Loading...
HomeMy WebLinkAbout034-1002-10-100 (2) Wisconsin Department of Commerce PRIVATE SEWAGE SYSTEM County: St. Croix Safety and Building Division INSPECTION REPORT Sanitary Permit No: (ATTACH TO PERMIT) 605018 GENERAL INFORMATION State Plan 1D 3101776 Personal information you provide may be used for secondary purposes [Privacy Law, s.15.04 (1)(m)]. Permit Holder's Name: Village Township Parcel Tax No: Travis Teiger City TOWN OF SPRINGFIELD 034-1002-10-100 CST BM Elev: Insp. BM Elev: BM Description: Section/Town/Range/Map No: 02.29.15.178 TANK INFORMATION ELEVATION DATA TYPE MANUFACTURER CAPACITY STATION BS HI FS ELEV. Septic Benchmark Dosing Alt. BM Aeration Bldg. Sewer Holding St/Ht Inlet St/Ht Outlet TANK SETBACK INFORMATION TANK TO P/L WELL BLDG. Vent to Air Intake ROAD Dt Inlet Septic Dt Bottom Dosing Header/Man. Aeration Dist. Pipe Holding Bot. System Final Grade PUMP/SIPHON INFORMATION Manufacturer Demand St Cover GPM Model Number TDH Lift Friction Loss System Head T DH Ft Forcemain Length Dia. Dist. to Well SOIL ABSORPTION SYSTEM BED/TRENCH Width Length No. Of Trenches PIT DIMENSIONS No. Of Pits Inside Dia. Liquid Depth DIMENSIONS SETBACK SYSTEM TO P/L BLDG WELL LAKE/STREAM LEACHING Manufacturer: INFORMATION CHAMBER OR Type Of System: UNIT Model Number: DISTRIBUTION SYSTEM Header/Manifold Distribution x Hole Size x Hole Spacing Vent to Air Intake Pipe(s) Length Dia Length Dia Spacing SOIL COVER x Pressure Systems Only xx Mound Or At-Grade Systems Only Depth Over Depth over xx Depth of r777e7odded xx Mulched Bed/Trench Center Bed/Trench Edges Topsoil Yes No ❑ Yes ❑ No COMMENTS: (Include code discrePencies. Persons present, etc.) Inspection #11: Inspection #2: Location: 1193 RUSTIC RD R4 1.) Alt BM Description = 2.) Bldg sewer length = - amount of cover = Plan revision Required? ❑ Yes ❑ No Use other side for additional information. Date Insepctor's Signature Cert . No. SBD-6710 (R.3/97) ;~~,PARTd! j.h _ Count r- k'0 ED ~1 Industry Services Division ~p(~p Sp~ 1400 E Washington Ave P.O. Box 7162 Sanitary Permit Number (to be filled in by Co.) S `R Madison, WI 53707-7162 MAY 2 5 2018 U ~te Transaction Number Sanit Permit Application In accordance with SPS,38~) ion of this form to the appropriate Bove t 16177(o is required prior to obtaining a sanitary permit. Note: Application forms for state-owned P u mitt. L0 the Department of Safety and Professional Services. Personal information you provide may be used for secondary roject Address (if different than mailing address) purposes in accordance with the Privac Law, s. 15.04(1)(m , Stats. C: 1. Application Information - Please Print All In tion P'S i~ 4 Property Owner's Name ( Parcel # f2 Ik~II S TE Property Owner's Mailing Address Property Location iv: ISM 1-7 I ! i c- 4 Govt. Lot City, State A. Zip Code Phone Number &7'/4, Section ?I ircle one) Tp~ IN R~ Eoo j Al .Type of Building (check all !tha pply) Lot # Aor 2 Family Dwelling - Numbof Bedrooms Subdivision Name ❑ Public/Commercial - Describe Use 6k Block # ❑ State Owned - Descrbe Use V wa)wjA, PID Zdt N%._ ❑ City of /a C M Number❑~Village of o O 4JA s~~6_6 /sg$ Z rownof ~ ~Wr,~ III. T e of Permit: (Check only one box on line A. Complete line B if applicabl d6n ^4, A. [`New System ❑ Replacement System ❑ Treatment/Holding Tank Replacement Only ❑ Other Modification to Existing System (explain) B. El Permit Renewal El Permit Revision ❑ Change of ❑ Permit Transfer to New List Previous Permit Number and Date Issued Before Expiration Plumber Owner / IV. Type of POWTS System/Component/Device: (Check all that apply) ❑ Non-Pressurized In-Ground ❑ Pressurized In-Ground ❑ At-Grade round > 24 in. of suitable soil ❑ Mound < 24 in. of suitable soil ❑ Holding Tank ❑ Other Dispersal Component (explain) ❑ Pretreatment Device (explain) V. Dis ersal/Treatm t Area Information: j'►~~ Design Flow (gpd) Design Soil Applic1atio/n DispersalrArea Re uired (st) Dispersal Area Proposed st) System /Elevation 4Q Rate(gPds~ x `"1 1 l I . vv t/ VI. Tank Info Capacity in Gallons Total # of ' o anufacturer v U Gallons Units F ❑ Y New Tanks Existing Tanks t U ti a A-L Septic or "okkngfank cob C'- El E] 1:1 El Dosing Chamber T'h ~Ifej ❑ ❑ ❑ ❑ VII. Responsibility Statement- 1, the undersigned, assu responsibili installation of the POWT~S-"shown on the attached plans. Plumber's Name (Print) Plumb s Si rr n MP/MPRS Number Business Phone Number Todd L Sinz I~ICJ!(C/i MP139462 715-235-2644 Plumber's Address (Street, City, State, Zip Code) E5609 708`h Ave Menomonie Wi 54751 VIII. oun /De artment Use Only 'KA pproved Permit Fee Dtat Issu Q Issui Agent Sign r Owner Given Reason r Denial $ (O 40• 00 J ~l V IX. Condi f W1.1 earns f Disapproval 7\ l~~,Yldl .k R • A,, dti/ MM~w'r JJ r,ispen't-4o cell must rih ~Rf .'rte ~frnoft:i gas per management plan p'o+ide.d by plwtbe. epwej L4.jl 4-" M,1 2. /►g ie recr m-ieni8;mli st w- rrair tc it`E i as per I icar3bl.sctuiel;.rdira, nA. 14 6U Attach to complete plans for the system and su it to the County only on paper of less than 8 to x I I ches in size /1 1/W1iN►Qi 15 Jam- /~~_O~r) SBD-6398 (R03/14) 1 n / / ooa C 3 @ ` Tell I` O 3 9 F a ~ ~A. l ~ ^ nb ~ t f 8' r 1 f l`~ F f !T t ~ ~ ~ E ? j i 7 ~ Tar._ z } z ~ f I~ F All io v t t Y f i Conditionally DIVISION OF INDUSTRY SERVICES ` APPROVED 2331 SAN LUIS PL STE 150 r R Y C GREEN BAY WI 54304-5211 0 S DEPT. OF SAFETY AND PROFESSIONAL Contact Through Relay P S SERVICES http://dsps.wi.gov/programs/industry-services DIVISION OF INDUSTRY SERVICES www.wisconsin.gov ~'T ~O Scott Walker, Governor d Z/ c/ Laura Guti6rrez, Secretary May 24, 2018 SEE CORRESPONDENCE CUST ID No. 139462 ATTN: POWTS Inspector TODD L SINZ ZONING OFFICE TL SINZ PLUMBING INC ST CROIX COUNTY SPIA E5609 708TH AVE 1101 CARMICHAEL RD MENOMONIE WI 54751-5520 HUDSON WI 54016-7708 CONDITIONAL APPROVAL PLAN APPROVAL EXPIRES: 05/24/2020 Identification Numbers Transaction ID No. 3101776 SITE: Site ID No. 849198 Travis Tei2en Please refer to both identification numbers, Rustic Rd 4 above, in all correspondence with the agency. Town of Glenwood St Croix County NE1/4, NEI/4, S2, T29N, R15W FOR: Description: Mound System (3 Bedrooms - New Construction) Object Type: POWTS Component Manual Regulated Object ID No.: 1761728 Maintenance required; 450 GPD Flow rate: 25 in Soil minimum death to limiting factor from original grade; System(s): Mound Component Manual - Ver. 2.0, SBD -10691-P (N.01/O1, R. 10/12), Pressure Distribution Component Manual - Ver. 2.0, SBD-10706-P (N.01/01, R. 10/12), SSWMP Pub. 9.6; Effluent Filter The submittal described above has been reviewed for conformance with applicable Wisconsin Administrative Codes and Wisconsin Statutes. The submittal has been CONDITIONALLY APPROVED. This system is to be constructed and located in accordance with the enclosed approved plans and with any component manual(s) referenced above. The owner, as defined in chapter 101.01(10), Wisconsin Statutes, is responsible for compliance with all code requirements. No person may engage in or work at plumbing in the state unless licensed to do so by the Department per s.145.06, stats. The following conditions shall be met during construction or installation and prior to occupancy or use: • Preserve dispersal area prior and during construction to avoid disturbance, compaction and use of the site. • With new construction; it is recommended not to activate the pump in the dose tank until the tanks are pumped prior to homeowner occupancy. • Wastewater generated from contractors cleaning of equipment and tools and/or left over construction products shall not be discharged into the drains discharging to the private onsite wastewater treatment system (POWTS). Waste generated shall be properly disposed of on-site or off site. • Any tall grasses, leaves and shrubs shall be cut short and removed prior to tilling the surface for installation to prevent matting under the dispersal area. All loose organic material to be removed from mound area. • Divert surface water from POWTS Area. • Prior to construction of the dispersal area, check the moisture content of the soil to a depth of 8 inches. Smearing and compacting of wet soil will result in reducing the infiltration capacity of the soil. Proper soil moisture content can be determined by rolling a soil sample between the hands. If it rolls into a 1/4- inch wire, the site is too wet to prepare. If it crumbles, site preparation can proceed. If the site is too wet to prepare, do not proceed until it dries. • All piping shall conform to SPS Table 384.30-3 and SPS Table 384.30-5 TODD L SINZ Page 2 5/24/2018 • Insulate building sewer beyond 30 feet per SPS 382.30 (11)(c) • Well setbacks to meet chs. NR 811 & 812 • Tank Installation to follow all manufacture's recommendations. • SPS 383.54(1)(e) The management plan for a POWTS shall specifically address the servicing mechanics of an aerobic or anaerobic treatment tank or a holding tank where either of the following conditions exist: 1. The bottom of the tank is located more than 15 feet below the elevation where the servicing pad is located. 2. The bottom of the tank is located more than 150 feet horizontally from where the servicing pad is located. • Verify property line(s) prior to installation. • Pump Floats to be set and verified per approved plan. Any changes may result in pump resizing to meet TDH and GPM Specifications. areas that are occupied with rock fragments, tree roots, stumps and boulders reduce the amount of soil available for proper treatment. If no other site is available, trees in the basal area of the mound must be cutoff at ground level. A larger fill area is necessary when any of the above conditions are encountered, to provide sufficient infiltrative area. Owner Responsibilities • The current owner, and each subsequent owner, shall receive a copy of this letter including instructions relating to proper use and maintenance of the system. Owners shall receive a copy of the appropriate operation and maintenance manual and/or owner's manual for the POWTS described in this approval SPS 383.54(1). • In the event this soil absorption system or any of its component parts malfunctions so as to create a health hazard, the property owner must follow the contingency plan as described in the approved plans. A copy of the approved plans, specifications and this letter shall be on-site during construction and open to inspection by authorized representatives of the Department, which may include local inspectors. All permits required by the state or the local municipality shall be obtained prior to commencement of construction/instal lation/operation. In granting this approval the Division of Industry Services reserves the right to require changes or additions should conditions arise making them necessary for code compliance. As per state stats 101.12(2), nothing in this review shall relieve the designer of the responsibility for designing a safe building, structure, or component. Inquiries concerning this correspondence may be made to me at the telephone number listed below, or at the address on this letterhead. The above left addressee shall provide a copy of this letter and the POWTS management plan to the owner and any others who are responsible for the installation, operation or maintenance of the POWTS. Sincerely, Fee Required $ 250.00 This Amount Will Be Invoiced. When You Receive That Invoice, Tim Vander Leest Please Include a Copy With Your Payment Submittal. Private Sewage Plan Reviewer ,Division of Industry Services WiSMART code: 7633 (920)492-2214, Mon- Fri, 6:00 a.m. - 3:30 p.m. tim.vandcrlcc,,1 a`v. cc: Edwin A Taylor, Wastewater Specialist, (715) 634-3484, Mon-fri, 8:00 A.M. - 4:30 P.M. MOUND AND PRESSURE DISTRIBUTION COMPONENT DESIGN INDEX AND TITLE PAGE Project Name: Travis Tei er New Home. Conditionally APPKOVED Owner's Name: Travis Teigen DEPT. OF SAFETY AND PROFESSIONAL SERVICES Owner's Address: 1193 Rustic Road 4 DIVISION OF INDUSTRY SERVICES Glenwood City Wi 54013 tzw &Wla!.t~ 715-781-2094 SEE CORRESPONDENCE Legal Description: NE1/4 NE1/4 S2 T29N R15W Township: Glenwood County: St Croix Subdivision Name: 40 ac Site Lot Number: Block Number: Parcel I.D. Number: Plan Transaction No.: Page 1 Index and title Page 2 Data entry Page 3 Mound drawings Page 4 Lateral and dose tank Page 5 System maintenance specifications Page 6 Management and contingency plan Page 7 Pump curve and specifications Page 8 effluent filter Page 9 Plot Plan 1 Designer: Todd L Sinz ` License Number: MP 139462 Date: 05103/18 9 Phone Number: 715-235-2644 Signature: 1Ag) . < U esigned Pursuant to the Mound Component Manual for POWTS Version 2.0 SBD-10691-P (N. 01/01, R. 10/12), and both SSWMP Publication 9.6 Design of Pressure Distribution Networks for ST-SAS (01/81) and Pressure Distribution Component Manual Ver. 2.0 SBD-10706-P (N. 01/01, R. 10/12) Version 7.0 (R. 11/12) Page 1 of 9 Mound and Pressure Distribution Component Design site Information R' Residential or Commercial Design Norte: Sand fill (D) calculations assume a 300.00;: Estimated Wastewater Flow (gpd) Table 363-44-3 in-situ soil treatment for fecal coliform of - 36 inches, 1,50 Peaking Factor (e. g. 1.5 = 150%) E450 00 Design Flaw (gpd) 8.00 Site dope 100.00 Centaur Line Elevation (ft) 25.00 Depth to Limiting Factor (in) 0.40: In-situ Soil Application Rate (gpd/ft) Distribution Cell Information 75.00 Dispersal Cell Length Along Contour (ft) = 6.00 Cell Width (ft) 1,00 Dispersal Cell Design Loading Rate (gpolft2 I Influent Wastewater Quality (1 or 2) Are the laterals the highest point in the distribution Pressure Disriution Information network? Center or End Manifold 3.00 Lateral Spacing (ft) If N above, enter the elevation (ft) ? Number of Laterals of the highest point. 0.156 Orifice Diameter (in) 3.50 _ Orifice Spacing (ft) = 10.23 ft` /orifice 2.00 Forcemain Diameter (in) 85.00 Forcemain Length (ft) Does the forcemain drain back? 88.00 Pump Tank Elevation (ft) 1.06 System Head (ft) x 1.3 13,86 Forcemain Drainback (gal) Vertical Lift (ft) 67.44 5x Void Volume (gal) Friction Loss (ft) 81.30 Minimum Dose Volume (gal) 0.00 In-line Filter Lass (ft) 23.69 System Demand (gprn) 18.11 Total Dynamic Head (ft) Lateral tiameter Selection Manifold Diameter Selection in. dia. opticans choice in, dia. options choice 0.75 1.25 1.00 1.50 x x 1.25 2.00 1.50 x x 3.00 2.00 x 3.00 x Gallons/inch Calculator Treatment Tank Information Total Tank Capacity (gal) 1000.00 Septic Tank Capacity (gal) Total Working Liquid Depth (in) Wieser Concrete Manufacturer gallin (enter result in cell 849) Dose Tank Information Effluent Filter Information 60100. Dose Tank Capacity (gal) Lifetime Filter Manufacturer 11.82 Dose Tank Volume (gal/in) LT1l8 Filter Model Number Wieser Concrete Manufacturer Project: Travis Teiger New Name. Page 2 of 9 Mound Plan an Cross Section Views 1110 B J Observation Pipe . FK!. 1J A W r . Z 'v L Mound Component Dimensions A 6.00 ft E 16.76 in H 1.00 ft [all B 75.00 ft F 9.50 in - 1 Q.61 ft L 11.00 in G 0.50 ft J 5.34 ft W f? 450.00 (ft) Dispersal Cell Area 1245,59 (ft) Basal Area Avaiiabi ; ~ 6.00 (gpolft) Linear Loading Pate 7.50 (ft) 1110 B Obs. Pipe Placement Mound Cross Section View Aggregate Dispersal Area Finished Gracie 102.71 (ft) - ry-•-... . G H 2 41 F Dispersal Cell 101.42 (ft) Lateral 100.92 {ft}- Invert Dispersal Cell Elevation E D 4 Q 100.00 (ft) Contour Elevation 8.0 % Site Slope Geotextile Fabric Cover Shading Key Dispersal Cell See lateral details on Topsoil Cap C 1.5 ft Page 4 for number, Subsoil Cap, size, and spacing of ASTM C33 Sand laterals. Laterals are Tilled Layer d 0.5 ft Typical Lateral F equally spaced from the u~ distribution cell's Aggregate IT o centerline in the -A distribution cell (AxB). Project: Travis Teiger New Home. Page 3 of 9 End Connection Lateral Layout Diagram ~„tgri.: rr~r. ;,,eteV«~F~.3ir*-rr~Ye'r Tur;t...uFa'r.>t:~'I,al,. t-~:,lean outpluU -dell&d-nrh botl_rr, 4 04r I?metal X-1 A 7ar-ire X-1 3~ol Y r<rt: fn 41n "5rifi( tt 'ri oq r Of , tri fn eftih it l ~d 3 Nt C3 .ttt i Number of Laterals ~ 2 Orifice Diameter 0.156 it Lateral Diameter 1.54 in Orifice Spacing (X) 3.50 ft Lateral Length (P) 73.54 ft Orifices per Lateral 22 Lateral Spacing 3.44 fit Orifice Density 10.23 ft/orifice Lateral Flow Rate 11,85 gpm Manifold Length 3.44 ft System Flow Rate 23.69 gpm Manifold Diameter 1.54 in Total Dynamic Head 18.11 ft Forcemain Velocity 2.42 f#fsec Dose Tank Information Cracking saver with warning label and locking device and sealed watertight Electrical as per NEC 300 and SPS 316.30fl WAC 4 in. min. Disconnect Tank component is properly vented Alternate outlet location Forcemain diameter Wieser Concrete Manufacturer 2 in. Ca aci 643.40 Gallons Volume 11.82 gal/inch A Weep hole or anti- Dimension Inches Gallons B siphon device A 31.14 368.04 B 2.44 23.64 Pump off elevation (ft) 6.88 81.34 88.92 D 11.40 130.42 D Total 51.02 603.00 Dose tank elevation (ft) 3'" 0edding under tank. 88.00 Alarm Manuafacturer SJE RhombusW Alarm Model Number Tank Alert Pump Manufacturer Zoeller Pump Model Number BN 151 Pump Must Deliver 23.69 gpm at [::=ft TDH Project: Travis Teiger New Home. Page 4 of 9 Mound vats rote an a and er tdon eci is ions Service Provider's Name T L Sinz Plumbing Inc. Phone 715-235-2644 POWTS Regulator's Name St Croix County Zoning Phone 715-386-4686 System Flow and Load Parameters Design Flow - Peak 450 gpd Maximum Influent Particle Size 118 in Estimated Flow - Average 300 gpd Maximum BQD5 226 mg/L Septic Tank Capacity 10100 gal Maximum TSS 150 mgiL Soil Absorption Component Size 450 ftz Maximum FOG 30 mg/L Type of Wastewater Domestic Maximum Fecal Coliform >10E4 cfu1100 mL Service Frequency Septic and Pump Tank Inspect and/or service once eve 3 years Effluent Filter Should inspect and clean at least once every 3 ears Pump and Controls Test once eve 3 years Alarm Should test monthly Pressure System Laterals should be flushed and pressure tested every r_,3 ears Mound Inspect for ponding and seepage once every 3 years Miscellaneous Construction and Materials Standards 1, Observation pipes are slotted and materials conform to Table SPS 384.30-1, have a watertight cap, and are secured in as shown in the mound component manual. 2. Dispersal cell aggregate conforms to SPS 384,30 (6)(i), Wis, Adm, Code, 3. All gravity and pressure piping materials conform to the requirements in SPS 384; Wis. Adm. Code. 4_ Tillage of the basal area is accomplished with a mold board or chisel plow. 5e The mound structure and other disturbed areas will be seeded and mulched to prevent sail erosion and help reduce frost penetration. Lateral Turn- Detail Finished Grade , 6-8" Diameter Lawn Threaded Cleanout Sprinkler Valve Sox Plug or Ball Valve E I I . . Distribution Long Sweep 90 or Two 45 Degree Bends Sarn Diameter as Lateral Project: Travis Teiger New Home. Page 5 of 9 I III Mound System Management Plan Pursuant to SPS 383.54, Wis. Adm. Code General This system shall be operated in accordance with SPS 382-84 Wis. Adm. Code, and shall maintained in accordance with its' component manuals [SBD-10691-P (N.01101, R. 10112), SSWP P Publication 9.6 (01161), and Pressure Distribution Component Manual Ver. 2.0 SBD-10706-P (N. 01101, R. 10112)) and local or state rules pertaining to system maintenance and maintenance reporting. No one should ever enter a septic or pump tank since dangerous gases may be present that could cause death. Septic and pump tank abandonment shall be in accordance with SPS 38333, Wis. Adm. Code when the tanks are no longer used as POWTS components. Septic or pump tank manhole risers, access risers and covers should be inspected for water tightness and soundness. Access openings used for service and assessment shall be sealed watertight upon the completion of service. Any opening deemed unsound, defective, or subject to failure must be replaced. Exposed access openings greater than 8 -inches in diameter shall be secured by an effective locking device to prevent accidental or unauthorized entry into a tank or component. Septic Tank The septic tank shall be maintained by an individual certified to service septic tanks under s. 281.48, 5tats, The contents of the septic tank shall be disposed of in accordance with NR 113, Wis. Adm. Code. The operating condition of the septic tank and outlet filter shall be assessed at least once every 3 years by inspection. The outlet filter shall be cleaned as necessary to ensure proper operation. The filter cartridge should not be removed unless provisions are made to retain solids in the tank that may slough off the filter when removed from its enclosure. if the filter is equipped with an alarm, the filter shall be serviced if the alarm is activated continuously. Intermittent filter alarms may indicate surge flows or an impending continuous alarm. The septic tank shall have its contents removed when the volume of sludge and scum in the tank exceeds 113 the liquid volume of the tank. If the contents of the tank are not removed at the time of a triennial assessment, maintenance personnel shall advise the owner of when the next service needs to be performed to maintain less than maximum scum and sludge accumulation in the tank. The addition of biological or chemical additives to enhance septic tank performance is generally not required. However, if such products are used they shall be approved for septic tank use by the Department of Commerce. Pump Tank The pump (dosing) tank shall be inspected at least once every 3 years. All switches, alarms, and pumps shall be tested to verify proper operation. If an effluent filter is installed within the tank it shall be inspected and serviced as necessary. Mound and Pressure Distribution Svstem No trees or shrubs should be planted on the mound. Plantings may be made around the mound's perimeter, and the mound shall be seeded and mulched as necessary to prevent erosion and to provide some protection from frost penetration. Traffic (other than for vegetative maintenance) on the mound is not recommended since soil compaction may hinder aeration of the infiltrative surface within the mound and snow compaction in the winter will promote frost penetration, Cold weather installations (October-February) dictate that the mound be heavily mulched as protection from freezing. Influent quality into the mound system may not exceed 220 mgiL BOO,, 150 mgiL TSS, and 30 mg/L FOG for septic tank effluent or 30 mg/L BOD,, 30 mgiL TSS, 10 mgiL FOG, and 104 cful100 mL for highly treated effluent. Influent flow may not exceed maximum design flow specified in the permit for this installation. The pressure distribution system is provided with a flushing point at the end of each lateral, and it is recommended that each lateral be flushed of accumulated solids at least once every 18 months. When a pressure test is performed it should be compared to the initial test when the system was installed to determine if orifice clogging has occurred and if orifice cleaning is required to maintain equal distribution within the dispersal cell. Observation pipes within the dispersal cell shall be checked for effluent pending. Ponding levels shall be reported to the owner, and any levels above 6 inches considered as an impending hydraulic failure requiring additional, more frequent monitoring. Contingency Plan If the septic tank or any of its components become defective the tank or component shall be repaired or replaced to keep the system in proper operating condition. If the dosing tank, pump, pump controls, alarm or related wiring becomes defective the defective component(s) shall be immediately repaired or replaced with a component of the same or equal performance. If the mound component fails to accept wastewater or begins to discharge wastewater to the ground surface, it will be repaired or replaced in its' present location by increasing basal area if toe leakage occurs or by removing biologically clogged absorption and dispersal media, and related piping, and replacing said components as deemed necessary to bring the system into proper operating condition. See Page 5 of this plan for the name and telephone number of your local POW;fTS regulator and service provider. Pretreatment Units The information and schedule of mananagement and maintenance for pretreatment devices such as aerobic treatment units or disinfection units are attached as separate documents and are considered part of the overall management plan for this system. Project; Travis Teiger New Home. Page 6 of 9 Flow-Mate Dose-Mate WO In high head dewatering or effluent This is our fastest growing line of u applications where pumping affluent pumps.The 150 series is truly performance is critical, this robust a workhorse designed for reliability family of pumps is known for under extreme conditions in an effluent reliability, durability andperforrnance, environment. 150 series pump curves These pumps are especially suited for cover a wide range of applications, harsh environments. Zoeller's cool They are well suited to applications run design and corrosion-resistant, with low pressure pipe (LPP) and powder coated epoxy finish add up enhanced flow STEP systems.Zroeller`s toalong-lasting,trouble-free product. ool run design and corrosion- resistant, powder coated epoxy finish, in addition to the hertnetica l ly sealed, oil-filled motor and non-clogging vortex impeller add up to a long-lasting, trouble-free product. APPLICATIONS: APPLICATIONS: . STEP or onsite applications * STEP or onsite applications . Water transfer * Light commercial dewaterina . Light commercial dewat'ering SPECIFICATIONS: SPECIFICATION : * 1''W' NPT discharge * 1 1/2" NPT discharge * 3110 HP through 1/2 HP iz HP through 1 HP * Available in nonautomatic or with a variable level * Available in automatic or nonautomatic piggyback mechanical switch * Model 137, 139, 140: 1/" (13 inmj spherical solids * /2" (13 mm) spherical solids capacity with vortex capacity with vortex impeller thermoplastic impeller * Model 145: 3/4" (19 mm) spherical solids capacity with For more information, see Technical Data Sheet FA42784 vertex impeller * Bronze construction available (139 series) * High head version available (145 series) * Double shaft seal versions available for added protection on models 140/145, For more information, see Technical Data Sheets FM2782, FM2789 PUMP PERFORMANCE CURdE~ EIS PUMP PERFORMANCE CURVE ~ I'MODEL MODEL 15V1521153 '3 I Vl 1371139/1401145 i ' I I 14 153 ! i - 4 y -r--- i ti c c;l 10- m x a 51 - a is _ 20 - 4 i I i I 2 I I f f i 5.. 5 u6 ,3'I! I i 10 20 Rio ac 5c ao ru ao 90 loci ° GALLONS 30 b:-r0 63 A7 ro fm c uo s 1T TER: a 200 24G 250 37.0 NO 3r 120 eG =freRS ! f 4,j MV(PERWNU'IE 152655 FLOW PER MINUTE pt4'~v8 @ All rights reserved. ZOELLER PUMP Co. ~ 502-778-2731 1 800-925-7867 1 www.zoeller.com I The Best dust Got Better W - The most efficient, the lowest maintenance, the most economical effluent filter! a I~ Capacity the Filtering Nearly Ice tt} Est m >tec to 3 Times . Longer Between Cleanings ~o Cleaning e Easy I Ws Between Pates s Doe Not Retain 5 Lowest rice Uiy aces collects inside cartridge. Nearly twice filtering capacity of any other filter. By eliminating solids plates between drastically reduces the need to clean. Cleaning e sl i t L ~ ' III iii III',I;,' •~!'9, I Y i - LT-1/8: 3,500 s t Strength i" f ~9k3' Filtration /t T - 1/16: 335 / Residential Strength ,t Filtration 1/1611 LT - /32. 3000 GPD/Recommended for Commercial use with Residential Strength - Filtration 1/3211 1/ GPD/Recommended for Commiercial usage with Residential Strength - Filtration / `A f1ll i..e~~cbc e%-C 1 arags~w r-;I*rnf n (NIonviv i f hp ti nPf0f;llln) ?b$ 1 I IZN 10 ~Nn 1 a g f f`00 3 21 r_ Yi~ C '-J { T ~ - ~ Vii`. 1 I ' • i l ate- - - . I{I ~ ti J, .ii r♦. I r -fF:- TI. ~4"vl, '--y I y ry YF j c , I i iv+t 1 v9: e Zrr_~.- t _ - 1 I 9 e 11 - ---y', ~ ~ -i "d /sJ f I L L\1 ~ I RI n I ti ~ ~ 9 -f- cj- - ~ 1xU 01 i, I 3I I i I r o~ i $ I I I 9 ~~,eF ~ .oil i Alp ~ ~ t l ~ .,!r~dF I f ~Hi4Y l IF bt II.. v. 14 ST. CROIX COUNTY SEPTIC TANK MAINTENANCE AGREEMENT AND OWNERSHIP CERTIFICATION FORM Owner/Buyer (2on; A2 Mailing Addres d (l r%C /lt~*L~GrU C% Property !1 ' Address 7-S /~~•t ,`c.._ 1~0~ ~ f (Verification required from Planning & Zoning D artment for new construction.) City/State 61"I~,c0a c- 4,/ f~ Parcel Identification unmber LEGAL DESCRIPTION Property Location J1419 Sec. T gEj,_N R 15 W, Town of c Subdivision Plat: _ Lot # Certified Survey Map # Volume Page # Warranty Deed # (before 2007)Volutne Page # Spec house ❑y es Klto Lot lines identifiable ❑yesF] no SYSTEM MAINTENANCE AND OWNER CERTIFICATION Improper use and maintenance of your septic System Could result in its premature failure to handle wastes. Proper maintenance consists of um ing out the septic tank every three years or sooner, if needed, by a licensed pumper. What you put into the system can affect the function of the septic tank as a treatment stage in the waste disposal system. Owner maintenance responsibilities are specified in §SPS. 383.52(1) and in Chapter 12 - St. Croix County Sanitary Ordinance. The owner agrees to submit to St. Croix property County Planning & Zoning Department a certification four, signed by the owner and by a master plumber, journeyman plumber, restricted plumber or a licensed pumper verifying that (1) the on-site wastewater disposal system is in proper operating condition and/or (2) after inspection and pumping (if necessary), the septic tank is less than 1/3 full of sludge. I./we, the undersigned have read the above requirements and agree to maintain the private sewage disposal system with the standards set forth, herein, as set by the Department of Safety And Professional Services and the Department of Natural Resources, State of Wisconsin. Certification stating that our septic s stem has been maintained must be completed and returned the St. Croix County Planning Zoning Department within 30 days of the three year expiration date. I/we certify that all statements on th' form are true to the best of my/our knowledge. I/we am/are the owner(s) of the property described above, by virtue of a w anty deed recorded in Register of Deeds Office. Number of bedrooms -3 xf` v- - l - 5 f f S/ l SIGNAT a E OF APPLICANTS DATE ***Any information that is misrepresented may result in the sanitary permit being revoked by the Planning & Zoning Department. Include with this application a recorded warranty deed from the Register of Deeds Office and a copy of the certified survey map if reference is made in the warranty deed. (REV. 04/12) V►h fonai Services Page of Division ision 4 SOIL ENAL MON REPORT MAY 2 5 2019 1 In accordance with SPS 385, Wis. Adm. Code County Attach compts site plan on pap r not than 9112 x 11 inches in eke. Plan must include, ~ 4 C r O ti'~~ but not limited to: vertft tifdlh t naf n point (BM), direction and percent slope, Parcel 1• scale or dimahsiq~r6- d distance to nearest road. Please print all infonnation. Ravi by Da! Personal Information you provide maybe used forseconda u o Prtva Law 8.15.040)(m)). Property Owner Property Location TP q„J iS Govt. Lot N Y. S V T N R /6- s (or) W Property Owner's Mailing Address Lot # Stock # Subd. 14anne or CSM# t g 3 *f u-6 ~t c. i zoaA q LID Gity State Zip Code . Phone Number ❑ City Q Village S Town Nearest Road L>--~~ o C~ G.~C 54ot3 . ~'I4( ~aq`t G-~. S usCt~ ~d y v~4f a-New construction uqw. ®Residentiai/Numberofbedrooms 3 Code derived design flow rate9roZ? GPD ❑ Replacement ublic or commercial - Describe: Parent material tom` Z - L Flood Plan elevation if applicabieNA- ft. General commen and recommendations: r e co om AQ I V 5 "J; 40- wv o " ~ ~ • ~ lA o a ~ ?s ` t2~c ~c 1 j ~ 7s s . Boring D1 Boring # Pit Ground surface eleI v. Depth to limiting factor ~ in. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/Fe In. Munsell 'Qu. Az. Cont. Color Gr. Sz. Sh. *Eff#i `Eff#2 r [r- 9A '02, Z Is •J a 4 w~ c &C o . aQ 3 /sZ 5`12 s t I c.5 Z a^y c~C' s~ 'l•5 y2 y c-L. JK *<L s n•. r- p~ y o 3 Z_y 7 y R L3 qCAS1*L / SL a- o o-z T- i Baring 0Boring ' Pit Ground surface elev. ?Erft. Depth to limiting factor in. Sol[ Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/Fe In. Munseli Qu. Az. Cont. Color Gr. Sz. Sh.. "Efr#1 * 46 6 X-C. ZLL 6-9 04 4 L * Effluerrt #1 - B0D > 30 5 220 m L and TSS > 0 s * Effluent #2 = ROD > 30 s 220 2 and Tss > 30 s 150 m fL CST Name (Please Print) igna re CST Number Address Date lrvaluallon Conducted Telephone Number SBD-8330 (1104/15) Boring # Boring Pit Ground surface elev. (C)0 yft. Depth to limiting factor in. Soli A lication Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/Fe In. Munsell Qu. Az. Cont.-Color Gr. Sz. Sh. *Eff#1 *Eff#2 1 '~-5y~23 Z ~ aE s; 1 fs r~w.S~ o-~S z $ / S ~3`f Y s; 1 +~►~.s c~ Z.G. D- al5 3 26 -Y 's/ s 1c5 0%.~,• 5 216k 6-9 a.~ X6-33 75 `ill 44 c,c ~5~ti / l5 6.-7 Boring # ❑ Boring ❑ Pit Ground surface elev. ft. Depth to llmfiflng factor _ in. Soil A Ilcatlon Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/Ff In. Munsell Qu. Az. Cont. Color Gr. Sz. Sh. *Eff#1 'Eff#Z ❑ Boring # ❑ Boring ❑ Pit Ground surface elev. ft.- Depth to limiting factor In." Soil Application Rate Horizon Depth Dominant Color Redox Description Texture 'Structure Consistence Boundary Roots GPD/FYI In. Munsell Qu. Az. Cont. Color Gr. Sz. Sh. * Effluent #1 = SOD, > 30 5 220 mg/L and TSS > 30:s 150 mg/L • Effluent #2 = SOD, > 30 5 220 mg/L and TSS > 30 5150 mg/L M 7 40 a_ V c~- C t3 g '0 A h V C O 9) 2 Q N I M 3 / 10 J D / iqq Do t