HomeMy WebLinkAbout161-1060-70-000 Wisconsin Department of Commerce PRIVATE SEWAGE SYSTEM County: St. Croix Safety and Building Division INSPECTION REPORT Sanitary Permit No: (ATTACH TO PERMIT) 5173- 1 GENERAL INFORMATION State Plan ID No: Personal information you provide may be used for secondary purposes [Privacy La 4 (1)(m , Pe` ' Holder's Name City Vill Parcel Tax No: ~h ~ CST BM Elev: Insp. M Elev: BM Description: Section/Town/Range/Map No: ll ; 4 -.1 , '17.%Il " ~2,'I- TANK INFORMATION ELEVATION DATA TYPE MANUFACTURER CAPACITY STATION BS HI FS ELEV. Septic Benchmark g Alt. BM 16d 7 .Y >y l ~O c.p Ow A°• i Bldg. Sewer r ~ e Inn.Q_ .ts~-r Holding St/Ht Inlet f St/Ht Outlet V~ TANK SETBACK INFORMATION S (p.4 r17 TANK TO P/L WELL BLDG. Vent to r Intake ROAD QIRiet° 9-7- by o r4-. uj 7`$ 14 '57 t 14100 a . $ 1 T -77 Dosing Header/Man. _ _ ~.~.llfo 017~~3 Aeration Dist. Pipe 7/ E 7• r Holding Bot. System I to Final Grade PUMP/SIPHON INFORMATION Manufacturer D GPM emand St Cover 1~ r Model Number _ - `T' Va 40 T Lift Friction Loss System He TDH Ftu b Forcemain ` Length Dia. Dist. to Well SOIL ABSORPTION SYSTEM BED/TRENCH Width Length No. Of Trenches PIT DIMENSIONS No. Of Pits Inside Dia. Liquid Depth ~ 9 ~ L DIMENSIONS °VV SETBACK SYSTEM TO P/L / BLDG WELL LAKE/STREAM LEACHING Manufacturer: INFORMATION CHAMBER OR cr (4-r. Ty~D System, / UNIT Model u~ ear: DISTRIBUTION SYSTEM 6 11, `7 A54 117 : 3 Header/Manifoll Distribution ` x Hole Size x Hole Spacing Vent to Air,~ptake t Length ~P 9 5 G~ 1Length___ Dia Len Dia acin SOIL COVER x Pressure Systems Only xx Mound Or At-Grade Systems Only Depth Over Depth Over xx Depth of xx Seeded/Sodded xx M Iched Bed/Trench Center Bed/Trench Ed es Topsoil g Yes ❑ No Yes ❑ No COMMENTS: (Include code discrepencies, persons present, etc.) Inspection #1: Inspection #2: Location: w/ C-41/~w 5 ~ 1.) Alt BM Description = "y,b~` 661 S• ~,s Ce n~L+ C,6 2.) Bldg sewer length = t 4` 111 t~-J,/I , ►1 i 6 1 _ _ J it l 60 - amount of cover = 15w s Plan revision Required? ❑ Yes ~No Use other side for additional information. ~Q Y✓ SBD-6710 (R.3/97) Date ICert. No. A N -Do 17 - /Y,S `Kyxrit~ ~Q IndusbY Smi Lei to CwIty WashinOo Y; ` ! "SAY 2 2017 ~ n Ave 716 ~P_..6 Alf, ~ S-n Permit N too be fined in ~ C G.) 16 CROK COUNTY 73 it Appfication Number L is required " With SPS 383 7](2) , Wis. Adm. submissim ubm • of €hIs farm to the zPPrPij, ' gfim to abMining a sx~ L NOW "le DqwftneW tat Of rims fair s f st~C ate to rrul= lxw= ( [bars ) lion you prOv~& may be used for secundaq in Privarv i- a ]IZ I ea - 1. A tie rMn ej A A" \4 P-perty s Itag Address 4/ ;r Prate 14 a It. 14 city, f Zip Cede Govt. Lot SmIt / Type oiPB ( t uP y) et -MC ] or2 Faruity y Img-Numberrf ~ 0 T N, R - i Subdivs`sitaa x:mse b f - Btmk #i C1 L~ city of ~s CSM Number _ Va3laof. ~ Ft2-fist f-{~t173~%~ Q 2de,u 5}stefls s~ 3, ti ~._rL,y S~~ ~ wG- gTa astsett AtodxfiiauptoE~ristingS {i].^:s} A- rr~sau taer~.-vas txeY;s of 3~um ~ Expiration - h a + t3efare it Transfer tai New dV `I' of P0 Own" i~ I S s vaa ]n { €aefrati ❑ ad s D At-Grade 0 offoidmgTank - > 24 in, of MU 11 Maud < 24 in, of Wund V. Lis' Q -,'i (d t~ [design A t P 1' - ) r r gn Ste] scatraal'ate ,i' Area Kdquard fs#3 s 1 Mars Tank Info ly, ri low ~ of ram T = r r Czat]rms unit ~ L 4. v vs ri, --i,-~ C7 of i L'v i u t: v ,Y P t ?-fr,A L' VrL Peg Mumbez's s Si of 13usin= Phone Number ]']mnber's Address (5 City, Stu, zip Cbdc) 7 q' ~ VIII. an 3b 1-7 6 } ovec] 4-1_h=777V~rc;I ]ta'ulit Fee D issuisag A east S S 41 -F.5 . .M lNippA.]d uald;uawa5ejet: gad sF 3~ ~r i'~i X144 tUta '>fue~ .:~adaS ' t / 443N An w3j.sxs i i ' PLC! rl_rm) y OWNER J~gi~A+gz y SEC. T N-% W ADDRESS ST. CROIX COUNTY, WISCONSIN SUSt724TSION--- LOT - LOT SIZE? 'ILI PLAN VIEW Distances and dimensions to meet requirements of SHOW EVERYTHING WITHIN 100 FEET OF SYSTEM J lit` w! Y 1 INDICATE NORTH ARROW %✓C ,:~CALC BENCHMARK: Describe the vertical reference point used - Elevation of vertical reference point: Proposed slope at site: ; SEPTIC TANK: Manufacturer: Liquid Capacity: Number of rings used: J Tank manhole cover elevation: Tank Inlet Elevation: Tank Outlet Elevation: Number of feet from nearest Road: Front ,oSide 0Bear, feet From nearest property line : Front, Side ,~Rear, O ~.7 feet Humber of feet from. sell , building: (Include this information of the above plot plan)( 2 -reference dimensions to septic tank) SEE REVERSE SIDE PAGE 1 OF 4 In-Ground n Index & Cover Sheet Versa ' 1.0, St O-i M&P 11 1, R. 10112) i of Index Comer Sheet 9 P of 4 Plot Flan of Dispersal Area Cross-Section & Plan View P 4 el III, Management Plan Attachments: POWTS Application for Review Soil Evaluation Report Site Map Project Name i Description ow.ner A (TP) F~ ter` ":1 Phone: - - OwnerAddress: 't? P qi# t`~th >r n i:. Zip: 0 tc7 Project Address: 1 (rte A+i A ( Kf,"Q N+ Govt. Lot: - 114 of Section__- _~j__, TZ,,L_N-R f0 E F1 or WP1 Township: -1 ~LL~ U Project Parcel ll3 Designer Information, DL-signer am Phone: ?1-5 - 142 - t?7~5" Designer Address: Z1;?LJ17-J WT 23p: l1; _ _ tit ( 4eY-,~ e-,51 6,) v I to K e 6 vA 5 sga r"~s x ec ~ sta . License Number. ~3q - 06 -7 Remarks: ~ ~ ~g~, My c gs ` R ii0 ff 5.~~i {C •9 %ry f 1its~'''{'h+~°tffasl~$#i Signature: L, date. _ r - > care an su ed copy, OWNER SEC. W rwDxESS 1 STa CR011 COUNTY, vISCONSI:14 SUBDIVIISTON LOT LOT SIZE PLAN VIEW Distances and dimensions to meet requirements of SHOW EVERYTHING WITHIN 100 FEET OF SYSTEM t 1 4 / ll Vt,v 3.4 :a .s INDICATE NORTH ARROW BENCHMARK: Describe the vertical reference paint used - Elevation of vertical reference point ,'y i roposed slope at site. ~ SEPTIC TANK; Manufacturer: ~ Ziquid Capacity: Number of rings used: j' Tank manhole cover elevation: Tank Inlet Elevation: Tank Outlet Elevation; Number of feet from nearest Road: Front Side Rear, f/ feet From nearest property line Front, Side, Rear, 0 feet Number of feet from: well building: (include this information of the above plot plan)( -reference dimensions ddimensions to septic tank) SEE REVERSE SIDE s C ~ z - ~ v ~ a,. "~n4 -`.~2~a3';~c~3 t i ~"°;a :rig-,~ 4 i ~ 1 T re - ~2d=tf~4L ~r ...tea w u~ f~_ • ~ rti4e iYLl~s-~ i~y~`~ \L L •.rt~ `--'`~-.1 ~`ly .:y~ (mot 'a+ ` - ~ i r_. C'`''' . •ta lij'_t ~~"i' - - c. ! i ~~j~ -::i-~ i :i~? f7 T, PAGE 4 OF 4 r 2v ty Management Flan IMPORTANT: l i-E ru%'r'"r'tTFF C`'ItES it+rc%_+i+.i Frt~4i; yste,n Sh, rLS erns: is for itc ; ~r~ t+` a.? or c:sEvE? and F:lc rtt~r~arEwu Pursuant to requirements of SPs 382-384, Wisc. Admin. Corte. Pursuant to SPS 383.52 (2), Wisc. Admin. Code, this system shall he considered a human health hazard if not maintained in accordance with this approved management plan. `a~fth~°r*ttra~ 2El n ar+d rrain#enc'n^e ^~tivctES a r r s ShSl! ? parform. ed by a regist~fe..d ~ AFTS M'aintaniner In accordance with SPS 333.52 (3), Wisc. Admin. Corte. inf{ DiceaE Arb einn i irrst: Design Flow = t ` q d, 005; 224 rng 1 16() ML , FOGS 30 mtgLR " lr a :ti r Chi INSF CT FRY 3 "EAR'S o type of use 0 age of system r r i~r fa- Eor= (t.. +tL? S. I-~; cc's zl"+ o mechanical malfunction (i.e., trumps, valves, svAtches, floats, etc.) aterai fatiru-~ rf.L., lu l s braalts, corros?.ten, etc.) o solids volume in an obit treatment tank(s) and any distribution appurtenance(s) (i.e., distributicn t dre , n•~ o neglect or improper use (ie,, exceeding design capacities, prohibited activities, etc, c, extent of ponding ;n fttnbuticn cell Prior to dosing o dosing irregularities - if applicable (i.e., pump re-cycling, float switch settings, etc.; o electrical components - if applicable (i.e., wiring, connections, switches, controls, o distribution lateral or lateral orifice plugging (measure lateral distal pressure compare: to design specification) o surface discharge of effluent or sewage back-up into structure served 11ainteriance, Checklist NTAtN EVERY 3 YEARS (err when necessary) ° pc and dose tankis3 shall be pumped b a certified by septage servicing operator licensed under s. 2$1.4$ this. Stats. when the volume of solids in the tank(s) exceeds one-third (1/3) the liquid volume of the tame(s) or as r sired by l al nr narsce. Disposal of con, ents shall be pursuant to NR 113, Misc. Admin. Code. e fFluert$ filter(s) shall be inspected every 3 years and shall be cleaned when necessary to remove any accumulated solids according to manufacturers specifications. A servicing period will always be greater than 12 nnorths. System maintenance reports shall be submitted to the proper local government unit in accordance verith SIBS 38-33.65 Wi mac. Ad-min. Crde mss, art ay co3nporer t ta?lu or malfunction .o. Name of individual or company: V ~:i7 "Tl s 11, Phone: Local government unit: ` t a 7) 51 Local government snit address: ~ zl t~ _ . - zlp. I _ Any defective part of this system shall be repaired, replaced, or removed pursuant to SPS 383.51 (1), l!►dlsG. Admin. Code. Repair or replacement of failed or malfunctioning components shall comply with SPS 383, Wisc. Admin. Cade. No product for chemical or physical restoration of the POW TS may be used unless approved by the department in accordance with SPS 384, Wisc. Admin. Code. Ct3ntingRfl a!M In the event that any failed treatment component of this POWTS cannot be repaired, it shall be replaced pursuant to a plan submitted to the appropriate agency for review and approval. A failed in-ground dispersal component may be abandon and replaced by a code- xornpl'} r ing dispe ai c-C?r1`?pi1E'te`?b in :.z pJ"^-t et 'r??3!Y?eL'• area of 5:.,';t?.b;'=:.".C1FS. S4+s#~rat !'9Cl4~YtrYlPng i £ 5v' of this P{} is L'wCur`$;1, ,U_-'C, ff shall be eba rdonedi in a,:= oran-.e with v~'S I'h 0nlY Septic Tank, Filter Yo 'll Ever Need air Home Our i lit nr The lifetime filter T t' The lifetime filter is the most efficient, low maintenance effluent filter on the market, rated 3500 GPD. With nearly trice the filtering capacity of other filters, lifetime filter is the best value Thor your dollar. The unique plate design eliminates the collection of solids inside the car Fridge virtually eliminating maintenance. Cleaning is made easy through the elimination of solids trapped between plates, making the time to clean and replace minimal. Our unique, durable construction and patented design insures the ultimate protection of the drain field. ' he lifetime filter is available in 1/8",1./16",1/32" and i/64" filtration sizes. in ad{dFil in~Oi~r dIStr€ ~'tQrs b,~ f5n direct#y €lill the mane OCMer al'o,,;vs them to g°t ou, !iru.~iLCi. t t t ens ijSor t 4-;j rrn rt hlY v.; Pie ~ tit°fi {It ; t:rt' f , JC I! J. Single-Piece FIil - se Fade of high quality materials, this single-piece filter case provides Our u{ni,,ue!tr designed sinal-p-ole(p filter ease contains nc n lr ~ ti _ glue or s( r,r n P m (!4.t:~t'?: ~f~i 7.~'~.,I?~._'.~~t'r~e•zif''., C'. q.^,•~'-. -=.t ,¢.A'`.. ?;v,~~,_-'r"~P~~~ v'S !i --g sX yrt ~'Psk A Won yy 4,4 The Quick4u Standard Charnber fits in a 36" pride trench and is ideal for curved or straight systems. It features the patent-pending Contour Swivel Connection- which permits turns up to 15°, right x left. The MultiPortn* endcap allows multiple piping options and eliminates pipe fittings. The chamber's farm-foot length provides optimal installation - , flexibility. • Advanced contouring connections swivel up to 15°, right or left Latching mechanism allows for quick installation - • Four-foot chambers are easy to handle and install `tom The Quick Standard Chamber supports wheel loads of 16,000 lbslaxle with only 12" of cover' Certified by the international Association= of Plumbing and,%Aechanicai Officials (lAP O) • Tear-out seals on inlet ports provide a tight fit to the pipe _ • Fight molded-in in€etsloutiets allow for maximum piping flexibility Eliminates pipe fittings - Fits on either end of the Quick4 Standard Chamber APPROVED in QuicM Standard Chamber = = V, 77 f 11 3 t" - t- - 48' (EFFECTIVE LENGTH) FRONT VIEW SIDE VIRIJ TOP VIEW Typical Trench Lew iN-FILTft'iTOR HATER TECHNo-cca STAN=RD u r W a - (a) The structural integrity at each chamfer. endcap and other accessary manifzi #cred by Infiltrator ( Units"(. when installed and c;perated in a teacttlield of an onsite septic system TMATWE BACKRU TO MIL accordance with'Infttrdtor's mstn-^tEtm is rarrahlad to ore Oi~ pxchesff (-Honer,) Fjg defccut a mate:ias grad v.,o unernsh' for one year from the date that the '-yea- .x_---~------ Rs septic ¢mrtitis issjr,dthe septic system contaitog the Units provided. howeasr. that if a septic permit is not required b ' COVER BY'~ ? apgrGcaiye Law. the v.arr, ty 3 period u begsr t l the date ttrat a dlaiitar of the septic system U£SIGhI commences, To exercise Hs warranty rkpts. Holder must notify inatrator in vmtirrg at its Corporate Headquarters in Old Saybrook, Ccnt:ecfowt ailhin fifteen (151 days of the alleged defect. Infiltrator 12" v.41 supply rep aca Lkwts for emits daternimed by tntr3tralor to be curled by this United A a- trivERT waranty. f"Strator's liability specifrcagy excludes the cost of removal and- r installation of Gee Lklits. ~-34--- - - SPAO PER CC?D 31 d6) THE LIMITED WA€?RANTY AND ft&AMES W St113PA H (at AFE EXCLUSNE tx-tra lcrtt::.+te THERE ARE NO OTHER WARRANTIES WITH RESPECT TO THE UNITS. INCLUDING NO IMPLIED WARRANTIES OF VERCKWABILRY OR FITNESS FOR A PARTICULAR PURPOSE Cc} This Cure-ted Warrrnly stag be void if any part of the chamb r system is rnartuf ctured by anyorie caw than Infiiltrator. The LvWed Warranty does nK extend to maderual. ccnsequent t. speeciai or indieci damages. Infiltrator shatf not be liable for penalties or liquidated damages. Size 34"W x 53"L x 12r1H ockidog lass of production arxt omits. labor and materr%aK merhwd rocs. or other losses or (864 mm x 1346 mm x 305 mm) expenses m cared by the Holder or any third party. SpecificaVy excluded trait Loved Warranty coverage are damage to the Units due to orci Lary wear and tear. alteration, accident misuse. Effective Length 48" (1219 mm) abuse or ner if sect of the Units: the Urns t suh ected to veftide traft~ or other aartdit ions which are not perrnritted by the insratia# r instructions: tadwe to maintain the nt n mum ground covers Louver Height 8" (243 mm) set forth it the ins r instructions; the placement of improper mater.&I. info the system ccrdainog me Ulits, fau"re of the units or the septic system to wpoper siting or improper Storage Capacity 43 gal (163 Q sing. excessive cater usage. improper grease dispos;itl, or improper operaucri: or any other event rKA Ca d try tnliihator. Tres Lented Warranty Shad be Vow if the HOW" IZU to candy Invert Height 8" (2 ~ ff36T7) vAth alt of the terms set faith in this Limited Warranty. Fi.Cher. in no event trtlittrator be " L for any tt>ss or damage to the Hodder, the, Ururs or oily third party re" tram 41staitatio or shunt. or train arty predict liability cGairrts of Hauer or any third party. For this _;If AW Warsar+ty to amity. „ M Units r=ust be instil ltd in a^uxr,}a a wdh as sire c..rdi!iorS ref b,ed by state and focal nodes; a4 otter IyeiN anal atf~r~w's insallation irstnuctiors. (di No representative of Infiltrator has the auGtaity to change or edend this Limited Warranty. iG~ .:rarramy app-- to any party other Char; the ar +ar Heider. The above represents the Standard Limited Wan only, offered by Inf>ttrator. A Gnsited ntanber of 4 Bush-. Park Road stales and counter have different %7. arranty regcnrerrrenis Any pt ahZSW of UrA5 shotdd cortect Box 768 Old trrFJbator's Corporate Headquartfas in Cad Saybrook Conciseicut, pry to uxh piochase, to cxa s~y3goah cr os 17s obtain a copy of tre a reabte- vv isc0-~-7t'31i0 -Fax tires-~-1001 p}' r~Pt a^':z"tY, aril snovki r.araE[tay oaf Uri n2ty prior to the 2-840-222-4436 purchase at Unity -uttiltratorlmaterrwrtt U.S.P 4XO-661:5.017.011:5.156,488:5.3JY17:5,401.116: 5.401.359! 5.511.9c3: 5.716,163: 5.5E$-775:5.839,&31C.n-1aUisn i3a2ejus: 1.3*.9.Vys: Z004.564 pittcv pa;mts {kver4rg. tn{estata. EgLot ter- Qtva'i"- and aVsuYr xa recsteied uadernwlz of Witvziar t*r Techni:iw~ Infiltrator is a remstered in fiance. 1tadtr-.ttor water T is a req.tered at klexim. c.or::cna. M-. . PdyTutf, error,-'> . t Positack,. O=kcuL - , gri t-a# ant are uawnans of Lihmrator water T PoiyLok is a trademark of Pc.1yLolt. Inc. TUF-TTfE is a teyestered trademark of TUF-T(TE. INC. Uttia-Rib is a traziernark of MEX Inc. 21313 W.Uria s Wmer Tear -:--z. LLC, Ad rig~t= res rled. P cit d M U.Ss% 0250813 a IiII a Uv u ~a " "•i Q.n nip C O $ w N P. t. I oc ( n O ~J u N r U. Own 6 4 42, V c H w c 40 0 E _t 'S n x oo U ~'1~~~ v. v . 4 a a > eye w f o F~ zdw 5` v i m]~ H l~Tjl ` I~ U 'n s u l7, o, Z f G p f LL y .t, C l l ao O UP ff' I r U Q ? N W I fu ❑ C a it ~j ~ x4 y ~ W W ' Zn z ¢ - - a a4 o w ~ Ic•.. qo ao n, 6 O~ f n rt 3 W p ) l lu 06 r- 8 n a r[ ry O > a j y ay 0. H e ' mX O ~ ~ F ~ aq3q . ~ W 2 (L a ~4 yQ gs IT z~ pp N~ f, OT 73 cli Q ° =nn 3 td a 11s11~~ Q 0~ $Y N T. R ZUQ O F5 o1S- U 'O wTnT VA O 0 a CC O ^m p` u N a 3 z Q0 D 4 N a° 2; Wga v w a ~I ((UJJ 0 pD O "u 0_'. NLLN OS yy~~, m LL UU' Jz Z 3f 406w m - W z U tr a Y~n a Q o w a 66 c~ c7 d o ff, Q ~Zwp Z j O Cz ex. v. _ _ V vOLD Q O J UU1- (O 0 V O Y~ J ? O a E lZ~ ni G, ( w. Iz ue~~EE4p wrv O W N W U' Z~y ~ E~~q K h N N U OO ~6 ~'UV'{BU l ~ O a zo, oD pod ZzxxOy u'jO0 O OM w~ai,'i'4La6 ~tsti O fir{ z~ rt 'u77C~CVy3~~~°pwF.o d~po w OQZUtw-d¢Uz-u)Llw J c~awzarcrrx~~z v, zoLrg°mmj~' uuz 3 A . . LL Z`y ~w 4QZ¢ U00 m [L - N D : F- C7 a OXXXW W !a- U r`- ¢OL Q2Z u ----i luaulrockuo~-~'ruuluotoJ(Ti01v.Vllyl:!uolpap;o•;l~olpe;~l/s>,voUslanpa~{SP•Y.N~+~P:=3»nus~6W~;~u~aI:C7 tanks IM-1060 • Strong injection molded polypropylene construction Lightweight plastic construction and inboard lifting lugs allow for ! easy delivery and handling ' "Ji Integral heavy-duty green lids that interconnect with TWTM risers and pipe riser solutions Structurally reinforced access t ~ ports eliminate distortion during , r installation and pump-outs Reinforced structural ribbing and fiberglass bulkheads offer additional strength • Can be installed with 6" to 48" of cover The Infiltrator IM-1060 is a lightweight strong and durable septic tank. Can be pumped dry during This watertight tank design is offered with Infiltrator's line of custom-fit pump-outs risers and heavy-duty lids. Infiltrator injection molded tanks provide a • Suitable for use as a septic revolutionary improvement in plastic septic tank design, offering long-term pump tank, or rainwater exceptional strength and watertightness. (non-potable) tank Inlet Side No special installation, backfill or TANK CUTAWAY Infiltrator. water filling procedures are required TW Riser - System r x HEAVY DUTY LID CUTAWAY r. Reinforced Partition 24" structural baffle wali' access port A, Structural . bulkheads MID-SEAM CUTAWAY Reinforced water tight mid-seam gasketed connection