Loading...
HomeMy WebLinkAbout176-1086-40-100 'vviscars~n Deoan-en'ct Cc-'-erce PRIVATE SEWAGE SYSTEM `'0001•' St. Croix Sare:/ and B.lilang U v s r INSPECTION REPORT San.lary Pcrrnil No GENERAL INFORMATION (ATTACH TO PI.-.Rra IT) 606921 Sa:e Plar lD .vo ) Persnrnl i^br..M or qoU r,vide r-aii oe u®eo'C' •enirda'y pu'ocses iPfl, Law s -5 C4 ;11:,111] 2(~99[~(~ 947`3 'C' - t •lolder's Name C t' V Ila,e Towlls-rp Parcel lax No. Krautlee Holding Company LLC VILLAGE OF ROBERTS 176-1086-40-100 CST RV CMv Ins? W C ev. Rhl Uescr ptic- Sect omTann.Rar e.tvll No /0O rA y 27.29.18.651A-10 TANK INFORMATION ELEVATION DATA TYPE MANUFACTURER CAPACITY STATION BS HI FS ELEV Septic - Benchmark z.7(o i6z.7 iall Dps ng Ci • An Bna Aeretticn g Bldg Sene• ::.o,.. Hooing SJ'Ht Inlet TANK SETBACK INFORMATION SUHtOUtet TANK i C P(L .VFLL Fl .DG. e: t •rfdn I-takc ROAD Of in'et Septic of Bottom Dosing ; Heado,:Man 3L, Z4 %D {5 r7 7 g Aeration Est Pepe y' S 5~. V5 Ho ding Sol. Sysicrr it ~I?•ZS PUMP/SIPHON INFORMATION Final Grade 3.5 99,45 fvtanufacwrn' Demand St Cover 8. 9 Nlcde' Numder 5~ ~4~ C ~-o,, r 6.9 95 • ~ TDH LJt~ Friction I-os§ Syslern Head I DH Ft f r 5 Fcr,:ernarn Length Dia. r I DA, tc wcu 1 SOIL ABSORPTION SYSTEM BED/TRENCH V;d:h Le-9:h No O_' '1_l PIT DIMENSIONS N^ 0'Ph nsme Dia tqua NCplr DIMENSIONS- ry.~, - SETBACK SYS TFN1 TO P.1 BLDG WELL LAKE3STREAAI LEACHING Ma: Va,-wer INFORMATION Y': r^: CHAMBER OR - 0 UNIT Model Mrmper DISTRIBUTION SYSTEM vi header9Aa•n'pd Jis9iou:icn Dom. xllCC Size Kllolo Spac ng :v"A-'nlav.o r P Po:s' le-9'h 2, lo7Cia Lengt- Dia Soacrg_ 3 SOIL COVER x Pressure Systems Only xx Mound Or At-Grade Systems Only Depth Cver / Cep'b live: XX Dep:h cl Xx Snetla. 7+SCaded ,A M,ICnel rteor I,vm-Cor'le• c 1 f f>e•5EC]P.5 ,5•-(3 d 1 ~"Q Pe5 L NO Yes I. _ No COMMENTS: linclide ccpe dscreperles, persons p,esort etc: Inspection ft1: 1 nspeyiign p2: Location: 1;44 7DTHAVC . - G~x Pf~ V 1.1 Alt BM Description 2 i Bldg sewer lengd• - amount of cover = v- a CdJlA- 7 L4,(r) OA_/ Plan revision Required? L Yes No Use other side for additional information I~__1__rb L ii x- ,,I,,.,,~_ Dale nsepctors Srgnamre en No I ~I '1 , L Industry Services Division 11 (tr,l. ai I ASP 1400 E Washington Ave - \vueny Permit Number (to be lillcd III br l"o I P .O. Box 7162 \ $ ' •I'I_ I _llli~~ Ali MadilUn, WI 53707-7162 i r I Y\AS, TI I (0 ?Z' 1 I $(111118,t'y PC.Clll It ApplIC3tIClil \r nu ll.nuauum Numhcr- - In a..oNaner tvhlf SI`5-\Si-?T 141'iv A l A , wbmi n ntlllu f' hn to the . it I, requited prior In btainml:..:nulan pennn \ r° ;\pphc Hole than. Inr >lale-owned I'MA IS are euhmi!li I" - u; Ikparfnm•'I ul Sati•w and I •ulessinnal [u, Ir.: 1'cnonel bt6•mtalron you pnrrldc Ina) be u.cd Inr .ccen~nl t. Protect Address (it Jillarent than mailin@ aJArc>.I pu oscs m a; duncenh the I'm ace I aw, > 1 sL41 I inn s. Mal,. 1244 70" .1vcnuc - I. Application Information - Please P lot All Information Pmlx:m'rhsnd• Name Per s~ _ ~ ~I cBuskcr' _ 16114',-i(i-Inn P•rpcll%Owler s Mvli1lg;1Jd JI/ ilQTT7;v • . 1196611" Awnuc Propene loca(ion f ,I. Lot Cut Stale Lpt (laic Phone Number \I . id \ non RI hens. WI "o23 sleoncl 11 type of Building lebeek all that apply) [.or a ❑ I or _7:uuJ, )welling -Numhcrad❑cJnwnts 1 vuhdniau.'. Nnux ubhu(lnnm r I,I Dcacnh I h;~ Jjloct t' _ t Cnp of L SIaIt Uwnnl Dscrihe . w El l, , I Q UIlave", Rebel >V1 Nuntbcr ~ ,cvti'0 _ 1 o1.~Pgt X03 Ll I own of III Tvpr of Pernrit (Check only line bus on line A. C'omLete line B if a I I icabfe~ tie qrm Rrylacsmnn St'stan - l reallueni. I h:ldm•,I Tank Rel'I'tw 11I link ❑ Other MOdillca KIII W I:aku System (explain: B. ❑ I'anul Kencwal ❑ Permit Rcri>iuo: ❑ I, hmtge of ❑ Permit hander m New IJat Prcelnlw Permit Number H ( late I» eJ r ' - - - ; , dittc I'xInrnu n umber lJsener - _I 1rr I V. vp of POW I S S-vslem+'C•onl unen1. Devicc: (,Check all that appl) ) Non-I'rassnlial In-( round ] I-res.nnnd In-(,rremd ❑ Al-Grade ❑ \hnmd .2.4 in. nl witele snil Ntuund 24 in ofsmlable wil I :Idle: lank ❑I)tit.r') m,l -n: Icsplaini -]P::Ircat^att Dsvi.e fcVpla:nt V. Un xsmV reahnent Oren Infmnlanun lk I n i I n, Ieild! I>t I S Il 4PP1i 1111 Uspenal 'A ea Kcyui¢d (x11 DI l sal Area Prup,,ed tsl) Atclem ,euun IAI IJ>C 1 ili e ~ Le .e14 ✓ 19 .19' r NT lank Info Calm in (I JI nf> r - ae IJ of a G,illan> Lnit r 41mutl slurcr _ Vew I'mtk> I sisam~ l::nks I n 2 . Z Z z' Scpve cr H.wme Tuh tigi lass I VA ls:er(enlsr.~/] ❑ ❑ I ❑ J 1h, nn lhanthel gin 951p j I ll l: ssr l oue'ele - Z _ ❑ ❑ VII Responsibildy Statement- [,the undersigned, assume rr. ponsibilis fur innodlation of lbr PO\x fS shown un the attached pints Plums - Name I I ow I'l;:mbvf _s line Nil, .'Nil R \w0i:r i snc.s Phone Number John 4hnlilt - Z~2 i<i~~ ' " • -j(_.~ 7 71i 760 (u86 !'lunihu s Add7e.> r1tn.U City. \tatc. lip C,-dc I ~ _ - - - _ 616 I'll I ;Ave. Somerset, M 54025 A'lll. (bun( Dc rrctment Is_ a Only - o-m t t \.pureed ❑ DI. :paro, I'en it Fee ~e Date IaucQ 1»T lime apenl Gyjt elute C.~~) II I n\na G!e n -0 a+on titi Ocnia ~ I0. l r IX. Cnndi u 1 ea. n> her Disapprnyal I~,~t f t wymr.IS, 4 Mm eA tj' R'rdt r% !•f 'P ` as per mw ayerrteM piEn yv risen Lv VlwTIM. 2 AM ee!hv* relnt .ens mIr t lie. rart'r.E : : r 1.1. A IIIh In anmplcre pile M, the s, \Irm laid obrlft In flue/mint. nnl mpaprr nM lc,, than ar!s 11 imh, in site ! PLOT PLAN F>roject Name: LBM 750 gallon per day Mound Septic System Lega' Uesc:IpLOC. SE1/4. SWIM, S27. T29N, R18W P.L: -Part of 176-1086-40-001 Subdivision Nams- NA Lotk TINA - - Vuge. Roberts Parcel S2- 110 Acres SCALE- 1^ = so' Li County' St_. Croix Contour Line _levatlon. 95.86 l- Dimensraas.'8X 93.75' a mch 5-h at -.asi G25t5 System. Elevation 97.19 bAound Dimensions 3- x 2.4.32' 2 inch S..h40-ASft4V 82 Slope 2 ' V2 Scn 40 -r 571,1 ~1TAS _ A, ;;M1 Elevation 1100.00' lop of 2" PVC pine Bh1r Clevalion: 100.35_' Tnp of ' F1,P pipe ■ BacKbaePas. Septic Tank 1585 gallon Septic Tank wi POLYLOK 525 Efflunt Filter_ ~osc -rnk: 950 gallon Dose Tank W 1M 1 I t ~ I I r1 (~6 ra ~ f l~ t~a LI LsN j11A-/C(-%" O O i I Sic 34 1>? .ic rib C/i.~-L L I H 11H j?~L.~I+Sc 1) I ~rllvw SPS 3t2-;q 1 oa 5ox! I'~ ~N 17i6J o~~ ~K; DIVISION OF INDUSTRY SLRVICES Sa24 CRFFKSIDL LN HOI MEN W 154636-A4fiG ` 0 - DOntae: I hruugh Relay SP http':'asps.wl.goy:programs:exfaetry Services wwvr wlsconsin.gov Scott Walker, Governor Laura Guti6rrez, Secretary September.'1, `017 ('US'I ID \o. :?()ll . ITV: 1101IF7.S Llspecla JOHN F SCH\11I I ZONIN(i OFHC1. SCHMIVT h SONS FXC A\' \TING Sl CROIX COUN Il' SPIA 016 1`0111 AVI 1101 (:\RMICIIAI(1. RD SONIERSL'I WI >4039-6920 HUDSON, \A'I 91016-7103 CO\DITIONAI.:APPRO\ %I. - Identification PLAN APPROVAL LXPIRES: 09.'2U2019 473 Transaction ID No. 2999)?3 SI 1 L: Sitc ID No. 392661 [,but Slone Please refer to Iwth identification number,. '11111 Ave above- in all correspondence with the Village ui Iii+bert. agency. St (I (cxuny SI<1:4, MI, 14, S21, I'29N. RIM FOR: Object hype: PO\\1S Component Manual Regulated Object 11) \o. 1"6441 Maintenance required- -50 GPD Flow rate: Sysfeni(sl: Mound Component Manual - \'er. 2.0. SIM -10691-P IN.0101. R. 101'). Presurc Distribution Component Manual - Ver. 2.0, SBD-107-06-P(\.0101. R. 10.'12): Commercial Sv.lem, Ltllucit Liller Ili; submittal described aline has been reviewed tiir conformance with applicable Wiseon,in Administrative CeJes and \\'iscumin Statutes. The submittal has been C ONDITIONALI:1' \PPRO\'LD. I li s)stcm is to he constructed and located in accordance wilh the enclosed approved plan, and with any component manual(s) referenced above. The owner. as delined in chapter 101.01(10). iscon in Statutes. is responsible for compliance wish all code requirements. \o person may engage in or work if ph nthing in the stale unless licensed to do so by the Department per s.l d>.06, stay. I he following conditions shall be met during construction or installation and prior to occupancy or use: • The discharge of hacardous waster to a private sewage system is prohibited by state and federal rceulzwons Accidenlal discharge of an\ hazardous substance io a private sewage system most be reported to d:c Ucparlntenl of 'Natural Resource, (\VDNR) or the \\'isconsin Division of Fmcrgency Government. • This k,tern is to he constructed and lo"acd in awcordancc with the approved plans and with file "Preswre Distribution Component Manual ter Private On,ife \\asfewatar1-rcatincnt Systems Version .O" SBD-10706- P (N.01!01). • This system is to be concl rutted and located in accordance ,eith the approved plans. and file "Moo tid Component \lanual for Ih ivate Onsite \Vaslewater Systems Version'_.0" S11I)-10691-P(\.01:01 L • 1 be pressure network is to he constructed in accordance with publications SBD-l0?06-p(\0101)"Pressure Di,tr i but ion Component \lanual fur Private Onsitc \\4tstcwater Neat ment S\,lenu - Version 2.0" and or the ,icing methods of publication "SS\N MP Publication 9.6 Design of Pressure Distribution Networks for Sf-SAS 101 t31)". A copy u1 the approved plans, specific:n ium and this Inner shall hr on-siR. during construction and open to in,nection hg :rulhoriied repre:attafivcs <~1 :hc D:parom,m, whidt may in, II d .:oval inspcclor,. \;I IN •rmn, Jf HIA FSrllhil.l p.,o;.'_ vC.!_..C regaired by the state or the local munieipalily shall tv obtained prior to commencement of construction installation ollem ion. In grantingg thi, approval the Division of Industn Services reserves the right to require changes or additions should condition: arise making them necessary Ibr code compliance. As per state slab nolhinc in this review .4ner of the responsibility for dc,icning a sate building, structure, or component. shall relieve the Jcsi. Inquiries con:crning this correspondence may tx made to nnc at lte telephone numhcr listed hclow. or at tltc• address on this letterhead. The above ]ell addressee shall provide a copy of thi, letter and the POWI S management plan to the owner and any others who are responsible for the installation, operation or maintenance of the PO\\~ FS. Fee Required $ 250.00 Since 1%. I hi, \mount Will Be Invoiced. \k hen You Receive That Invoice, Malthcw Allen Janzen P1casc Include a Copy With Your Waslew;tlcr Spccialisl . Division of Industry Services Payment Submi0al. (71 j 10-0 to' . W iSMART code: 7633 nnatthew janzenra"isconsin.gov _ MOUND AND PRESSURE DISTRIBUTION COMPONENT DESIGN INDEX AND TITLE PAGE Project Name: LBM Stone Mound Owners Name' Luke Busker Owner's Address P O. Box 180 Roberts, WI 54023 Legal Description SEV4 SW114, S27. T29N, R18W CONDITIONALLY Village: Roberts APPROVED DEPT OF SAFETY AND County St Croix PROFESSIONAL SERVICES DIVISION OF INDUSTRY SERVICES Subdivision Name NA Lot Number. Block Number SE bftn£ UiDE NC Parcel LD Number Part of 176-108640-001 Plan Transaction No Page 1 Index and title Page 2 Gallons per day and tank size calculation Page 3 Data entry Page 4 Mound drawings Page 5 Lateral and dose tank Page 6 System maintenance specifications Page 7 Management and contingency plan Page 8 Septic and Dose tank specifications Page 9 Effluent filter information Page 10 & 11 Pump specifications and curve Page 12 Plot plan Page 13 Septic lank maintenance agreement Page 14 Warranty deed Page 15 CSM Attachment Soil evaluation report Designer: John Schmitt License Number: 223760 Date: 9+412017 Phone Number 715-760-0486 Signature Designed Pursaant to the Mound Component Manual for POWTS Version 2 0 SBD-10691 P (N. 0'.:01) and bosh SSWMP Publication 9.6 Design of pressure Dstnbu1ion Networks for ST-SAS (10181) and Pressure Distribution c<nnponcot Manual Ver 7 0 SBD- 10106 P :N 01,011 Version 7.0 (R. 0312012) Page 1 CALC ILAIlOfi OI• GALLONS PLR DAV AVf) [AN K SIZE For LUKE BUSKER V1ASONRN (Proposed Shop Building) I he septic system will serve a proposed shop building for Luke Busker Masonry, ronsistinc of 70 rmplo~cc :u:d 8 Iloor drains. The 8 floor drains \N ill be for domestic wa,tc\+atcr. Ah other I] oor (iram, m H he directed to a non-tiomeStie wastewater holding tank. Luke Busker h1asonrN (Table A-383.43-1) 70 5mplovccs 20 X I GallonsDav - 760 Gal Ions Dav 8 floor Drains 8 X Gallons ; Dav '_'00 Gallons 1 Dav I At a 40 Gallons Dav Tolal - 500 Gallons / Dav Dc,iun 1 ions 'm fable A- I >OO X 1.5 -750 Gallons Dav Daily \Vastewater Flow = 7-50 Gallons/DaN 1'0\\ I S hreatment Tank Capacity Minimum Tank Volume- IAT i (11.0 gallonsperson. daN N car s fAT 75 gallons+''day s 3years) 4 (46.77gallons s D\VF : 75 gallons/day) - MininumtTank Volume-750 i (I1.61gallons+'persotvdavl Cars Till : 7,gallons/(la\ s years) - (46.77gallons 750 75_allonsrduy) 1566gallons Minimum 'lank Size = 1566 Lallons Proposed Treatment Tanks Proposed Septic Tank- Wieser Concrete WLP 1585 950- MR -1585 gallons Total Gallons or Treatment Tanks = 1585 uallons Page 2 Mound and Pressure Distribution Component Design Dr_ Site information C Residential or commercial Design nNote Sand011 (D) raiwlafions assume a e 30344-3 in-situ soil tteatment for 500.001 Estimated Wastewater Flow (gpd) fecal conform of 36 inches. 1.50' Peaking Factor (e.g. 1.5 = 150%) 750 00 Design Flow (gpd) 2.00 Site Slope 95.86 Contour Line Elevation (ft) 20.00 Depth to Limiting Factor (in) 0.60 In-situ Soil Application Rate (gpolfe) Distribution Cell information 93.751 Dispersal Cell Length Along Contour (ft) = 8.00 Cell Width (ft) 1.00 Dispersal Cell Design Loading Rate (gpd/ff) 1, Influent Wastewater Quality (1 or 2) Are the laterals the highest point _ in the distribution I _ Y network? Enter Y or N Pressure Disribution Information C' Center or End Manifold 2.67 Lateral Spacing (ft) if N above, enter the elevation (ft) 6 Number of Laterals of the highest point 0.156 Orifice Diameter (in) 2.50' -,t mated Orifice Spacing (ft) = 6.94 fe/orifice 2.00 Forcemain Diameter (in) 100.00 Forcemain Length (ft) Does the forcemain drain back? Y Ente'•' r,r f! 89.00 Pump Tank Elevation (ft) F----47575] System Head (ft) x 1,3 M58 Forcemain Drainback (gal) 1.86 Vertical Lift (ft) 5x Void Volume (gal) 6.60 Friction Loss (ft) Minimum Dose Volume (gal) 0.00 In-line Filter Loss (ft) System Demand (gpm) 19.01 Total Dynamic Head (ft) jin.dia Ffion-schoice Manifold Diameter Selection in. dia. options choice 1.25 _ 0,75 1.50 x 2.00 x 3.00 Gallonsllnch Calculator Icl-,i Treatment Tank Information ! Total Tank Capacity (gal) I Total Working Liquid Depth (in) 0' Septic Tank Capacity (gal) ` allin (enter result in cell B49) , Manufacturer l~J 9 Wieser ser Concrete Dose Tank Information Effluent Filter Information 9.50.00' Dose Tank Capacity (gal) POLYLOK Filter Manufacturer !Filler Model Number 25 00, Dose Tank Volume (gaVin) 525 Wieser Concrete Manufacturer Project LBM 750 gallon per day Mound Septic System Page 3 Mound Plan and Cross Section Views -T JI ,,tion Pipe - #1!10 B 0,4 l K _A i L Mound Component Dimensions 1.00 ft K 9 62 ft A 8.00 ft E 7 92 in H T F- 8 89 h L 112.98 ft B 93.75 ft F 9 50 1n W 24.32 ft 7 43 ft G 0.50 It j D 16.00 in 1583.28 (ft) Basal Area Available 750.00 (W) Dispersal Cell Area g 38 (ft) 1110 B Obs. Pipe Placement 8.00 (gpolft) Linear Loading Rate Mound Cross Section View Aggregate Dispersal Area Finished Grade 98.99 (ft) _ G * 1 H 97.69 (ft) Lateral F uisPo- rsel cell invert I 97.19 (ft)---► II t Dispersal Cell E D Q ji. Elevation ~y<r~ Q ~ 86 (ft) Contour Elevation 2 0 % Site Slope Geotextile Fabric Cover o n -IT- Dispersal Cell See lateral details on ~Shading Key page. 4 for number, size. Topsoil Cap .2 c 1.5 ft and spacing of laterals. V Su050i1 Cap A II°. :a Laterals are equally 7 e F spaced from the ASTM C33 Sand 10.5 ft Tyolcal Late a1 1 distribution cell's Tii{ed Layer c H I centerline in the yT' Aggregate ° o -i- distribution cell (AxB). Project: LBM 750 gallon per day Mound Septic System Page 4 Center Connection Lateral Layout Diagram LaalaL +r«i•Semw al anrpoK'•' ~ For<«rt.an•:•inr,r.:ri•:n crf ree or acss to mamk>IA at 4v--. S -_P= - y •=Turn-up'x.>•GHII Valle 4r IEX-'-'I'`xR~,1?+I Latet013 firC('ff,a'rt SCh 40 PVC of ea neut plug per SPS Tat.--le .,A 305 Hole: AnIkA n rlw tavom of the lar«raf Orifice Diameter 0.156 In 6 Number of Laterals 2.64 `t Lateral Diameter 1.50 m Orifice Spacing (X) 18 Li9o ft Orifices per Lateral It Orifice Density 6.94 ftzlonfice Lateral Lateral Length Spacing (P) (S) 5.33 ft Lateral Flow Rate gprn Manifold Length 2 00 in System Flow Rate opm Manifold Diameter 5.94 in Total Dynamic Head It Forcemain Velocity Dose Tank Information erking cover with warning _ label and locking device and ~-i sea'eo watertight Electrical as per NEC 30C and 4 in. mm. SPS 316.300 WAC Disconnect E-- Alternate outlet Tank component is properly vented location Forcemain diameter 2 in. Wieser Concrete 11 Manufacturer _r Capacityl 950.00 Gallons A Volume 25.00 Pull , weep hole or anti- siphon device Dimension Inches Gallons 8 A 2026 506.52 C 2.00 50.00 Punt off elevation (tn B 89.83 C 5 74 143-48 D 10 00 250 00 D Total 38.00 950.00 - Dose tank elevation (it) 89.00 -I---3Y" Bedding un er tank. l Note S~litches Alarm Manuafacturer SJF Rhombus 1 containing mercury Alarm Model Number 1036378 may not be used in - ~ . Pump Manufacturer Zoeller, this system Pump Model Number 1 140 Pump Must Deliver 58.16 gpm at 19.01 ft TDH Project: LBM 750 gallon per day Mound Septic System Page 5 Mound System Maintenance and Operation Specifications Service Provider's Name John Schmitt Phonel 715-760-0486 POWTS Regulator's Name St. Croix County Zoning Phone 715-760-0486 System Flow and Load Parameters Design Flow - Peak 750 gpd Maximum Influent Particle Size 118 in Estimated Flow - Average 500 gpd Maximum Maximum BOD5 TSS 150 220 mg1L mglL Septic Tank Capacity 1585 gal Maximum FOG 30 my1L Soil Absorption Component Size 750 ft' Maximum Fecal Coliform >10E4 cfu/100 mL Type of Wastewater Domestic Service Frequency Septic and Pump Tank Me r service once eve 3 ears aandd clean at eveeace eve 3 ears ce lea3t n a' Effluent Fitter onC' a Pump and Controls ould test month) Alarm Pressure System hed and ressure earMound and seepage once every 3 years Miscellaneous Construction and Materials Standards 1. Observation pipes are slotted and materials conform to Table SPS 384.30-1. have a watertight cap, and are secured in as shown in the mound component manual. Adm . Code. 2. Dispersal cell aggregate conforms to SPS 384.30 (6)(1), 3. All gravity and pressure piping materials conform to the requirements in SPS 384, Wis. Ad m. Code. 4- T,Ilage of the basal area is accomplished with a mold board or chisel plow 5. The mound structure and other disturbed areas will be seeded and mulched to prevent soil erosion and help reduce frost penetration. Lateral Turn-up Detail Finishes ,,.•.Grade 6 Threaded Cleanout -8" Diameter Lawn - - Plug or Ball Valve Sprinkler Valve Box Distribution MgSweepgOorTwo _y Degree Bends Same Diameter as Lateral Project LBM 750 gallon per day Mound Septic System Page6 Mound System Management Plan Pursuant to SPS 383.54, Wis. Adm. Code General This system shall be operated in arcordance with SPS 382-84 Wis. Adm. Code, arc shall maintained a accordance with its' component manuals (SBD-10691-P ill 01101, R. I V 2), SSWMP Publicatior 9.6 [01181), and P,essure D~stribulion Component Manual Ver. 2.0 SBD- 10706-P IN 01i01 R. 10+121] and local or state rules pertaining to system maintenance and maintenance reporting. No one should ever enter a septic or pump tank since dangerous gases may be present that co cause death. Septic and pump tank abandonment shall be in accordance with SPS 383 33, Wis. Adm. Code wh hen the tanks are no longer used as POWTS components. Septic or pump tank manhole risers, access rsers and covers should be inspected for water tightness and soundness, Access openings used for service and assessment shall be scaled watertight upon the completion of service. Any opening deemed unsound, defective, or subject to failure most be replaced. Exposec access openings greater than 8-inches n diameter shall be secured by an effective locking device to prevent accidental or unauthorized entry into a tank or component. Septic Tank The septic tank shall be maintained by an individual certtred to service septic tanks under s. 281 48, Stars. The contents of the septic tank shall be disposed of m accordance with NR 113, Wis. Adm Code. The operating condition of the septic tank and outlet fitter shall be assessed at least once every 3 years by inspection. The outlet filter shall be cleaned as necessary to ensure proper operation. The filter cartridge should not be removed unless provisions are made to retain solids in the tank that may slough off the filter when removed from its enclosure If the filter is equipped with an alarm, the fiter shat be serviced if !he alarm is activated continuously. Intermittent filter alarms may indicate surge flows of an impending continuous alarm. The septic, tank sha11 nave its contents removed when the volume of sludge and scum in the tank exceeds 113 ;he I,qu'd voume o the tank If the contents of the tank are not removed a1 the time o` a tnenr l assessmert .mairtenance personnel snal'. advise the owner of when the next service needs to be performed to maintain Less than maximum scum and sludge accumulation in the lank The addition of biological or chemical additives to enhance septic tank performance is generally not required. However, if such products are used they shat be approved for septic tank use by the Department of Commerce. Pump Tank serviced as necessary mps shall be tested to verify proper The operati n. If an effl effluent tank filter shall s nsta I d within tat least once every 3 years. he tank it shal, be rspected All Mound and Pressure Distribution System No trees or shrubs should be planted on the mound. Plantings may be made around the mound's perimeter and the mound shat: be seeded and mulched as necessary to orevent erosion and to provide some protection from frost penetration. Traffic (other than for vegetative maintenance; on the mound is not recommended since soil compaction may hinder aeration of the infiltrative surface within the mound and snow compaction in the winter will promote frost penetration. Cold weather installations (October~February) dictate that the mound be heavily mulched as protection from freezing. Influent quality into the mound system may not exceed 22C mgll- BOO,, 150 mg+L TSS.. and 30 mgfL FOG for septic tank effluent or 30 rngf - BOO„ 30 mg/L TSS, 10 mg7L FOG, and 10^ cfu1100 mL for highly treated effluent Influent flow may not exceed maximum design flow specified in the permit roc this installation The pressure distribution system is provided with a flushing point at the end of each lateral, and it is recommended that each lateral be (lashed of accumulated solids at least once every 18 months. When a pressure test is performed it should be compared to the initial test when the system was installed to determine if orifice clogging has occurred and if orifice C,earng is required to maintain equal distribution within the dispersal cell. within le 0 ssaboveo6 inches conthe dispersal dered as an imparting hydrauc failure requiring additional, more frequent monitor o9 ed to fne owner, an any checked for effluent Contingency Plan if the septic tanK or any of is components become defective the tank of component shall be repaired or replaced to keep the system in proper operating condition. V! the dosing tank. pump, pump controls, alarm or related wiring becomes defective the defective component(s) shall be immediately repaired or replaced with a component of the same or equal performance L• the rnound component fails to accept wastewater or begins to discharge wastewater to the grouno surface. it will be repaired or replaced o its' present location by increasing basal area if toe leakage occurs or by removing b media and related piping, and replacing said components as deemed necessary to bring the s ystero into proper operating condfron pe sal See Page 5 of this plan for the name and telephone number of your'ocat POWTS regulator and service provider Pretreatment Units merail and The and Soi tcr uni s a•efattached as sepa rate docume is agnd aeetco siderled part of the eve ala'.tmanageme t d an for his sbystemitnent units or dssmfecLUn Project. Page 7 ru '851d1.1 3lIJ ' - fi C ci oIVI r';ta, x a~oa a • n lVf1NVW OI1d3S 3~<S i'rL ua ra~~raa 313HOHOU B3531M C'\ 056/989ldlM C. LLJ vxwi p ~ J 'U H Q W J N co Q _ O w U z a F o N a o O a wa a N Q ° O ~o~ a w a u n w U o~Q z? co o z w o> ur) LL 00 U apdodo 900 m ~ww uu w z i~ Y Q& o Ul W n o") J w on o_ N o z Q c °,v \in i7 `ap ri of a QwV1 p ¢ x F a- v) N mw N V a ?j M. Nn'n r w~+aowa ~2E T w w u o~ Yr Y bw~^oZw ~u~r ENV) r z J ~F 'n~ a~ Z ..0~ ^3oJ~~oa ooz w ¢ w m p w °o ou G ..0~ UT a vOQZo a° v o a N o s do Z3mU~2 J~mJ53 1WJ ° Z U WKW O w J a z w z N J O Z 2 CY OJ < O-C U U r„Ib ti 1 - _ II i II, I w 11 ~ I I i II ~ II I o I I I I O II II I N N J. 5 S II a OI I Li o II II. II Y.•. II I U I i lK i `r I a I ~ / ~ III I. ° i z a w w J a oo~a' tb _ Y p Z Sli Page 8 OA 1'1 -~)25 FIFfluent [ iltcr ,atUro rn vm:ast L'+aina~e ,~;yr, T.:1>_•i filter I he P1,525 Filter is rated for 10,000 GPD (gallons per day) making it one of the largest filters in its class. It has 5251inear feel of 1/ 16" filtration slots. Like the Polylok PI: 122, the Polylok PL-325 has an automatic shutoff ball installed wilt every filter. When the filter is removed for cleaning, the ball will float up and temporarily shut of t the system so the effluent won't leave the tank. i!I!r 1 Rated for 10,000 (;PI) (gallons per day) (optional) 10,000 G] D) 521) linear feet of I,•']6" filtration. Accepts I" PV(' h Etlertsum Accepts 4" and G' SCf II) 40 pipe. Handle Built in gas deflec lor. :Aulomatic shut-off ball when filter is removed. _ ItaM1•al for Warm accessibility, I(L(xxt GPD Accept% PVC extension handle. t, In.l.tllatitm: • X25 Linear Ft. Ideal for residential and commercial wasio flows up to ice=` „r t/tn'. 10,(100 ,allons per day (G VD). 1. Uwate the outlet of the sepl is tank. 2. Remove the tank cover and pump tank if necessary. A..•pt` k t: 3. Glue the filter housing to the 4" or G' outlet pipe. If SO In au pipo the filter is not centered under the access opening use a Polylok Extend Lok or piece of pipe to center filler. 4. Insert the fit -535 tiller into its housing. CertWed to 5. Replace and secure the septic tank cover. NSVANSI Standard 46 I'I \Iei Ale. n,n L Ihe PI.-525 Fflluent filters w ill operate etficiently For several years under normal conditions before requiring cleaning;. IF is recommended that the filter be cleaned every time Ilia, tank is putnpod, or at least every three years. If the installed filter contains an optional alarm, the owner will be notified by an alarm when the filter r`- (,as Defhrh,r needs wrvicing. tierviciny, should be done by a certified ` :Nulnmati, septic lank pumper or installer. Shut-Off Bail I. Locate the outlet Of the septic tank. 2. Remove tank cover and pump tank if necessary. 3. Do not use plumbing when filter is removed. 4. Pull PI 525 cartridge out of the housing. - 5. l lose off filler over [he septic tank. Make sure all ,M►I solids fall back into septic tank. ~J 6. Insert the filter cartridge back into the housing making sun, the filter is properly align ed and completely insert'(]. I olVIC* %ata,l fi )lost filters a•pI Easiiv installs Ihe SmdriVill,r-, ••a'itch aml alarm. into erejlnr tanks Replace and secure septic tank cover. Polylok, Ise. 3 Fairfield Blvd. Wallingford. CT 06492 '1]111 Frca 87%.765.9565 lac: 211.3.284.8514 www.polylok.com Page 9 SECTION: 210 045 r 1,,1 12 1/7JL /TY PU1NP5' ✓~N.! E _ _ Z O 1211 / /i i~ 0 $uDxrsodes f i.::f..'.a infcrn'X1or prexeea 0710 h,ir"L`P:IS Cnr.d 11005 A11119C , 1 [I alir:o. ~.r5rlt factory iu iy:: >C CC ncCS Cr VISIT our web site: ~m~ isi I.mri > I MAIL 70: FU. BOX 16347• tO(.iFm1iV, KY 40156 0347 www.zoellefcom om SHIP T0. 3644 G.!r. V611 Road • L0111SIM" KY 40211 '461 {51)21776 17:11. 11600! :,28 PU'MA' • FAX (502, .'74 V;/4 14014140 & 145/4145 Cast Iron Series Durable Cast Iron construction (For Pump prefix Identification see News 8 Views 0052) -Clogging engineered rdodel 140 features a Non mermoplastic vortex impeller design and passes % spherical solids Vedel 145 features an engineered thermoplastic single vane impeller design and passes spherical solids FOR SEPT IC TANK - LOW PRESSURE PIPE (LPP) Motor-n0 Hz. 3450 RP61. oil-filled, hermetically AND ENHANCED FLOW STFP SYSTEMS sealed, automatic reset thermal overload protected EFFLUENT Available in Loth single or doable shaft seal designs Carbon..iCeramicmechanical shaftseals OR DEWATERING PUMPS SUBMERSIBLE Assembled with Stainless Steel bolts 11/,' NPT DISCHARGE Stainless Steel lifting handle upper sleeve and lover ball bearing running in bath of ail 23 If UL Listed Neoprene cord with molder plug cap _ .w and ground wire Pi. . L.Mil lid 1*4` NPT vertical discharge BN and BE models include a variable level floal (..°y switch and 1 X 2" PVC adapter fitting 1 Operates at temperatures to 130'F (54'C) in eftluer.l t r or dewatering applications Corrosion resistant powder coated epoxy finish uc y- t ar ti. Note: The sizing of effluent systems normally requires - variable level float(s) controls and properly sized barns to achieve required pumping cycles of dosing fimers hilh nonautomatic pumps. SP 5 oil POWDER COATED MAIL TO: P0. BOX 16347 TOUGH' .allrrr 1 et ,vu KY 4025,5 0341 SHIP rO 1641. Call Pnkoa^ ~ - 11 su,e KY 492 :ht 5i 2 ! A 1'1! 1 iilk 18;JMr' - - rAX519M.74 3614 t • te4tomAtlcihlcd,ds DG! d hl) • Nay;utunAtie , Manufacturers of • I4P, IPh 115V of 230 '141DA140) O r{P 1Ph 11 5vl14ti4•4sl ~ o T7 ~7p QUQ//TY PGNPS ,j/NCE /9~/. / Copynght 2011 Zoeller Co All rights 1aselved. Page 10 I OTAL DYNAMIC HFACTLOW C T: ra~uo=1 n=crluavc* cdavF PER MINUTE MCDEL 14Qz14o•4504j45 EFFLUENT AND DEWATERING _ MODEL 1404140 145!4145 hrr Netan IBers d. Lrtr t- "~7I _ I 1 125 1 9?2 fr rrr+t~', '111 ra i s 48 i 23 21 GJ 3 6. r • 1 n~ v I~ r5 6 SB p, 6.1 05 9 zo, 50 5] 201 1e ° ` IF 25 ]5 +9 ilJ 49 I66 hl ~T y0 2 1 155 45 lit 49 I~ 4n 12.2 2e 1E 105 15 ,U f 59 t_ 2 _ 26 90 yam'. 1111 15.3 15 " `J rt ~ $XUbX II..aO. :A 911S1m1 l4 X 122.&,11 _ JII L. ~I ' ~ III. I ` 4 7!; I 11 ~ 1 L 'JCY ~ I n oltMPnwni 1111 \W JJJ°°° l I-- tLr6 • Eccuical altemmors for duplex systr:ms, are available and supplied with an alarm. • I 1 •har.lcal alternators, for duplex systems. are a5alable with rx without alarms. - I ~ r•dn4 alann svstems are avalaule for t obase pumps used in simplex system, Sce F1,40732. r^F - ~ x 1b ~ arable Irvel control sellc'aes are avaaahle fol controlling single phase systems. n srhle plegybaO.. variable level finat swilchos are available for variable level long cycle controls ~ l ilod Owik Box avadanl-~fur outdoor Ins allaOr s. See Rd1420. • Fe4-~r to FN1il8(ic 'or a0f' canons aoove 130"i' i:,4' Cj 14014140 814514145 MODELS • SINGLE PHASE Control Selection w Model Model Volts Mode Amps Simplex Duplex N14C N414; 115 Ncn '2 tort 5 -14C E414r, 230 felon i; 1 it2 eF.140 814414C 115 At.to 7 ~ B['40 3E41,t0 230 A.utn 6 11145 N414!, 11S Nn T, 13 1 or 2 3 _t_.. 1146 E4145 230 Non (1 ' 00 3 - BN145 B14 1-15 11:, Auto 13 - BC14L 5E414b 231) ,~:afo p, •si9.le pIIcyhack. switch Indu IrI 1. For automatic use single piggyback variable level float switch or double piggyback variable level float switch. Refer to FM0477. RN,l~rrs pclelU<' .cuyl u, by Jebrs. ~ Ala-es rr ~ or barks ~nJer the ou •p ' 2. See FM122t3 for totted model of simplex "Easy assembly" control panel. I I.,Je ofduablE oor= sve ABS. e~ ,Nrmy Jmcr,ry. voe Raises pump 2 uff bottom of rash <I3. See FM0712 for correct model of duplex Provides the ability to rase intake by adding control parcel. srctions of 11W or 2' PV(, Aping. 1 ~j1{,. o cnurf~ miaches securely m pu. p. , Accc~nmodates sump, devalering and •tll:^rt applirat pr's. NOTE: Make sure float is tree from obstruction. - nit un.ISUaI r;:ndr on; s reserve safety factor is engineered into the design of every Zoeller pump. _ i~opyri~ht 7Ui 1 Zcellal Co. Ni nyhts e.wrved Pate 11 PLOT PLAN N Project Name: LBM 750 gallon per day Mound Septic System T Legal Description. SE114, SW114, S27. T29N, R18W P.I D-FPart of 176-1086-40-001 I Subdivision Nana NA I of #..NA ~ SCALE: 1^ = 60' Viliage: Roberts _ Parcel Size 10 Acres - Coun 1' St. Croix Contour Line Elevaton 1 95.86 : ell Dimensions 8' X 93.75' 4 mcn SCh 40 -ASTnt J2665 System Elevatio - 97.19 Mound Dimensions- 113' x 24.32' 2 1,10 SCr•. 40 -AS I V DI7d5 Slope 2 _ . t7 S_h 4C -f S7t 1 1785 8111 Elevation: 100.00' Top of 2" PVC pipe • 81.12 Elevation: 100.35 , I op 0 2' PVC pipe ■ Backhoe Pits. Septic Tank 15 85 gallon Septic Tank_ w1 POLYLOK 525 Efflu_nt Filter Dose lank: 950 gallon Dose Tank \ 1 C LJ I ~.iCON`T UFtZ 1 of N_E LL li gi ~ I Z'~• P11RktN(i tCT 4 f s ~ BL ~~Lc55Hkv t c C t-`Z~c 1 I 00w') 1W7950 a o sePiic~JC. ~ I ~(c 39 SS 1 I rAti I pl Cc dCSc 1) L8h1 si+~'F 1 5r ti~Jd~uh'on ~ 1 ~ ~(!vw SPS 3E23~ ~ ~ ~ c` 7-54.4.w,SS'.titk 7 Qr~QrINC Lc oa d.F! h`` I p? t-I ri R 6~ a e ST. CROIX COUNTY SEPTIC] MAINTENANCE AGREEMENT AND OWNERSHIP CERTIFICATION FORM Owner,11tivei LBM Stone & Fabrication Mailing Address 1196 60th Ave. Roberts, WI 54023 Property Address 1244 70th Ave. Roberts, W1 54023_-,I--N) (\'cri lianion required from Planning & /onmg Department fur new COnalruclion.) City/ State Roberts, WI Parcel Identification Number 176-1086-40-100 LEGAL DESCRIPTION Property Location SE SW '/4, Sec. 27 . T 29 N R 18 W, Town of Warren Suhdivision Plat: - Lot # 1 Certified Survey Map # _ Volume Page # Warranty Decd # - - (before 2007)Volume Page # Spec house ❑yesEho Lot lines identifiable oyes❑no SYSTEM MAINTENANCE AND OWNER CERTIFICATION Improper use and tai n[enance of your septic system could result in its premantre failure nm handle wastes. proper maintenance eonststs of pumping out the septic lank every three yeas. m' sooner, if needed. by a licensed pumper. R'trai you put into die system can aflect the function of the septic tank as a treatment stage in the wasted isposal system Ossrmer maintenance respunsibi lit ies are apect ficd tit ¢S PS. 383.52(1 ) and in Chapter I'_ -St. Croix County savory Ordinance. The property owner agrees to submit to St. Croix County Planning s Zoning Department a certification form, signed by the owner and by a master plumber, journeyman plumber, restricted plumber or a licensed pumper verifying that (1) tire mr-site wastewater disposal system is in proper operating condition and or 121 after inspection and pumping if necessary!), the septic tank is less than I;3 full of sludee. Uwc, the undersigned have read the abuvc requirements and agree to maintain the private sewage disposal system with the standards set forth, herein, as set by the Department of Safety And Protessional Services and the Department of Natural Resources, Stale of Wisconsin. Certification stating that your septic system has been maintained must be completed and returned to the St. Croix ('ourm Planning K Zoning Department within 30 days of the three year expiration dale. I ,se certify that all statements on this form are true to the best of my.our knowledge, I~ we. am/are the owner(s) of the property described above. by virtue of warranty deed record • in Registcr/m(Dccds Office. , Number of bedrooms r! K f 07,211 is SIGNATURE OF APPLICANT(S) D.ATF. Any inhumation that is misrepresented may result in the sanitary permit being revoked by the Planning x Zoning Department. Include with this application a reccndcd Aarrant.\ decd from the Register of Deeds Oitice and a cops' of the certified survey map if reference is nctdc in the warrant% decd. (REV. 04A 2) Ott h~~s~a ?I 1111 !l u~i l~_-)LUG' i i •{yHO~. d ~1il~! •I Il , D. V. t I 1 I I Imo. NDI 3G i J 4 Y 1 • r . 4 r - 1 3 ~ i ~ I IU rzn F<.y, ~~...ccn; v.cS If I ~ Y~ ,y fJ~~~~uoDe~uge~gouo3S W9lJ~ ~.,ii i ~-~-ll I 1 ~I ! ; ca ;,t, - o _ ; _ _ ~ r L J i; ~ ~ LL tfs - I ~ _ 4 _ - ~ - i l4w.)uqej ND1S34 _tl vq auOlS Wqj `:Idf ! t i-~ z.- :u! i2 ! =1 1 i ~y i / (1.1~ uoiaE~uqLJ Ou015 1^J9l 7 7eS;an~ i awc )a iEf p C 1 t Z Y Y~.tT 1.-I V_, 77 C~ u) t 1 I N9IS3G I i uuUEJ!J4eJ'R ouo15 Van 1 qt f~ i it E~ F i gqq I l w9 .11f ruoell-tll 3 ugPd 'a'auolS yVlAl~-~;:nT tn._ w Pill! L a aF ~i Y f• ~t [~Y l 1 l I i 1 J~ cal r s Deparlm ntof JAN 0:3WIL EV LUATION REPORT #1902 $ and in accordance rith Comm 85. Wis. Adm. Code Page 1 of 5 F Safety s Professional Services _ Schmitt Soil I eshng, Inc ..sir art County Attach complete site plan on pa per iiotles sham , sin size. Plan must St. Croix include. but not limited to. vertical and honzogtal reference point (BM). direction and - percent slope. scale or dimensions, north arrow, and Dion IV disVnce 11p.learest road Parcel LD. Part of 1.76-1.08.6-40-001 print a Reviewed By Dale Please 74W6Y4M2DE8NW Personal mlormaeon you pilume may be used Property Owner Property Location Crane 1 Holdings LLC(Seller)/LBM Stone(B_ Govt. Lot SEVI SW114, S27, T29N, R18W r, r Property Owner's Mailing Address Lot If f Block If Subd. Name or CSM# v " 1505 Hwy 65 CW Pending ~IYS5Li I. City Stale Zip Code Phone Number City Village Town Nearest Road New Richmond WI, 54017 612-490-1037 Roberts 70Th Ave. New Construction Use. Residential i Number of bedrooms Code denved design flow rate GPD Replacement Public or commercial - Describe. Parent material Out wash Sand (Burkhardt-Sattre Series) Rood plain elevation. if applicable rl General comments Area is sui!abe fora mount system. System elevation is 47.20' based elf a contour line established at 95.86'. Slope of area s 2':. and recommendations depth to 6miling factor is 20'. L I ~ I, ' 'l, I } 'o ~ ;ne ^I. 11-4 ~ r3 te~,.i 1 ns Boring # Boring PA Ground surface elev 95.91 fl. Depth to limiting factor 20 m. Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPI in. Munsell Ou. Sz. Cont. Color Gi Sz Sh 'EN#t I "I 1 0-9 10yr3/3 none I 2fsbk mfr as 2vf 0.6 0.8 2 9-20 10yr4/3 none I lfsbk mfr gw 1vf 0.4 0.6 oft yr-612v sl lmsbk mfr gw 1vf 04 0.7 20-28 10yr4/4 7.S 612 m2d 7.5yr6/8 4 28-38 10yr5/6 - s Osg ml cs - - 0.7 1.6 7 .SVrtiR r m2d 7.5yrfi/8 5 38-56 10 r5/6 7.5Yr6i1 cos Osg ml 0.7 1.6 ti Water was seeping from the pit wall at 45. i Boring # Boring - Pd Ground surface elev. 95.91 _ it Depth to hmiLng factor 23 _ in Sod Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD Ill. Munsell Ou. Sz. Cont. Color Or. Sz Sh. *El -Fff#2 1 0-18 10yr3/3 none sil 2fsbk mfr gw 2vf 0.6 0.8 2 18-23 10yr4/4 none sit lfsbk mfr gw lvf 0.4 0.6 3 23-35 10yr4/6 7m2d. Syr6,r612 12 grscl 2msbk mfr 9tiv lwf0.4 _ - 0.6 4 35-56 10yr5/3 m7p 7.Syr6/8 sit lmsbk mfr 0.4 0.6 10Yr612 i, i C Water was seeping from the pt wall at 49". Effluent #1 = BOD,,, 30 220 mgI and TSS 130 < 150 irl ' Effluent #2 = BOD, < 30 mg/L and TSS < 30 mg/L CST Name (Please Print) Signature CST Number Thomas J Schmitt 227429 Address Schmitt Soil Testing, Inc. Date Evaluation Conducted Telephone Number 1595 72nd St. New Richmond, WI 54017 8/212017 715-760-1978 sen,cn,ik 171 Property Owner Crane 1 Holdings LLC(Seller)/LBM parcel ID # Part of: 176-1086-40-001 Page 2 of 5 Boring F Bonng # Pd Ground surface elev. 95.51 ft. Depth to limiting factor 21 m. 'Soil Application Rate HorfZorf Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPDV in. Munsell Ou. Sz. Cont. Color Gr. Sz Sh. -1`1101 -Elf#2 1 0-15 10yr3/3 none sil 2fsbk mfr as Ivf 0.6 0.8 2 15-21 1Oyr3/4 none sil 2fsbk mfr qw Ivf 0.6 0.8 I 3 2141 I0yr4/4 00/.5yr6/e I sit lfsbk mfr gw Ivf 0.4 0.6 7.Syrb ? m2d 7.5 r6/8 4 41-57 7.5yr4/4 1.5yr6/2 vfsl , lmsbk mfr 0.2 0.6 'il - - - - - 1 Water was seeping from the pit wall at 43". Boring F4 ]Boring # Pa Ground surface elev. 98.96 fl. Depth to limiting factor 84 in - - Soil Application Rale Horizon Depth Dominant Color Redox Description Texture Structure Consistences Boundary Roofs _ GPD/fI' _ in. Munsell Ou. Sz. Cant. Color Gr. Sz. Sh. l_ 'ufot •Ffhr2 -1 10yr3/ none L 2fsbk mfr as 2 0.6 1 0.8 i 1 - 1 - - I 9w 2vf 0.6 0.8 2 10-23 10yr3/4 none L 2fsbk mfr . 3 23-46 10yr4/6 none FSL lmsbk mfr cs lvf 0.2 0.6 4 46-84 10yr5/6 none S 0sq ml as 0.7 1 1.6 5 84-90 10yr5/6 "WATER" S I 0sg ml 0.7 1.6 .i Water was seeping from the pit wall A M". Boring rJ Boring # Pit 101.11 ft. Depth to limiting factor Ground surface elev. 92 is Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD..,W in Munsell Ou. Sz. Cont. Color Gr Sz. Sh. •Effvi •En#2 1 0-10 10yr3/3 none 1. 2fsbk mvfr as 2vf 0.6 0.8 2 110-18 10Yr4/3 none GRSI. 2fsbk mfr-- gw Ivf 0.6 1.0 3 18-30 7.5Yr4/6 none GRSL - - Lnsbk mfr gw Ivf 0.4 0.7 q 13044 7.5yr5/6 none GRCOS Osg I ml gw 0.7 1.6 5 44-92 7.5yr5/6 none GRCOS Osg ml j 0.7 1.6 i No water present to a depth of 92" Effluent #1 = BODE= 30 220 mgfL and fSS >:M 150 mg.L ' Fffluent #2 = BOD < 30 mgt and TSS <_30 mg .;L lli_ OcIm mcnl of Commerce. is an equal opportunity sere ice pro%idcr and emplocer. If you need assistance in access services or need material in :un alfrrnme fonnol. plcame onla,i the dcpurnnenl al 6ny-?6h-d l i t or I'll' fill-2(r1-8"'. property Owner Crane 1 Holdings LLC(Seller)/LBM Parcel ID # Part Of: 176-1086-40-001 Page 3 of 5 Boring 6 Boring # Pit Ground surface elev. 98.66 ft. Depth to limiting factor 82 in, - Soil Application Rate Horizon Depth Dominant Color ! Redox Description Texture Structure Consistence s Boundary Roots GPDE in Munsell Cu. Sz. Cont. Color Gr. Sz. Sh. T-1101 •Et42 1 0-8 10yr3/3 none L SIL 2fsbk mvfr as i Ivf 0.6 0.8 2 8 22 10yr4/4 _ none FSL III mfr qw 00.6 .2 ~ 00.6 3 22-40 7.5yr4/6 - 9w lvf i . 6 4 40-82 10yr5/6 I none COS Osg ml cs 0.7 1.6 5 82-92 10yr5/6 "WATER" COS Osg ml 0.7 1.6 Water was seeping from the pit wall at 84". Borng Boring # Pit Ground surface elev ft Depth to limiting factor in Soil Application Rate Horizon Depth Dominant Color Redox Description Texture Structure Consistence Boundary Roots GPD/it' in. Munsell Du. Sz. Cont. Color Gr. Sz Sh 'ER#1 •F no'; i i Boring Bonny # Pit Ground surface elev. 11 Depth to limiting factor in Soil Application Rate Horizon Depth Dornmant Color Redox Description Texture Structure Consistence Boundary Roots GPDtft' _ in. Munsell Du. Sz. Cont. Color Gr. Sz. Sh. 'Eif#1 •Ftr#2 i i ' Effluent #1 - 801), % 30 <220 ngll and rS S >30 <_150 mq4 ' Effluent #2 = BOD_ N mg:L and TSS <.30 mgIL 1 ht Depmlment or Commerce k an equal opportunilc sen ice provider and einplo•er. II'you need assistance to accfv >,'I ices or need m,ncrial in in allenrale Bernell, pleat eunt:rel t6c deptutmont ai 611#-I51 I I-I Y 6l1A-263-87 _ • / Conducted bY: Conducted For: Page Llof S Schmitt & Sons Excavating, Inc.. Name: Crane I Iloldings LLC Thomas J. Schmitt. CST 227429 Address: 1505 =Iwy 65 586 Valley View Trail City. State. Zip: New Richmond, wl 54017 Somerset, W 154025 Phone: 715-769-1978 PID: Part of: 176-1086-411-001 slgnaNV:_ Lot No owe -Av/J Legal Description SEV-1 tiW IA S27 T29N R18W ■ Backhoe Pit Township. County: Village of Roberts, St. Croix County ABench Mark 1 El. 100.00' Top of 2" PVC pipe AlRench Mark 2 El. 100.35' top of 2' PVC pipe . Slope= 2% Scale 1"= 60' Contour Line El. 95.86' Contour Line Length 75' 3 NOTE: For full view of Lot see Aerial Photo (Page 4 of 4) yam- o/ fgr8.8s ~ a sue' 33~ ~ t I x,.033 63 I .SLo E I 61 VS I Bs 160 ■ yon : rlo' Sip I t I ' I a~ 9b I ~ i dml pmt we 7 sr Aws z a - z m cn m m _g 0 C/) ,a Oo c„ j w „1 + 1 4- 74 0 r O TWO- z m x m cn o m