23^v 1 Neon 5.3 1 2 or 3 Std . 1 BE153 230 Auto 3 included 2 w 3 t ~ r 1. Single piggyback variable level float switch or double piggyback variable level Refer to FM~t77. Reduces potential clogging by debris. float switch. Ref Replaces rocks bricks 2. See FM0712 for correct model of Electrical Ailemalor E-Pak. Made of durable, under the pump. , noncorrosive ABS. 3. Variable level control sxiich 10-0743 used as a control activator, specfiv duplex Raises pump 2" off bottom of basin. (3) or (4) stoat system. Provides the ability to raise intake by adding sections of 11/2" or 2" PVC piping. La CAUTION Attaches securely to pump. Accommodates sump. dewatering and effluent applications. NOTE: Puke sure float is free from obstruction. For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump. O Copyright 2008 Zoeller Co. All rights reserved.